2025-13181NoticeWallet

Mine Wants Special Powered Air Respirators in Place of Usual Gear

Published Date: 7/15/2025

Notice

Summary

Mach Mining, LLC wants to change a safety rule about electric gear at their Mach #1 Mine in Illinois. They’re asking to use special safe-powered air respirators instead of the usual equipment to keep miners safe. Comments on this change must be sent by August 14, 2025, so everyone has time to weigh in before any money or safety impacts happen.

Analyzed Economic Effects

5 provisions identified: 4 benefits, 1 costs, 0 mixed.

Request to Allow PAPRs within 150 Feet

Mach Mining, LLC requests permission to use intrinsically safe Powered Air Purifying Respirators (PAPRs) — specifically the CleanSpace EX and the 3M Versaflo TR-800 — as an alternative respirable-dust protection method within 150 feet of pillar workings or longwall faces at Mach #1 Mine.

Battery, Charging, and Charger Restrictions

The petitioner proposes several battery and charging limits: the 3M Versaflo TR-800 must use only the 3M TR-830 battery pack or manufacturer equivalent; TR-830 battery packs must be charged only on the surface and only with specified chargers (3M TR-641N or TR-644N or equivalent); CleanSpace EX batteries must be charged on the surface or underground in intake air and not within 150 feet of pillar workings or longwall faces using specified chargers (PAF-0066, PAF-1100 or equivalent); spare battery change-outs for the TR-800 must occur in intake air, not within 150 feet of pillar workings or longwall faces; and battery packs must be disposed of once performance decreases by greater than 20 percent.

Weekly Equipment Examinations and Records

The petitioner proposes that the PAPRs be examined at least weekly by a qualified person per 30 CFR 75.512-2, that examination results be recorded weekly, and that those records may be expunged after one year.

Training Requirement Before Use

Before using the CleanSpace EX or 3M Versaflo TR-800 PAPRs in the relevant part of the mine, miners must receive training on safe use, care, inspection of the PAPR, and on the Proposed Decision and Order; a record of the training must be kept and available upon request.

Methane Monitoring and 1.0% Threshold

The petitioner proposes that if methane is detected in concentrations of 1.0 percent or more, procedures in accordance with 30 CFR 75.323 be followed, and that a qualified person under 30 CFR 75.151 shall monitor for methane in the affected area of the mine as required by the standard.

Personalized for You

How does this regulation affect your finances?

Personalize government policy and PRIA will tell you what this federal register document means for your household, plus every other regulation we track. PRIA reads each provision against your financial profile to show you exactly what matters to your wallet.

Key Dates

Published Date
7/15/2025

Department and Agencies

Department
Independent Agency
Agency
Labor Department
Mine Safety and Health Administration
Source: View HTML

Related Federal Register Documents

Previous / Next Documents

Back to Federal Register