69A-21-.103 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
3.2K chars
(1) The applicant shall submit an application on a form furnished by the Regulatory Licensing Section which shall conform with section 633.304, F.S., Form DFS-K3-31, "Application for Fire Equipment Permit," revised and dated 11/99, which is incorporated herein by reference, which…
69A-21-.104 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
4.7K chars
(1) The prescribed certification training course shall be taken at the Florida State Fire College in Ocala or at another facility approved as provided in subsection (3). (2) The procedures regarding the certification course at the Florida State Fire College or at another approved…
69A-21-.106 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.3K chars
A fire equipment dealer license is not transferable to another person or business organization. Any individual who wishes to change company affiliation must comply with section 633.304, F.S. Rulemaking Authority 633.104 FS. Law Implemented 633.304 FS. History-New 2-7-89, Amended …
69A-21-.107 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.3K chars
A fire equipment permit is not transferable to another person or business organization. Any individual who wishes to change company affiliation must comply with section 633.304, F.S. Rulemaking Authority 633.104 FS. Law Implemented 633.304 FS. History-New 2-7-89, Amended 10-20-93…
69A-21-.112 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.3K chars
The insurance requirements for a fire equipment dealer subject to subparagraph 633.304(4)(d)3., F.S., are set at $300,000 for Class A or Class D licensees, $200,000 for Class B licensees, and $100,000 for Class C licensees. Rulemaking Authority 633.304(4)(d)3. FS. Law Implemented…
69A-21-.113 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
8.6K chars
(1) Licenseholders and permitholders shall complete a continuing education course or combination of courses in compliance with section 633.304, F.S., for each permit held. (2) The continuing education course or combination of courses shall be related to the scope of each license …
69A-21-.114 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.1K chars
Rulemaking Authority 633.104 FS. Law Implemented 633.304 FS. History-New 10-20-93, Amended 11-21-01, Formerly 4A-21.114, Repealed 10-8-14.
69A-21-.115 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
1.0K chars
"Appropriate training" as used in section 633.304(1), F.S., for the purpose of servicing fire extinguishers and preengineered systems means: (1) Any training specific to the servicing of the fire extinguisher or preengineered system provided by the manufacturer of the fire exting…
69A-21-.201 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.5K chars
The provisions of Part II of this chapter shall apply to licensed fire equipment dealers when installing, maintaining, recharging or otherwise servicing portable extinguishing equipment, and other portable devices for fire extinguishment, excluding pre-engineered fire protection …
69A-21-.203 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.7K chars
Licensed fire equipment dealers are required to install, inspect, maintain, or recharge portable fire extinguishers in accordance with NFPA 10, Standard for Portable Fire Extinguishers, the edition as adopted in rule chapter 69A-3, F.A.C. The provisions of NFPA 10, the edition as…
69A-21-.237 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
1.9K chars
(1) Annual maintenance shall be in accordance with the provisions of NFPA 10, as adopted in rule 69A-21.203, F.A.C., and the manufacturers maintenance manuals. The extinguishers listed in the Exception in section 4-4.2 shall be weighed by accurate scales which have been tested wi…
69A-21-.238 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.4K chars
No licenseholder shall remove or permit any of his or her employees to remove any in-service fire extinguisher from its designed location for maintenance purposes without first meeting the requirements of NFPA 10, the edition as adopted in rule chapter 69A-3, F.A.C. Rulemaking Au…
69A-21-.240 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.9K chars
Each portable extinguisher which has been subjected to any type of service shall have an approved standard record tag securely attached thereto, before being placed into service. Standard service tags shall not be attached to fire extinguishers which do not comply with this rule …
69A-21-.241 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
2.5K chars
(1) Service Tags, Annual Maintenance. (a) Approved standard service tags shall meet the following specifications and shall be arranged as indicated in Figure "A." In lieu of using the standard "tie-on" type service tag, a pressure sensitive label or decal meeting the same specifi…
69A-21-.242 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
1.1K chars
Hydrostatic tests shall be conducted in accordance with the procedures in NFPA 10, as adopted in Rule Chapter 69A-3, F.A.C., and the portions of 49 Code of Federal Regulations, Parts 100-177 which are referenced in Compressed Gas Association CGA C-1-1996, Methods for Hydrostatic …
69A-21-.245 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
1.2K chars
The hydrostatic test record tag shall comply with the requirements of NFPA 10 as adopted in rule chapter 69A-3, F.A.C., and the portions of 49 Code of Federal Regulations, Parts 100-177, which are referenced in Compressed Gas Association CGA C-1-1996, Methods for Hydrostatic Test…
69A-21-.249 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.5K chars
The leak test shall be performed by following the manufacturer's recommendations. Any tamper indicators or seals shall be replaced each year and after each recharge of a portable fire extinguisher. Tamper indicator pull pressure or break pressure shall not exceed 15 pounds. Rulem…
69A-21-.251 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.7K chars
Invoices shall include the business name, physical business address and license number of the fire equipment dealer. The license number on the invoice shall coincide with the permit number on the tags which are attached to the extinguishers being invoiced for service. Invoices fo…
69A-21-.301 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.3K chars
The provisions of Part III of this chapter shall apply to licensed fire equipment dealers when installing, maintaining, recharging, or otherwise servicing pre-engineered systems. Rulemaking Authority 633.104 FS. Law Implemented 633.104 FS. History-New 10-18-67, Formerly 4A-21.56,…
69A-21-.302 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
1.0K chars
The following standards of the National Fire Protection Association as adopted in rule chapter 69A-3, F.A.C., are applicable to part III of this rule chapter and shall be complied with and are hereby adopted and incorporated by reference: (1) NFPA 12, Standard on Carbon Dioxide E…
69A-21-.303 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
1.4K chars
(1) A standard service tag shall be affixed to pre-engineered fire protection systems when the system is found to be in compliance with chapter 633, F.S., this rule and the standards adopted pursuant to rule chapter 69A-3, F.A.C. The standard service tag on a pre-engineered fire …
69A-21-.304 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
2.7K chars
(1) All pre-engineered systems are to be inspected in accordance with the standards adopted in rule 69A-21.302, F.A.C. (2) Whenever a pre-engineered system is installed, inspected, repaired, maintained or otherwise serviced, the permittee shall complete an inspection report conta…
69A-21-.401 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.7K chars
The purpose of Part IV of this chapter is to establish procedures by which laboratories engaged in testing and listing portable fire extinguishers or pre-engineered systems may be considered a "nationally recognized testing laboratory" for purposes of sections 633.306(1)(b), 633.…
69A-21-.402 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
0.8K chars
(1) The applicant testing laboratory shall comply in general with the definitions and requirements contained in subsection 69A-3.009(9), F.A.C., and 29 CFR 1910.7, dated July 1, 1992, which is hereby adopted and incorporated by reference. (2) The applicant laboratory shall mainta…
69A-21-.403 FIRE EXTINGUISHERS AND PRE-ENGINEERED SYSTEMS
4.7K chars
(1) The application by a testing laboratory for recognition by the State Fire Marshal as a "nationally recognized testing laboratory" shall not be on any particular form but shall include all of the information and material requested in subsection (2), below. (2)(a) The address a…
69A-3-.009 FIRE PREVENTION - GENERAL PROVISIONS
4.1K chars
Unless otherwise provided for by statute or the NFPA, the following terms shall, for the purpose of these rules, have the meanings indicated in this rule: (1) "Approved" means accepted by the authority having jurisdiction upon evaluation of compliance with appropriate standards f…
69A-3-.011 FIRE PREVENTION - GENERAL PROVISIONS
2.2K chars
(1) Special definitions. (a) "Annually" means once at any time during the fiscal year July 1 through June 30. (b) "Three or more floor levels" shall mean the sum of all levels of exit discharge plus levels above and below the exit discharge, including basements. (c) "Recurring ba…
69A-3-.012 FIRE PREVENTION - GENERAL PROVISIONS
22.8K chars
(1) Except as specifically modified by statute or by the State Fire Marshal's rules, the "Florida Fire Prevention Code, 8th Edition (2023)," which is comprised of the Florida specific edition of NFPA 101, the Life Safety Code® Florida 2021 Edition and NFPA 1, the Fire Code Florid…
69A-36-.100 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
0.6K chars
The purpose of this rule chapter is to specify, as required by the Florida Statutes, uniform fire safety standards for both new and existing Nonresidential Child Care Facilities designed to care for infants and children, ages 0 through 17 years, for a period of less than 24 hours…
69A-36-.101 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
0.3K chars
This rule chapter shall apply to both new and existing buildings used as Nonresidential Child Care Facilities. Rulemaking Authority 633.104, 633.206 FS. Law Implemented 402.305, 633.104(1), 633.206(1)(b) FS. History-New 3-23-88, Amended 10-10-91, 7-11-01, Formerly 4A-36.101.
69A-36-.102 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
0.5K chars
Ratios of staff personnel to children for both new and existing facilities shall be those ratios established by the Florida Department of Children and Family Services as required by section 402.305(4), F.S., and as adopted pursuant thereto by the rules of the Florida Department o…
69A-36-.103 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
0.4K chars
For both new and existing facilities the occupant load for which means of egress shall be provided for any floor shall be those established in section 402.305(6), F.S. The occupancy load referenced in NFPA 101 does not apply. Rulemaking Authority 633.104, 633.206 FS. Law Implemen…
69A-36-.105 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
1.5K chars
(1) The standards of the National Fire Protection Association for life safety from fire, as provided in NFPA 101, Life Safety Code, as adopted in rule 69A-3.012, F.A.C., and incorporated herein by reference shall be the Uniform Fire Safety Standards for Nonresidential Child Care …
69A-36-.106 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
2.0K chars
(1) New Child Day Care Facilities shall be arranged to transmit the alarm automatically via any of the following means acceptable to the authority having jurisdiction and shall be in accordance with NFPA 72, National Fire Alarm Code, the edition as adopted in rule 69A-3.012, F.A.…
69A-36-.107 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
0.4K chars
Standpipe systems shall be provided for all buildings over 50 feet in height, except buildings not over 6 stories high which are equipped with a complete automatic sprinkler system, in accordance with NFPA 13, as adopted in rule 69A-3.012, F.A.C. Rulemaking Authority 633.104, 633…
69A-36-.108 UNIFORM FIRE SAFETY STANDARDS FOR NONRESIDENTIAL CHILD CARE FACILITIES
0.7K chars
The subclassifications and definitions of "Day Care Homes" as set forth in Section 16.6.1.4.1 and 17.6.1.4.1 of NFPA 101 2000 Edition, to wit, "Family Day Care Homes," and "Group Day Care Homes," shall not apply to any facility licensed as a family day care home pursuant to secti…
69A-37-.020 FIREFIGHTERS STANDARDS AND TRAINING
1.0K chars
(1) Pursuant to Section 633.138, F.S., any individual who is issued a license, permit, or certificate shall notify the Division of any change to her or his current mailing address, email address and place of practice. Any change to a current mailing address, email address or plac…
69A-37-.0335 FIREFIGHTERS STANDARDS AND TRAINING
0.5K chars
(1) Any person applying for employment as a firefighter must meet all the requirements of Section 633.412, F.S. (2) Upon the employment of a firefighter, the employing agency shall report such employment to the Bureau of Fire Standards and Training (hereinafter the "Bureau") with…
69A-37-.0336 FIREFIGHTERS STANDARDS AND TRAINING
1.3K chars
(1) An applicant shall make application for a certificate of compliance on form DFS-K4-1016, effective January 1, 2009, adopted and incorporated by reference in subsection 69A-37.039(2), F.A.C. The form can be obtained where indicated in subsection 69A-37.039(1), F.A.C. The appli…
69A-37-.034 FIREFIGHTERS STANDARDS AND TRAINING
1.6K chars
(1) Pursuant to Section 633.408(4), F.S., the high school education requirement of Section 633.412(1), F.S., must be met prior to receiving a certificate of compliance as a firefighter. (2) The Division of State Fire Marshal, Bureau of Fire Standards and Training shall consider a…
69A-37-.036 FIREFIGHTERS STANDARDS AND TRAINING
0.8K chars
(1) Applicants for a certificate of compliance as a firefighter shall submit fingerprints for the purpose of conducting a criminal background check. Determination of good moral character is required prior to certification as a firefighter pursuant to Sections 633.412(4) and 633.4…
69A-37-.037 FIREFIGHTERS STANDARDS AND TRAINING
2.3K chars
(1) Pursuant to Section 633.412(5), F.S., an individual must be in good physical condition evidenced by a medical examination in order to gain admission into a firefighter training program. Proof of such a medical examination evidencing good physical condition must be submitted t…
69A-37-.0385 FIREFIGHTERS STANDARDS AND TRAINING
0.6K chars
Upon the termination of employment of a firefighter, the employing agency shall forward to the Bureau of Fire Standards and Training a completed Form DFS-K4-1033, entitled "Notice of Termination of Employment as a Firefighter (Rev. 3-01)." This form shall be forwarded within ten …
69A-37-.039 FIREFIGHTERS STANDARDS AND TRAINING
9.2K chars
(1) Information required by the Bureau in this chapter shall be furnished on-line at www.floridastatefirecollege.org. The information required at www.floridastatefirecollege.org is based on prescribed forms set forth below and incorporated herein. The forms can also be obtained: …
69A-37-.050 FIREFIGHTERS STANDARDS AND TRAINING
0.2K chars
Rulemaking Authority 633.128(2)(a) FS. Law Implemented 633.128(1)(e), 633.406, 633.412, 633.408 FS. History-New 9-7-81, Formerly 4A-37.13, 4A-37.50, Amended 11-26-85, 1-3-90, 3-20-95, 12-10-01, Formerly 4A-37.050, Repealed 6-4-14.
69A-37-.0527 FIREFIGHTERS STANDARDS AND TRAINING
8.3K chars
(1) Section 633.414, F.S., which took effect on July 1, 2013, requires firefighters to meet certain requirements every 4 years in order to retain their firefighter certificates of compliance. (a) For the purpose of this rule, "certification," or "certified," shall have the same m…
69A-37-.054 FIREFIGHTERS STANDARDS AND TRAINING
7.7K chars
(1) Out of State Firefighter Certificate of Compliance. (a)1. An individual who has satisfactorily completed training for firefighters in another state and seeks a Firefighter Certificate of Compliance shall submit: a. A completed Form DFS-K4-1309 "Firefighter Equivalency Examina…
69A-37-.055 FIREFIGHTERS STANDARDS AND TRAINING
6.4K chars
(1) Overview. The firefighter training curriculum requirements for schools operated by or for any employing agency for the specific purpose of training firefighter recruits or firefighters consist of 191 hours of training to complete Part I (equivalent to National Fire Protection…
69A-37-.056 FIREFIGHTERS STANDARDS AND TRAINING
5.3K chars
(1) To be recognized for certification as a firefighter by the Bureau, training must be obtained under the conditions specified herein. A designated instructor or member of the Bureau staff must certify a firefighter has completed the prescribed training, instruction, and standar…
69A-37-.057 FIREFIGHTERS STANDARDS AND TRAINING
1.0K chars
During the first week of training for the Minimum Standards Course, a roster of students shall be electronically forwarded to the Bureau, with all supporting paperwork (i.e., release of a building to burn, if applicable; any required affidavits for use of other facilities or equi…