# 2025-13188: Patton Mining Wants a Different Way to Meet Safety Rules

2025-13188, Petition for Modification of Application of Existing Mandatory Safety Standards, is a Federal Register notice from Labor Department, Mine Safety and Health Administration published 2025-07-15, effective All comments on the petition must be received by MSHA's Office of Standards, Regulations, and Variances on or before August 14, 2025.; PRIA reads it as touching household money (as of 2026-11-12).

- Canonical: https://policyrisk.com/federal-register/2025-13188
- As of: 2026-11-12
- Plain-text twin of the page above; the HTML and this file carry the same facts.

## Facts
- Document number: 2025-13188
- Title: Petition for Modification of Application of Existing Mandatory Safety Standards
- Type: Notice
- Agencies: Labor Department; Mine Safety and Health Administration
- Citation: 90 FR 31698
- Published: 2025-07-15
- Effective: All comments on the petition must be received by MSHA's Office of Standards, Regulations, and Variances on or before August 14, 2025.
- Comments close: not stated
- Significant: no
- Touches household money: yes
- Regulation identifier numbers: none
- Last updated: 2026-11-12

## In one line

Patton Mining Wants a Different Way to Meet Safety Rules

## Summary

Patton Mining, LLC asked to change some safety rules at their mine to use a different way that keeps miners just as safe. This could affect how safety checks are done but won’t cost extra money or reduce protection. Everyone has until August 14, 2025, to share their thoughts with the Mine Safety and Health Administration.

## Abstract

This notice is a summary of a petition for modification submitted to the Mine Safety and Health Administration (MSHA) by Patton Mining, LLC.

## Effects PRIA read

- Allow longer 995-volt shuttle car cables: benefit, low. Patton Mining asked MSHA to allow trailing cables that supply three-phase, 995-volt power to shuttle cars to be up to 950 feet long and to require those cables be at least #2 AWG. The request applies to Deer Run Mine (MSHA ID No. 11-03182) and would specifically cover 995-volt shuttle car trailing…
- New overcurrent settings, labeling, and password protection: benefit, low. The petition would require use of a Schweitzer Engineering Laboratories SEL-75 lA overcurrent protection relay with password-protected settings, set instantaneous trip units on breakers protecting #2 AWG trailing cables over 700 feet to trip at 800 amperes, and keep those settings password protecte…
- Daily cable inspections, repair standards, and required training: benefit, low. The petitioner would require designated persons to visually examine trailing cables each production day and remove any cable not in safe condition for repair or replacement; all splices/repairs must follow manufacturer instructions and comply with 30 CFR 75.603 and 75.604. Before using the alternat…

## Related documents

- [2026-15717](https://policyrisk.com/federal-register/2026-15717): Ventilation Plan Approval Criteria, 2026-08-03
- [2026-15670](https://policyrisk.com/federal-register/2026-15670): Roof Control Plan Approval Criteria, 2026-08-03
- [2026-10456](https://policyrisk.com/federal-register/2026-10456): Department of Labor Federal Civil Penalties Inflation Adjustment Act Annual Adjustments for 2026, 2026-05-27
- [2025-12232](https://policyrisk.com/federal-register/2025-12232): Ventilation Plan Approval Criteria, 2025-07-01
- [2026-21213](https://policyrisk.com/federal-register/2026-21213): Affirmative Decisions on Petitions for Modification Granted in Whole or in Part, 2026-10-16
- [2026-21175](https://policyrisk.com/federal-register/2026-21175): Petition for Modification of Application of Existing Mandatory Safety Standards, 2026-10-16

## Sources
- [2025-13188 on federalregister.gov](https://www.federalregister.gov/documents/2025/07/15/2025-13188/petition-for-modification-of-application-of-existing-mandatory-safety-standards)
- [2025-13188 as published (PDF)](https://www.govinfo.gov/content/pkg/FR-2025-07-15/pdf/2025-13188.pdf)

## Related
- [Previous: 2025-13187, Petition for Modification of Application of Existing Mandatory Safety Standards](https://policyrisk.com/federal-register/2025-13187)
- [Next: 2025-13189, Petition for Modification of Application of Existing Mandatory Safety Standards](https://policyrisk.com/federal-register/2025-13189)
- [All Federal Register documents](https://policyrisk.com/federal-register)

Source: PRIA, https://policyrisk.com/federal-register/2025-13188 (as of 2026-11-12).