When a coal-fired utility unit becomes an affected unit under the law, it must follow limits on nitrogen oxides (NOx) emissions. The Administrator must set yearly NOx limits for certain boiler types within eighteen months after November 15, 1990. For tangentially fired boilers the limit cannot be more than 0.45 lb/mmBtu, and for dry bottom wall-fired boilers (except those using cell burners) it cannot be more than 0.50 lb/mmBtu. After January 1, 1995, affected units of those types may not emit more than the set rates. By January 1, 1997, the Administrator must also set annual NOx limits for wet bottom wall-fired boilers, cyclones, cell-burner units, and all other boiler types based on the best retrofit technology that is reasonably achievable. The permitting authority can allow a less strict limit if an owner proves the unit cannot meet the standard using the required technology. To do that, the owner must install the control equipment, operate it for about fifteen months and give the operating data, and state a realistic annual rate the unit can meet. Owners may average emissions across two or more units if the averaged rate is no higher than the weighted rate they would have had under the standard limits. The Administrator may extend some compliance deadlines by 15 months if the needed technology is not available, and must decide petitions about such extensions within 3 months.