278 sections in this chapter.
25 Pa. Code Ch. 208 § 208.47 Emergency response plan; refuge alternatives
0.2K chars
§ 208.47. Emergency response plan; refuge alternatives. The provisions of 30 CFR 75.1507 (relating to Emergency Response Plan; refuge alternatives) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.48 Training and records for examination, maintenance and repair of refuge alternatives and components
0.3K chars
§ 208.48. Training and records for examination, maintenance and repair of refuge alternatives and components. The provisions of 30 CFR 75.1508 (relating to training and records for examination, maintenance and repair of refuge alternatives and components) are incorporated by refe…
25 Pa. Code Ch. 208 § 208.51 Communications facilities for refuge alternatives
0.2K chars
COMMUNICATIONS § 208.51. Communications facilities for refuge alternatives. The provisions of 30 CFR 75.1600-3 (relating to communications facilities; refuge alternatives) are incorporated by reference.
R.208.600 Sensitive ground fault
2.3K chars
CABLE SAFETY § 208.600. Sensitive ground fault. All three-phase electrically operated equipment operated on a working section inby the last open crosscut must receive power from a circuit equipped with a sensitive ground fault protection as specified in this section. (1) Sensitiv…
25 Pa. Code Ch. 208 § 208.61 Availability of approved self-contained self-rescue devices; instruction in use and location
0.3K chars
SELF-CONTAINED SELF-RESCUE DEVICES § 208.61. Availability of approved self-contained self-rescue devices; instruction in use and location. The provisions of 30 CFR 75.1714 (relating to availability of approved self-rescue devices; instruction in use and location) are incorporated…
25 Pa. Code Ch. 208 § 208.62 Approved self-contained self-rescue devices
0.2K chars
§ 208.62. Approved self-contained self-rescue devices. The provisions of 30 CFR 75.1714-1 (relating to approved self-rescue devices) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.63 Self-contained self-rescue devices; use and location requirements
0.2K chars
§ 208.63. Self-contained self-rescue devices; use and location requirements. The provisions of 30 CFR 75.1714-2 (relating to self-rescue devices; use and location requirements) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.64 Self-contained self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping
0.3K chars
§ 208.64. Self-contained self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping. The provisions of 30 CFR 75.1714-3 (relating to self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.65 Additional self-contained self-rescue devices
0.2K chars
§ 208.65. Additional self-contained self-rescue devices. The provisions of 30 CFR 75.1714-4 (relating to additional self-contained self-rescuers (SCSRs)) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.66 Map locations
0.2K chars
§ 208.66. Map locations. The provisions of 30 CFR 75.1714-5 (relating to map locations of self-contained self-rescuers (SCSR)) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.67 Emergency tethers
0.1K chars
§ 208.67. Emergency tethers. The provisions of 30 CFR 75.1714-6 (relating to emergency tethers) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.68 Multi-gas detectors
0.1K chars
§ 208.68. Multi-gas detectors. The provisions of 30 CFR 75.1714-7 (relating to multi-gas detectors) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.69 Reporting SCSR inventory, malfunctions and retention
0.2K chars
§ 208.69. Reporting SCSR inventory, malfunctions and retention. The provisions of 30 CFR 75.1714-8 (relating to reporting SCSR inventory and malfunctions; retention of SCSRs) are incorporated by reference.
25 Pa. Code Ch. 208 § 208.70 Automated external defibrillators
2.1K chars
AUTOMATED EXTERNAL DEFIBRILLATORS § 208.70. Automated external defibrillators. (a) Location. A mine operator, in consultation with emergency medical technicians, shall provide for use in an emergency one AED at the following locations: (1) At a location on the surface in close pr…
25 Pa. Code Ch. 208 § 208.71 Maintenance of incombustible content of rock dust
1.0K chars
COMBUSTIBLE MATERIALS AND ROCK DUSTING § 208.71. Maintenance of incombustible content of rock dust. (a) Where rock dust is required to be applied, it shall be distributed upon the top, floor and sides of the underground areas of a coal mine and maintained in quantities so that th…
25 Pa. Code Ch. 208 § 208.81 Scope
0.4K chars
HIGH-VOLTAGE CONTINUOUS MINING MACHINE STANDARDS FOR UNDERGROUND COAL MINES § 208.81. Scope. The provisions of 30 CFR 75.823 (relating to scope) are incorporated by reference. Authority The provisions of this § 208.81 issued under sections 106 and 106.1 of the Bituminous Coal Min…
25 Pa. Code Ch. 208 § 208.82 Electrical protection
0.4K chars
§ 208.82. Electrical protection. The provisions of 30 CFR 75.824 (relating to electrical protection) are incorporated by reference. Authority The provisions of this § 208.82 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act (52 P. S. § § 690-106 and 690-1…
25 Pa. Code Ch. 208 § 208.83 Power centers
0.4K chars
§ 208.83. Power centers. The provisions of 30 CFR 75.825 (relating to power centers) are incorporated by reference. Authority The provisions of this § 208.83 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act (52 P. S. § § 690-106 and 690-106.1). Source Th…
25 Pa. Code Ch. 208 § 208.84 High-voltage trailing cables
0.4K chars
§ 208.84. High-voltage trailing cables. The provisions of 30 CFR 75.826 (relating to high-voltage trailing cables) are incorporated by reference. Authority The provisions of this § 208.84 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act (52 P. S. § § 690…
25 Pa. Code Ch. 208 § 208.85 Guarding of trailing cables
0.4K chars
§ 208.85. Guarding of trailing cables. The provisions of 30 CFR 75.827 (relating to guarding of trailing cables) are incorporated by reference. Authority The provisions of this § 208.85 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act (52 P. S. § § 690-1…
25 Pa. Code Ch. 208 § 208.86 Trailing cable pulling
0.4K chars
§ 208.86. Trailing cable pulling. The provisions of 30 CFR 75.828 (relating to trailing cable pulling) are incorporated by reference. Authority The provisions of this § 208.86 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act (52 P. S. § § 690-106 and 690…
25 Pa. Code Ch. 208 § 208.87 Tramming continuous mining machines in and out of the mine and from section to section
0.5K chars
§ 208.87. Tramming continuous mining machines in and out of the mine and from section to section. The provisions of 30 CFR 75.829 (relating to tramming continuous mining machines in and out of the mine and from section to section) are incorporated by reference. Authority The prov…
25 Pa. Code Ch. 208 § 208.88 Splicing and repair of trailing cables
0.7K chars
§ 208.88. Splicing and repair of trailing cables. (a) Incorporation by reference. The provisions of 30 CFR 75.830(a) (relating to splicing and repair of trailing cables) are incorporated by reference. (b) Splicing limitations. (1) Splicing of the high-voltage trailing cable withi…
25 Pa. Code Ch. 208 § 208.89 Electrical work; troubleshooting and testing
0.4K chars
§ 208.89. Electrical work; troubleshooting and testing. The provisions of 30 CFR 75.831 (relating to electrical work; troubleshooting and testing) are incorporated by reference. Authority The provisions of this § 208.89 issued under sections 106 and 106.1 of the Bituminous Coal M…
25 Pa. Code Ch. 208 § 208.90 Frequency of examinations; recordkeeping
0.4K chars
§ 208.90. Frequency of examinations; recordkeeping. The provisions of 30 CFR 75.832 (relating to frequency of examinations; recordkeeping) are incorporated by reference. Authority The provisions of this § 208.90 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safe…
25 Pa. Code Ch. 208 § 208.91 Handling high-voltage trailing cables
0.4K chars
§ 208.91. Handling high-voltage trailing cables. The provisions of 30 CFR 75.833 (relating to handling high-voltage trailing cables) are incorporated by reference. Authority The provisions of this § 208.91 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act…
25 Pa. Code Ch. 208 § 208.92 Training
0.4K chars
§ 208.92. Training. The provisions of 30 CFR 75.834 (relating to training) are incorporated by reference. Authority The provisions of this § 208.92 issued under sections 106 and 106.1 of the Bituminous Coal Mine Safety Act (52 P. S. § § 690-106 and 690-106.1). Source The provisio…
25 Pa. Code Ch. 208 § 208.93 Installation of electric equipment and conductors; permissibility
0.5K chars
§ 208.93. Installation of electric equipment and conductors; permissibility. The provisions of 30 CFR 75.1002 (relating to installation of electric equipment and conductors; permissibility) are incorporated by reference. Authority The provisions of this § 208.93 issued under sect…