Design standards

Act 132 of 2006, § 5, under RESIDENTIAL VISITABILITY DESIGN TAX CREDIT ACT.

Act 132 of 2006, § 5

Section 5. Design standards.

(a) General standards.--The architectural design of a visitable home shall comply with all of the following requirements:

(1) The path from either a vehicle parking area or a

pedestrian entrance to the lot to the no-step entrance shall

be firm, stable and slip resistant.

(i) The grade of the path shall not exceed the

following acceptable slopes: 1:8 for slope length of five

feet or less with a maximum rise of 7.5 inches; 1:10 for

slope length of 12 feet or less with a maximum rise of

14.4 inches; and 1:12 for slope length of more than 12

feet.

(ii) Notwithstanding subparagraph (i), if the

average slope of the property line along and contiguous

to the public right-of-way exceeds a slope of 1:12, the

slope of the exterior circulation path may be greater, if

necessary, to provide access to the no-step entry, but it

may not exceed the average slope of the property line.

(2) The residence shall provide at least one no-step

entrance approachable by a firm, stable and slip-resistant

path with an acceptable slope. The no-step entrance shall

have a threshold of no greater than three-fourths of an inch.

The no-step entrance to the residence may be located on any

exterior side of the house or an entrance through the

integral garage to the visitable level of the residence.

(3) All no-step entry doors must have a minimum clear

open width of at least 32 inches and be equipped with lever

handle hardware.

(4) Interior circulation paths on the visitable level of

the dwelling must be at least 36 inches in width.

(5) All interior doorways on the visitable level of the

dwelling, excluding closets and doorways to floors below the

visitable level, shall have a minimum clear open width of 32

inches.

(6) Each visitable dwelling shall have a minimum of one

powder room or bathroom on the visitable-level floor. The

powder room shall have a 30-inch by 48-inch minimum clear

floor space contiguous to the water closet and the lavatory.

The clear space under the lavatory may be included in these

measurements, and clear spaces contiguous to the water closet

and lavatory may overlap. Plumbing fixtures and entry-room

doors accessing the visitable powder room must be equipped

with lever-style hardware.

(7) (i) All bathrooms and powder rooms throughout the

residential unit shall have reinforcement of at least two

inches by eight inches of blocking between the studs

placed inside the walls for easy installation of grab

bars if needed. Reinforcement shall be capable of

supporting grab bars that resist shear and bending forces

of 250 pounds or greater. Blocking should be centered at

34 inches from and parallel to the finished floor.

(ii) Notwithstanding subparagraph (i), in renovated

homes only the walls in powder rooms or bathrooms on the

visitable floor and those on floors that have the stud

walls exposed as part of the renovation process need to

comply with this paragraph.

(8) (i) Light switches may not be higher than 48 inches

above the finished floor of the residential unit. If

there are two controls for the same light, only one need

be in compliance with these standards.

(ii) Notwithstanding subparagraph (i), in renovated

homes only the switches on the visitable floor need to

comply with this paragraph unless the electrical

renovations extend beyond the visitable floor.

(b) Modifications.--The design standards contained in this section may not be modified or made mandatory, except as provided by the act of November 10, 1999 (P.L.491, No.45), known as the Pennsylvania Construction Code Act.