Sec. 45.43

225 ILCS 710/45.43 — under Fluorspar Mines Act.

225 ILCS 710/45.43

(225 ILCS 710/45.43) (from Ch. 96 1/2, par. 4296)

Sec. 45.43.

Winzes opening directly from the floor of a drift or stope shall be kept covered by a substantial hatch, or shall be planked over, except when in use, or shall be barred off by a substantial railing not less than 3 1/2 feet nor more than 4 feet above the level of the floor, or shall be provided with a gangway not less than 10 inches wide, which gangway shall have a substantial hand railing not less than 3 1/2 feet nor more than 4 feet above the gangway, and the approaches to such gangway at either end shall be protected by a substantial railing not less than 3 1/2 feet nor more than 4 feet above the floor.

(Source: Laws 1945, p. 1035.)