54,212 sections across 3,422 New Mexico regulatory chapters.
R.14.6.6-14.6.6.3 STATUTORY AUTHORITY
0.0K chars
Section 60-13 -9 NMSA 1978.
R.14.6.6-14.6.6.4 DURATION
0.0K chars
Permanent.
R.14.6.6-14.6.6.5 EFFECTIVE DATE
0.1K chars
March 10, 2022, unless a later date is cited at the end of a section.
R.14.6.6-14.6.6.6 OBJECTIVE
0.1K chars
The objective of this rule is to set forth the classifications of licenses and certificates issued by CID.
R.14.6.6-14.6.6.7 DEFINITIONS
0.1K chars
See Section 60-13-3 NMSA 1978 and 14.5.1.7 NMAC for definitions.
R.14.6.6-14.6.6.8 GENERAL INFORMATION
2.4K chars
A. Any license issued pursuant to the CILA and Title 14 NMAC authorizes contracting only in the scope of work authorized by the classification(s) of the issued license . Work performed outside that scope constitutes a violation of the CILA and its rules and constitutes grounds fo…
R.14.6.6-14.6.6.9 GENERAL CONSTRUCTION CLASSIFICATIONS
19.2K chars
A. GA. Asphalt, bitumen and concrete construction: Applies to surfaces used by vehicular traffic, not airborne craft; construction or maintenance of unpaved private rural roads or rural unpaved parking areas that are located on private property not intended for use by the general…
R.14.6.7-14.6.7.1 ISSUING AGENCY
0.1K chars
The Construction Industries Division (CID) of the Regulation and Licensing Department (RLD).
R.14.6.7-14.6.7.10 REGISTRATION FOR IN-PLANT INSPECTION AGENCIES
1.4K chars
A. Applicant for registration pursuant to this part shall submit the following: (1) A completed and approved registration application. (2) A fee of $300.00. (3) Proof of authorization to conduct business in the state of New Mexico if performing work within the state. (4) Proof of…
R.14.6.7-14.6.7.11 IN-PLANT INSPECTOR
2.1K chars
All in-plant inspectors for modular production whether modular structure or modular component production for use in New Mexico must be approved by the division. An inspector shall be approved by the division trade bureau chief for the trade to be inspected. Any approved in-plant …
R.14.6.7-14.6.7.12 MODULAR PROCEDURES
4.1K chars
Any modular structure manufactured in New Mexico, or to be shipped into New Mexico for installation, must comply with the following provisions. A manufacturer can be removed as an approved manufacturer for cause by the director. A. Plan review: (1) Two sets of modular structure d…
R.14.6.7-14.6.7.13 INSTALLATION OF MODULAR STRUCTURES
3.4K chars
A. The division or the AHJ shall verify that the unit has both the compliance decal and the data plate properly attached. B. Each modular structure to be permanently installed within the state of New Mexico shall be installed in accordance with all applicable statutes, codes, rul…
R.14.6.7-14.6.7.14 EXCEPTIONS TO MODULAR REQUIREMENTS
1.4K chars
A. A modular structure that carries a UL, ANSI or other approved testing laboratory's label as a rated assembly shall be exempt from the provisions of 14.6.7 NMAC when recommended by the appropriate trade bureau chiefs and approved by the director. However there shall be mandator…
R.14.6.7-14.6.7.15 PROHIBITED USES AND OCCUPANCY OF CONVERTED STRUCTURES
1.1K chars
A. If not covered by Subsection A of 14.6.7.14 NMAC, storage sheds and similar structures shall not be used as a dwelling unless the structure has been subject to plan review, permitting, inspection(s) and constructed or altered in a manner that is compliant with all code require…
R.14.6.7-14.6.7.16 DISCIPLINE
0.1K chars
Each violation of the modular building regulations or of the CID Licensing Act is subject to discipline.
R.14.6.7-14.6.7.17 TEMPORARY INSTALLATION
0.4K chars
A. Modular units may be installed on a temporary foundation for a period of up to one year. Units installed as temporary and remaining in place after the one-year period must be placed on a permanent foundation and comply with all modular requirements. B. Modular units installed …
R.14.6.7-14.6.7.18 MODULAR ASSEMBLED COMPONENTS
0.3K chars
A. Modular non-assembled component panels shall meet all the requirements of this rule with the exception of Paragraph (2) of Subsection B of 14.6.7.12 NMAC and 14.6.7.13 NMAC. B. Assembly of component panels on site are subject to all building permitting and inspection requireme…
R.14.6.7-14.6.7.2 SCOPE
0.1K chars
The construction, alteration, repair, use and occupancy of modular structures in the state of New Mexico.
R.14.6.7-14.6.7.3 STATUTORY AUTHORITY
0.3K chars
These standards are adopted pursuant to Subsections L and M of Section 60-13-2, Subsections F and K of Section 60-13-9, Section 60-13-10, Subsection H of 60-13-41, Subsection E of Section 60-13-42 and Subsections H and I of Section 60-13-44 of the Construction Industries Licensin…
R.14.6.7-14.6.7.4 DURATION
0.0K chars
Permanent.
R.14.6.7-14.6.7.5 EFFECTIVE DATE
0.1K chars
July 1, 2018, unless a later date is cited at the end of a section.
R.14.6.7-14.6.7.6 OBJECTIVE
0.3K chars
The purpose of this rule is to promote the general welfare of the people of New Mexico by providing for the protection of life and property through construction codes, rules, and standards, the compliance with which will result in safer modular structure.
R.14.6.7-14.6.7.7 DEFINITIONS
5.9K chars
The following terms shall have the meaning indicated when used in this rule. A. "Act" means the Construction Industries Licensing Act, Sections 60-13-1 through 60-13-59 NMSA 1978 and the LP Gas Act, Sections 70-5-1 through 70-5-23 NMSA 1978. B. "Approved In-plant Inspector List" …
R.14.6.7-14.6.7.8 APPLICABLE CODES AND STANDARDS
0.2K chars
The codes set forth in Title 14 Chapters 5 through 10 NMAC are the standards applicable to the construction, alteration, repair, use, occupancy and installation of modular structures and modular components.
R.14.6.7-14.6.7.9 REGISTRATION FOR MODULAR MANUFACTURERS
3.5K chars
All manufacturers of modular products must be registered with the division. A. Applicants for registration pursuant to this part shall submit the following: (1) A division approved registration application. (2) A Fee of $300.00 per three year licensing cycle. (3) Proof of the res…
R.14.7.2-14.7.2.1 ISSUING AGENCY
0.1K chars
Construction Industries Division (CID) of the Regulation and Licensing Department.
R.14.7.2-14.7.2.10 CHAPTER 2 - DEFINITIONS
2.4K chars
See this section of the IBC except as provided below. A. Section 201 - General. See this section of the IBC except as provided as provided below. (1) Section 201.1 - Scope. See this section of the IBC except add the following: If the same term is defined in the New Mexico constru…
R.14.7.2-14.7.2.11 CHAPTER 3 - OCCUPANCY CLASSIFICATION AND USE
0.8K chars
See this chapter of the IBC except as provided below. A. Section 304 - Business Group B. See this section of the IBC except as provided below. Section 304.1 - Business Group B. See this section of the IBC and add the following to the list: Fire stations and police stations. B. Se…
R.14.7.2-14.7.2.12 CHAPTER 4 - SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
0.2K chars
See this chapter of the IBC with the following exception: For Sections 404.1 through 404.11, the definition of the term "ATRIUM", is amended to substitute the words "floor levels" for the word "stories".
R.14.7.2-14.7.2.13 CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS
1.4K chars
See this chapter of the IBC except as provided below. Section 504 - Building Height and Number of Stories. See this section of the IBC except as provided below. A. Section 504.1 - General. See this section of the IBC except as provided below. Add the following section: 504.1.3 - …
R.14.7.2-14.7.2.14 CHAPTER 6 - TYPES OF CONSTRUCTION
0.7K chars
See this chapter of the IBC except as provided below. Section 603 - Combustible Material in Types I and II Construction. See this section of the IBC except as provided below. Section 603.1 - Allowable materials. Add the following exceptions to subsection 2:Exception 28. Stairways…
R.14.7.2-14.7.2.15 CHAPTER 7 - FIRE AND SMOKE PROTECTION FEATURES
0.2K chars
See this chapter of the IBC except as provided below. Section 708.4.2 - Fireblocks and draftstops in combustible construction. See this section of the IBC except delete Exception 2.
R.14.7.2-14.7.2.16 CHAPTER 8 - INTERIOR FINISHES
0.0K chars
See this chapter of the IBC.
R.14.7.2-14.7.2.17 CHAPTER 9 - FIRE PROTECTION SYSTEMS
1.7K chars
See this chapter of the IBC except as provided below. A. Section 903 - Automatic Sprinkler Systems. See this section of the IBC except as provided below. Section 903.2 - Where required. See this section of the IBC except delete the exception. B. Section 909 - Smoke Control System…
R.14.7.2-14.7.2.18 CHAPTER 10 - MEANS OF EGRESS
2.7K chars
See this chapter of the IBC except as provided below. A. Section 1004 - Occupant Load. See this section of the IBC except as provided below. Table 1004.5 - Maximum floor area allowances per occupant. See this table of the IBC and amend as follows: under the function of space colu…
R.14.7.2-14.7.2.19 CHAPTER 11 - ACCESSIBILITY
7.1K chars
See this chapter of the IBC except as provided below. A. Section 1102 - Compliance. See this section of the IBC except as provided below. Section 1102.1 Design. Delete this section of the IBC except and substitute with the following: Building and facilities shall be designed and …
R.14.7.2-14.7.2.2 SCOPE
1.1K chars
This rule applies to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, removal and demolition of every building or structure or any appurtenances connected or attached to such building or structure performed in New…
R.14.7.2-14.7.2.20 CHAPTER 12 - INTERIOR ENVIRONMENT
0.0K chars
See this chapter of the IBC.
R.14.7.2-14.7.2.21 CHAPTER 13 - ENERGY EFFICIENCY
0.1K chars
Delete this chapter of the IBC and see NMAC 14.7.9, New Mexico Commercial Energy Conservation Code.
R.14.7.2-14.7.2.22 CHAPTER 14 - EXTERIOR WALLS
0.0K chars
See this chapter of the IBC.
R.14.7.2-14.7.2.23 CHAPTER 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
2.4K chars
See this chapter except as provided below: A. Section 1503 - Weather Protection. See this section of the IBC except as provided below. (1) Section 1503.3 - Parapet walls. Delete this section and replace with the following: Parapet walls shall be coped or covered in accordance wit…
R.14.7.2-14.7.2.24 CHAPTER 16 - STRUCTURAL DESIGN
0.0K chars
See this chapter of the IBC.
R.14.7.2-14.7.2.25 CHAPTER 17 - SPECIAL INSPECTIONS AND TESTS
1.3K chars
See this chapter of the IBC except as provided below. A. Section 1705.3 - Concrete Construction. See this section of the IBC except as provided below. (1) Subsection 2 - Delete this section of the IBC and substitute: continuous concrete footings supporting walls of buildings thre…
R.14.7.2-14.7.2.26 CHAPTER 18 - SOILS AND FOUNDATIONS
1.4K chars
See this chapter of the IBC except as provided below. Section 1809 - Shallow Foundations. See this section of the IBC except as provided below. A. Section 1809.7 - Prescriptive footings for light-frame construction. Delete this section of the IBC and substitute with the following…
R.14.7.2-14.7.2.27 CHAPTER 19 - CONCRETE
0.9K chars
See this chapter of the IBC except as provided below. A. Section 1906 Footings for Light-Frame Construction. Delete this section of the IBC with no substitution. B. Section 1907 Minimum Slab Provisions. See this section of the IBC except as provided below. Section 1907.1 General.…
R.14.7.2-14.7.2.28 CHAPTER 20 - ALUMINUM
0.0K chars
See this chapter of the IBC.
R.14.7.2-14.7.2.29 CHAPTER 21 - MASONRY
2.1K chars
See this chapter of the IBC except as provided below. A. Section 2111 - Masonry Fireplaces. See this section of the IBC except as provided below. Section 2111.5 - Seismic Anchorage. Delete this section of the IBC and substitute with the following: Two three-sixteenth-inch by one-…
R.14.7.2-14.7.2.3 STATUTORY AUTHORITY
0.1K chars
Sections 60-13-9, 60-13-10.3 and 60-13-44 NMSA 1978.
R.14.7.2-14.7.2.30 CHAPTER 22 - STEEL
0.0K chars
See this chapter of the IBC.
R.14.7.2-14.7.2.31 CHAPTER 23 - WOOD
0.7K chars
See this chapter of the IBC except as provided below. Section 2308 - Conventional Light-Frame Construction. See this section of the IBC except as provided below. A. Section 2308.4.5 - Joists supporting bearing partitions. See this section of the IBC except delete the first senten…