R11-1-2013 Reserved
0.0K chars
R11-1-2014 Reserved
0.0K chars
R11-1-2015 Tanks labeled
0.1K chars
All tanks must be labeled as to contents. Historical Note Former Rule 20:15.
R11-1-2016 Tanks provided with means of measuring
0.1K chars
All tanks shall be provided with a safe means of measuring content level. Historical Note Former Rule 20:16.
R11-1-2017 Tanks labeled as to contents
0.1K chars
All reagent containers must be labeled as to contents and stored in designated areas. Historical Note Former Rule 20:17.
R11-1-2018 Liquid storage tanks, suitable means of disposal
0.3K chars
All liquid storage tanks shall be supplied with suitable means of containment or disposal to provide safe disposal of contents in event of tank failure. Liquid storage tanks must also be equipped with overfill piping to contain overflow to a suitable and safe disposal area. Histo…
R11-1-2019 Storage tanks vented
0.1K chars
All storage tanks must be vented except those under pressure. Historical Note Former Rule 20:19.
R11-1-2020 Reagent containers stored
0.2K chars
Reagent containers shall be stored so as to protect the contents from the effects of weather if such exposure would create a hazardous situation. Historical Note Former Rule 20:20.
R11-1-2021 Oxidizing agents stored
0.2K chars
Oxidizing agents shall not be stored adjacent to reducing agents or flammable material where container failure could allow combining of materials. Historical Note Former Rule 20:21.
R11-1-2022 Warning signs at reagent storage areas
0.2K chars
Suitable warning signs shall be posted at all reagent storage areas limiting entry and smoking, where a hazard exists. Historical Note Former Rule 20:22.
R11-1-2023 Reagent tanks emitting toxic vapor
0.2K chars
Reagent tanks capable of emitting toxic vapor shall be either located outside the mill building or positively vented to the outside. Historical Note Former Rule 20:23.
R11-1-2024 Reagent stocks rotated
0.1K chars
Reagent stocks should be rotated on a first-in, first-out basis. Historical Note Former Rule 20:24.
R11-1-2025 Stacking reagent containers
0.1K chars
Stacking of reagent containers shall not present a hazard. Historical Note Former Rule 20:25.
R11-1-2026 Disposal obsolete reagents
0.1K chars
Disposal of obsolete reagents should be accomplished according to safe procedure. Historical Note Former Rule 20:26.
R11-1-2027 Broken containers or spilled reagents
0.1K chars
Broken containers or spilled reagents must be cleaned up immediately. Historical Note Former Rule 20:27.
R11-1-2028 Reagent storage facilities well drained
0.2K chars
Reagent storage facilities shall be well drained. Storage facilities should be constructed of fire-resistant material if reagents stored therein are flammable or corrosive to wood. Historical Note Former Rule 20:28.
R11-1-2029 Heat applied to storage tanks
0.1K chars
Heat shall not be applied to storage tanks except in compliance with recognized Trade Association Handling Code. Historical Note Former Rule 20:29.
R11-1-2030 Reserved
0.0K chars
R11-1-2031 Hazardous reagents mixed
0.1K chars
Hazardous reagents shall be mixed in areas that minimize personnel exposure. Historical Note Former Rule 20:31.
R11-1-2032 Personnel mixing reagents
0.1K chars
All personnel mixing reagents must be trained in the mixing procedure. Historical Note Former Rule 20:32.
R11-1-2033 Phosphorous pentasulfide
0.5K chars
Phosphorous pentasulfide shall be added slowly to the sodium hydroxide solution from a container large enough to hold just the amount needed for one bath. This conveyor shall be constructed of spark-resistant materials, driven by an explosion-proof motor, thermostatically control…
R11-1-2034 Men designated for hazardous reagent mixing certified
0.2K chars
Men designated for hazardous reagent mixing must be certified by the mill superintendent and a copy of such names filed in the office of the mill superintendent and available to the Arizona Mine Inspector. Historical Note Former Rule 20:34.
R11-1-2035 Mixing tanks and holding tanks labeled
0.1K chars
All mixing tanks and holding tanks shall be labeled as to contents. Historical Note Former Rule 20:35.
R11-1-2036 Mixing tanks used for different reagents
0.2K chars
If a mixing tank is used for different reagents, and if a hazard exists, the tank and distribution lines should be flushed after mixing each reagent. Historical Note Former Rule 20:36.
R11-1-2037 Reagent mixes with exothermic reaction
0.2K chars
Reagent mixes with exothermic reaction shall be subject to positive temperature control if such reaction can create a hazard. Historical Note Former Rule 20:37.
R11-1-2038 Adequate ventilation in mixing area
0.1K chars
Hazardous reagent mixing areas must have adequate ventilation. Historical Note Former Rule 20:38.
R11-1-2039 Suitable warning signs at mixing area
0.2K chars
Suitable warning signs shall be posted at all reagent mixing areas, limiting entry and smoking where a hazard exists. Historical Note Former Rule 20:39.
R11-1-2040 Hydrogen storage
0.4K chars
Hydrogen shall be stored in an open area which shall be roofed to prevent direct sunlight from heating the containers. The area shall be posted with “No Smoking” or “Open Flame” signs. ARTICLE 21. ASSAY AND METALLURGICAL LABORATORIES The rules in this Article are adopted in accor…
R11-1-2101 Mixing or heating of chemicals producing noxious fumes or gases
0.2K chars
All mixing or heating of chemicals that may produce noxious fumes or gases must be performed under a hood or performed in adequately ventilated enclosures. Historical Note Former Rule 21:01.
R11-1-2102 Hoods ventilated
0.1K chars
Hoods must be positively ventilated to the outside. Historical Note Former Rule 21:02.
R11-1-2103 Velocity of air moving through the hood
0.1K chars
There shall be sufficient velocity of air moving through the hood to remove all fumes or gas produced in the hood. Historical Note Former Rule 21:03.
R11-1-2104 When hood fails to exhaust properly
0.2K chars
When a hood fails to exhaust properly, it will be promptly reported to maintenance and repaired before being used again. Historical Note Former Rule 21:04.
R11-1-2105 No unplanned recirculation of exhaust air
0.1K chars
A means shall be provided to assure that no unplanned recirculation of exhaust air occurs. Historical Note Former Rule 21:05.
R11-1-2106 Involving the use of perchloric acid
0.4K chars
Hoods and ducts that are to be used in the digestion and/or evaporation, involving the use of perchloric acid must be made of chemically inert, non-combustible material and so constructed and designed that they can be thoroughly washed with water. The exhaust system shall dischar…
R11-1-211 Smoking, matches, open flames prohibited in specified areas
0.5K chars
Smoking, matches, open flames, spark-producing devices and carrying of firearms or ammunition shall be prohibited in or within 50 feet of the following areas: 1. Explosive and blasting supply magazines. 2. Blasting agent and oxidizer storage sites. 3. Blasting agent mixing plants…
R11-1-212 Transporting explosives
0.2K chars
No persons shall drive, load, or unload a vehicle transporting explosives, blasting agents, or oxidizers in a careless or reckless manner. Historical Note Former Rule 2:12.
R11-1-213 Precautions governing use, transportation and handling
0.2K chars
The precautions, rules and regulations governing the use, transportation and handling of explosives shall apply to all blasting agents except as otherwise expressly provided herein. Historical Note Former Rule 2:13.
R11-1-214 Repair of vehicles containing explosives
0.1K chars
Vehicles containing explosives or detonators shall not be taken to a repair garage or shop for any purpose. Historical Note Former Rule 2:14.
R11-1-215 Unattended vehicles containing detonators or other explosives
0.2K chars
Vehicles containing detonators or explosives, other than blasting agents, shall not be left unattended except in blasting areas where loading or charging is in progress. Historical Note Former Rule 2:15.
R11-1-216 Notification to men responsible for operating hoists and cagers
0.2K chars
Men responsible for operating the hoist and cagers shall be notified whenever explosives or detonators are being transported in a shaft conveyance. Historical Note Former Rule 2:16.
R11-1-217 Hoisting stopped
0.1K chars
Hoisting in adjacent shaft compartments shall be stopped when explosives or detonators are being handled. Historical Note Former Rule 2:17.
R11-1-218 Reserved
0.0K chars
R11-1-219 Reserved
0.0K chars
R11-1-220 Reserved
0.0K chars
R11-1-2201 Reserved
0.0K chars
R11-1-2202 Cyanide Safety Training
1.1K chars
A. Supervisors working in an area where cyanide is used or stored shall successfully complete a cyanide safety course conducted by the State Mine Inspector prior to starting a cyanide leaching operations. B. Employees working in an area where cyanide is used or stored shall be in…
R11-1-2203 Posting of Emergency Procedures
0.3K chars
Cyanide first-aid emergency procedures shall be posted and visible at the operations main office and at each first-aid station and in all areas where cyanide is handled. Historical Note Adopted effective August 2, 1985 (Supp. 85-4). Amended effective July 6, 1993 (Supp. 93-3).
R11-1-2204 Emergency Provisions, Cyanide Antidote Kits
1.5K chars
A. Approved cyanide antidote kits for treatment of cyanide poisoning shall be made available at workplaces where cyanide is used, stored, or handled or where there is a potential for exposure to hydrogen cyanide gas or dry or solution cyanide contamination. B. An approved cyanide…
R11-1-2205 Conditions for Employee Working Alone
0.4K chars
No employee shall be assigned or permitted to work alone in any area where hazardous conditions exist or may exist that would endanger the worker’s safety unless the worker can communicate with others in the immediate vicinity or can be visually observed at all times. Historical …
R11-1-2206 Attendance
0.2K chars
No cyanide leaching operation shall be left unattended while cyanide is present in dry or solution form. Historical Note Adopted effective August 2, 1985 (Supp. 85-4). Amended effective July 6, 1993 (Supp. 93-3).