100 chapters · 1,959 sections in this title.
SDCL § 34-29A-1 Definition of terms
2.3K chars
Terms as used in this chapter, unless the context otherwise requires, mean: (1) "Boiler," a closed vessel in which water is heated, steam is generated, steam is superheated, or any combination thereof, under pressure or vacuum, for use externally to itself by the direct applicati…
SDCL § 34-29A-10 Replacement of lost or destroyed commission
0.1K chars
If a commission is lost or destroyed, a new commission shall be issued in its place without another examination. Source: SL 1973, ch 229 , § 13.
SDCL § 34-29A-11 Hearing on qualifications of special inspector--Revocation of commission
0.6K chars
If the chief inspector has reason to believe that a special inspector is no longer qualified to hold his commission, the Department of Public Safety shall, upon not less than ten days' written notice to the inspector and his employer, hold a hearing at which such inspector and hi…
SDCL § 34-29A-12 Suspension of special inspector's commission--Grounds--Notice--Appeal
0.8K chars
A special inspector's commission may be suspended by the Department of Public Safety after due investigation and recommendation by the chief inspector, for the incompetence or untrustworthiness of the holder thereof or for willful falsification of any matter or statement containe…
SDCL § 34-29A-13 Reinstatement of suspended commission
0.2K chars
A person whose commission has been suspended shall be entitled to apply, after ninety days from the date of suspension, for reinstatement of such commission. Source: SL 1973, ch 229 , § 12.
SDCL § 34-29A-14 Boilers exempt from application of chapter
0.9K chars
This chapter does not apply to the following boilers: (1) Boilers under federal control; (2) Boilers located on farms if the farm is not regularly open to the general public and the boiler is used solely for agricultural or horticultural purposes; (3) Heating boilers which are lo…
SDCL § 34-29A-14.1 Rules and regulations for inspection of historic power boilers
0.2K chars
The Department of Public Safety shall promulgate rules, pursuant to chapter 1-26 , to provide for the inspection of those historic power boilers otherwise exempt from the provisions of this chapter by §
SDCL § 34-29A-14.2 Inspectors of historic power boilers
0.1K chars
The Department of Public Safety may appoint inspectors to assist in the inspection of historic power boilers as provided by §
SDCL § 34-29A-15 Repealed by SL 1982, ch 18 , § 44
0.1K chars
34-29A-16 Program of boiler inspection established by department--Rules. 34-29A-17
SDCL § 34-29A-16 Program of boiler inspection established by department--Rules
1.1K chars
The Department of Public Safety shall establish a program of boiler inspection for safety and uniformity in the use of boilers. The secretary of public safety may adopt reasonable and necessary rules to protect the health or safety of persons from boiler explosions and like emerg…
SDCL § 34-29A-17 Temporary and executed
1.0K chars
34-29A-18 34-29A-18 to 34-29A-21. Repealed by SL 1982, ch 18 , §§ 46 to 49. 34-29A-22 Maximum allowable pressure of boilers--Computation. 34-29A-23 Reuse of existing boilers. 34-29A-24 New boilers to conform to rules--Special installation and operation certificate. 34-29A-25 Cert…
SDCL § 34-29A-2 Inspectors within department
0.3K chars
There shall be within the Department of Public Safety a chief boiler inspector (referred to hereinafter as the "chief inspector") who shall be selected as provided in § 34-29A-3 and such deputy inspectors as may be required, selected as provided in §
SDCL § 34-29A-22 Maximum allowable pressure of boilers--Computation
0.4K chars
The maximum allowable pressure of a boiler carrying the ASME code symbol shall be determined by the applicable sections of the code under which it was constructed and stamped. The maximum allowable pressure of a boiler which does not carry the ASME code symbol shall be computed b…
SDCL § 34-29A-23 Reuse of existing boilers
0.4K chars
This chapter shall not be construed as in any way preventing the use, sale, or reinstallation of a boiler referred to in § 34-29A-22 provided it has been made to conform to the rules and regulations of the Department of Public Safety governing existing installations and provided,…
SDCL § 34-29A-24 New boilers to conform to rules--Special installation and operation certificate
0.6K chars
No boiler which does not conform to the rules and regulations of the Department of Public Safety governing new construction and installation may be installed and operated in this state after June 30, 1974, unless the boiler is of special design or construction, and is not inconsi…
SDCL § 34-29A-25 Certificate required to operate boiler--Unauthorized operation as misdemeanor--Each day as separate offense
0.6K chars
No person, firm, partnership, limited liability company, or corporation may operate in this state a boiler without a valid operation certificate. The operation of a boiler without the operation certificate, or at a pressure exceeding that specified in the operation certificate, b…
SDCL § 34-29A-26 Inspections required for operating boilers--Frequency of inspection
1.4K chars
Each boiler used or proposed to be used within this state, except boilers exempt under § 34-29A-14 , shall be thoroughly inspected as to their construction, installation and condition as follows: (1) Power boilers and high pressure, high temperature water boilers shall receive a …
SDCL § 34-29A-27 Inspection of new boilers during construction--Construction outside state for use within state
0.5K chars
All boilers, other than cast iron sectional boilers, installed in this state after June 30, 1974, shall be inspected during construction as required by the applicable rules and regulations of the Department of Public Safety by an inspector authorized to inspect boilers in this st…
SDCL § 34-29A-28 Persons authorized to make inspections
0.2K chars
The inspections required in this chapter shall be made by the chief inspector, by a deputy inspector, or by a special inspector provided for in this chapter. Source: SL 1973, ch 229 , § 14.
SDCL § 34-29A-29 State inspectors' access to premises for inspection during construction
0.5K chars
The Department of Public Safety, the chief inspector, or any deputy inspector shall have free access, during reasonable hours, to any premises in the state where a boiler is being constructed for use in, or is being installed in, this state for the purpose of ascertaining whether…
SDCL § 34-29A-3 Qualifications and appointment of chief inspector
0.7K chars
At any time that the office of the chief inspector may become vacant, the secretary of public safety shall appoint a person who shall have had at the time of such appointment not less than five years' experience in the construction, installation, inspection, operation, maintenanc…
SDCL § 34-29A-32 Variations in inspection requirements for operating equipment
0.3K chars
Based upon documentation of actual service conditions by the owner or user of the operating equipment, the chief inspector in his discretion, may permit variations in the inspection requirements for operating equipment. Source: SL 1973, ch 229 , § 14.
SDCL § 34-29A-33 Hydrostatic tests of operating equipment
0.2K chars
If, at the discretion of the inspector, a hydrostatic test of operating equipment shall be deemed necessary, it shall be made by the owner or user of the boiler. Source: SL 1973, ch 229 , § 14.
SDCL § 34-29A-34 Secretary or designee to issue, suspend or revoke certificates
0.3K chars
The secretary of public safety, or his designee, shall issue, or suspend or revoke for cause, operation certificates as provided for in §§ 34-29A-39 to 34-29A-43 , inclusive. Source: SL 1973, ch 229 , § 8 (4); SL 1982, ch 18 , § 57; SL 2003, ch 272 , §§ 20, 121. 34-29A-35. Repeal…
SDCL § 34-29A-35 Repealed by SL 1978, ch 257 , § 2
1.2K chars
34-29A-35.1 Inspection fees. 34-29A-36 Additional fee for reinspection trip. 34-29A-37 Daily rates charged for other inspections. 34-29A-38 Inspection reports by special inspectors. 34-29A-39 Certificate issued on special inspector's report. 34-29A-40 Posting of certificates. 34-…
SDCL § 34-29A-35.1 Inspection fees
1.7K chars
The owner or user of a boiler required by this chapter to be inspected by the chief inspector, or a deputy inspector, shall pay directly to the State of South Dakota through the Office of the State Fire Marshal, upon completion of the inspection, fees in accordance with the follo…
SDCL § 34-29A-36 Additional fee for reinspection trip
0.4K chars
If it is necessary for the chief inspector or his deputy inspector to make a reinspection trip to witness the application of a hydrostatic test due to deficiencies noted in a previous inspection, an additional fee based on the scale of fees applicable to a certificate inspection …
SDCL § 34-29A-37 Daily rates charged for other inspections
0.5K chars
All other inspections, including shop inspections, special inspections, and inspections of secondhand or used boilers made by the chief or deputy inspector shall be charged for at the rate of not less than ninety dollars for one - half day of four hours, and one hundred fifty dol…
SDCL § 34-29A-38 Inspection reports by special inspectors
0.6K chars
Each company employing special inspectors meeting the requirements of § 34-29A-6 shall, within thirty days following each certificate inspection made by the inspectors, file a report of the inspection with the Office of the State Fire Marshal upon appropriate forms as promulgated…
SDCL § 34-29A-39 Certificate issued on special inspector's report
0.5K chars
If the report filed pursuant to § 34-29A-38 shows that a boiler is found to comply with the rules and regulations of the Department of Public Safety, the chief inspector or his duly authorized representative, shall issue to such owner or user an operation certificate bearing the …
SDCL § 34-29A-4 Qualifications and employment of deputy inspectors
0.4K chars
The Department of Public Safety may employ deputy inspectors who shall have had at the time of appointment not less than three years' experience in the construction, installation, inspection, operation, maintenance, or repair of boilers as a mechanical engineer, steam operating e…
SDCL § 34-29A-40 Posting of certificates
0.3K chars
Certificates shall be posted under glass in the room containing the boiler inspected. If the boiler is not located within the building, the certificate shall be posted in a location convenient to the boiler inspected, or in any place where it will be accessible to interested part…
SDCL § 34-29A-41 Certificate issued on special inspector's report invalid after termination of insurance
0.3K chars
No operation certificate issued for an insured boiler based upon a report of a special inspector is valid after the boiler for which it was issued ceases to be insured by a company duly authorized by this state to provide such insurance. Source: SL 1973, ch 229 , § 15; SL 1982, c…
SDCL § 34-29A-42 Duration of certificates issued on special inspector's reports
0.7K chars
An operation certificate issued pursuant to § 34-29A-39 is valid for not more than fourteen months from its date in the case of power boilers and high pressure, high temperature water boilers and twenty - six months in the case of heating boilers and hot water supply boilers. In …
SDCL § 34-29A-43 Suspension of certificate for unsafe or noncomplying boiler--Duration of suspension
0.7K chars
The Department of Public Safety or its authorized representative may at any time suspend an operation certificate when, in its opinion, the boiler for which it was issued, cannot be operated without menace to the public safety, or when the boiler is found not to comply with the r…
SDCL § 34-29A-46 Record of boilers and inspections
0.3K chars
The secretary of public safety, or his designee, shall keep a complete record of the type, dimensions, maximum allowable pressure, age, location, and date of the last recorded inspection of all boilers to which this chapter applies. Source: SL 1973, ch 229 , § 8 (2); SL 1982, ch …
SDCL § 34-29A-46.1 Operating boilers--Notification requirements
0.6K chars
The owner or installing contractor of a boiler operating in the state subject to this chapter shall notify the Office of the State Fire Marshal of its location and operating pressure. The notification for new boilers shall be given prior to the commencement of operation, and for …
SDCL § 34-29A-47 Enforcement actions
0.3K chars
The secretary of public safety, or his designee, shall take action necessary for the enforcement of the laws of the state governing the use of boilers to which this chapter applies and of the rules and regulations of the Department of Public Safety. Source: SL 1973, ch 229 , § 8 …
SDCL § 34-29A-48 Appeals from inspectors--Order approving or disapproving inspector's act
0.5K chars
Any person aggrieved by an order or an act of the chief inspector or his deputies, under this chapter may, within fifteen days' notice thereof, appeal from such order or act to the secretary of public safety who shall, within thirty days thereafter, issue an appropriate order eit…
SDCL § 34-29A-49 Judicial review of order--Summary hearing
0.3K chars
Within thirty days after any order or act of the secretary of public safety, any person aggrieved thereby may file a petition in the circuit court for a review thereof. The court shall summarily hear the petition and may make any appropriate order or decree. Source: SL 1973, ch 2…
SDCL § 34-29A-5 Repealed by SL 1982, ch 18 , § 37
1.0K chars
34-29A-6 Commissions issued to special inspectors employed by insurance companies--Examination or previous certification required. 34-29A-7 Insured boilers inspected by special inspectors--Exemption from state fees except boiler annual operation certificate. 34-29A-8 Special insp…
SDCL § 34-29A-50 Prosecution of violators
0.2K chars
The secretary of public safety, or his designee, shall cause the prosecution of all violators of the provisions of this chapter. Source: SL 1973, ch 229 , § 8 (5); SL 1982, ch 18 , § 70; SL 2003, ch 272 , §§ 20, 121.
SDCL § 34-29A-51 Deposit of fees in boiler inspection fund
0.3K chars
The secretary of public safety, or his designee, shall deposit all fees received pursuant to §§ 34-29A-35.1 to 34-29A-37 , inclusive, to the treasurer of the state for deposit into the boiler inspection fund. Source: SL 1973, ch 229 , § 17; SL 1982, ch 18 , § 71; SL 1989, ch 48 ,…
SDCL § 34-29A-52 Expenditure of funds--Expenses included
0.1K chars
The chief inspector and his deputies shall be reimbursed for the travel expense incident to the maintenance of his office pursuant to §
SDCL § 34-29A-53 Municipal ordinances not to be less restrictive--Conflicting ordinances void
0.5K chars
No municipality or other governmental subdivision may make any laws, ordinances, or resolutions providing for the construction, installation, inspection, operation, maintenance, and repair of boilers within the limits of such municipality or governmental subdivision which are les…
SDCL § 34-29A-6 Commissions issued to special inspectors employed by insurance companies--Examination or previous certification required
1.2K chars
In addition to the deputy boiler inspectors authorized by § 34-29A-4 , the Department of Public Safety shall, upon the request of any company licensed to insure and insuring in this state boilers, issue to any inspectors of said company commissions as special inspectors, provided…
SDCL § 34-29A-7 Insured boilers inspected by special inspectors--Exemption from state fees except boiler annual operation certificate
0.5K chars
Special inspectors issued commissions pursuant to § 34-29A-6 shall inspect all boilers insured by their respective companies and, if so inspected, the owners and users of the boilers are exempt from the payment to the state of the inspection fees provided for in §§ 34-29A-35.1 to…
SDCL § 34-29A-8 Special inspectors not paid by state--Commission conditioned on continuing employment
0.4K chars
Special inspectors issued commissions pursuant to § 34-29A-6 shall receive no salary from, nor shall any of their expenses be paid by, the state, and the continuance of a special inspector's commission shall be conditioned upon his continuing in the employ of the boiler insurance…
SDCL § 34-29A-8.1 Inspection--Liability
0.6K chars
Any boiler inspection required by § 34-29A-7 that is performed by a special inspector authorized pursuant to § 34-29A-6 and conducted incidental to the issuance or renewal of boiler and machinery insurance, may not subject an insurer, its agents, or its employees to any liability…
SDCL § 34-29A-9 Examinations for inspectors--Scope--Second examination on appeal--Records available to applicant and employer
0.8K chars
Examination for chief, deputy, or special inspectors shall be in writing and shall be under the direction of the Department of Public Safety. Such examination shall be confined to questions the answers to which will aid in determining the fitness and competency of the applicant f…