470 sections in this chapter.
R20-5-325 Expired
0.2K chars
Historical Note Adopted effective September 9, 1998 (Supp. 98-3). Section expired under A.R.S. § 41-1056(J) at 23 A.A.R. 297, effective January 3, 2017 (Supp. 17-1).
R20-5-326 Expired
0.2K chars
Historical Note Adopted effective September 9, 1998 (Supp. 98-3). Section expired under A.R.S. § 41-1056(J) at 23 A.A.R. 297, effective January 3, 2017 (Supp. 17-1).
R20-5-327 Expired
0.2K chars
Historical Note Adopted effective September 9, 1998 (Supp. 98-3). Section expired under A.R.S. § 41-1056(J) at 23 A.A.R. 297, effective January 3, 2017 (Supp. 17-1).
R20-5-328 Expired
0.2K chars
Historical Note Adopted effective September 9, 1998 (Supp. 98-3). Section expired under A.R.S. § 41-1056(J) at 23 A.A.R. 297, effective January 3, 2017 (Supp. 17-1).
R20-5-329 Expired
0.2K chars
Historical Note Adopted effective September 9, 1998 (Supp. 98-3). Section expired under A.R.S. § 41-1056(J) at 23 A.A.R. 297, effective January 3, 2017 (Supp. 17-1). ARTICLE 4. ARIZONA BOILERS AND LINED HOT WATER HEATERS
R20-5-401 Applicability
1.4K chars
This Article applies to all Boilers, Lined Hot Water Heaters, and Pressure Vessels operated in Arizona, except the following: 1. Boilers, Lined Hot Water Heaters, and Pressure Vessels regulated by the United States Government; 2. Boilers, Lined Hot Water Heaters, and Pressure Ves…
R20-5-402 Definitions
6.9K chars
In addition to the definitions provided in A.R.S. § 23-471, the following definitions apply to this Article: “Act” means A.R.S. Title 23, Chapter 2, Article 11. “Alteration” means any change in the item described on the original manufacturer’s data report which affects the pressu…
R20-5-403 Repealed
0.5K chars
Historical Note Former Rules B-3.1 through B-3.3. Former Section R4-13-403 repealed, new Section R4-13-403 adopted effective April 12, 1978 (Supp. 79-2). Section R4-13-403 repealed, new Section adopted effective April 9, 1992 (Supp. 92-2). R20-5-403 recodified from R4-13-403 (Sup…
R20-5-404 Standards for Boilers, Lined Hot Water Heaters and Pressure Vessels
10.6K chars
A. The following apply to this Article: 1. An Owner, Operator, or User, of a Boiler, Lined Hot Water Heater or Pressure Vessel installed, repaired, replaced, or reinstalled in Arizona, six months after the effective date of this Article shall comply with the 2019 ASME Boiler and …
R20-5-405 Repealed
0.4K chars
Historical Note Former Section R4-13-405 repealed effective April 12, 1979 (Supp. 79-2). New Section R4-13-405 adopted effective June 13, 1980 (Supp. 80-3). Section R4-13-405 repealed, new Section adopted effective April 9, 1992 (Supp. 92-2). R20-5-405 recodified from R4-13-405 (…
R20-5-406 Repairs and Alterations
4.4K chars
A. If Repairs or Alterations may affect the working pressure or safety of a Boiler, Lined Hot Water Heater, or Pressure Vessel, an Owner, Operator, or User shall consult with an Authorized Inspector before having the Repairs or Alterations made. The Authorized Inspector shall pro…
R20-5-407 Inspection of Boilers, Lined Hot Water Heaters, Direct Fired Jacketed Steam Kettles and Issuance of Inspection Certificates
5.4K chars
A. An Authorized Inspector shall comply with the guidelines set forth in The National Board Inspection Code, ANSI/NB-23-2019 Edition, incorporated by reference. This incorporation does not include any later amendments or editions of the incorporated material. A copy of this refer…
R20-5-408 Frequency of Inspection
3.8K chars
A. An Owner, Operator, or User, of an existing Power Boiler or High Temperature Water Boiler shall ensure that an Authorized Inspector performs a Certificate Inspection and/or an External Inspection prior to operating the Power Boiler or High Temperature Water Boiler. A Certifica…
R20-5-409 Notification and Preparation for Inspection
1.6K chars
A. An Authorized Inspector shall perform a Certificate Inspection at a time mutually agreeable to the Authorized Inspector and the Owner, Operator, or User. B. Before an Authorized Inspector performs an Internal Inspection of a Boiler, an Owner, Operator, or User shall: 1. Cool t…
R20-5-410 Report of Accident
1.0K chars
An Owner, Operator, or User shall notify the Division within 24 hours of an explosion, severe overheating, or personal injury involving a Boiler, Lined Hot Water Heater, or Direct Fired Jacketed Steam Kettle. A person shall not remove or disturb the involved Boiler, Lined Hot Wat…
R20-5-411 Hydrostatic Tests
0.6K chars
The Owner, Operator, or User of a Boiler shall perform a hydrostatic or pneumatic pressure test in accordance with the code incorporated by reference in R20-5-404(A) and R20-5-406(B). Historical Note Repealed effective April 12, 1979 (Supp. 79-2). New Section adopted effective Ap…
R20-5-412 Automatic Low-water Fuel Cutoff Devices or Combined Water Feeding and Fuel Cutoff Devices
1.1K chars
A. An Owner, Operator, or User shall ensure that low-water fuel cutoff devices or combined water feeding and fuel cutoff devices do not interfere with an Operator’s or Authorized Inspector’s ability to safely clean, repair, or inspect a Boiler, Lined Hot Water Heater, or Pressure…
R20-5-413 Safety and Safety Relief Valves
2.9K chars
A. A valve shall not be placed between a Safety Valve, Relief Valve, or a Safety Relief Valve and the Boiler, Lined Hot Water Heater, or Pressure Vessel, or between a Safety Valve, Relief Valve, or a Safety Relief Valve and the discharge pipe attached to the Boiler, Lined Hot Wat…
R20-5-414 Repealed
0.3K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). New Section adopted effective April 9, 1992 (Supp. 92-2). R20-5-414 recodified from R4-13-414 (Supp. 95-1). Repealed by final rulemaking at 15 A.A.R. 1496, effective August 18, 2009 (Supp. 09-3).
R20-5-415 Boiler Blowdown, Blowoff Equipment and Drains
2.8K chars
A. Except as provided in this Section, an Owner, Operator, or User of blowdown and blowoff equipment shall comply with the National Board of Boiler and Pressure Vessel Inspectors, A Guide for Blowoff Vessels, NB-27, Revision 1 (1/13), 2012 Edition, incorporated by reference. This…
R20-5-416 Maximum Allowable Working Pressure
1.0K chars
A. The ASME Code under which a Boiler, Lined Hot Water Heater, or Pressure Vessel was constructed and stamped shall determine the MAWP. B. If components in the Boiler, or hot water system such as valves, pumps, expansion tanks, storage tanks or piping have a lesser working pressu…
R20-5-417 Maintenance and Operation of Boilers, Lined Hot Water Heaters and Direct Fired Jacketed Steam Kettles
3.3K chars
A. An Owner, Operator, or User of a lined Boiler, Lined Hot Water Heater, or Direct Fired Jacketed Steam Kettle constructed under the ASME Code, Sections I, IV or VIII Division 1, incorporated by reference in R20-5-404(A) shall comply with the manufacturer’s maintenance and opera…
R20-5-418 Non-standard Boilers
0.6K chars
An Owner, Operator, or User shall remove from service a Boiler, Lined Hot Water Heater, or Pressure Vessel that does not bear an ASME stamp unless a variance is requested under R20-5-429. Historical Note Repealed effective April 12, 1979 (Supp. 79-2). New Section adopted effectiv…
R20-5-419 Request to Reinstall Boiler or Lined Hot Water Heater
1.2K chars
A. The Division shall grant or deny approval to reinstall a Boiler or Lined Hot Water Heater within three business days after an Owner, Operator, or User requests approval. The order of the Division granting or denying approval shall be in writing. B. The Division shall grant app…
R20-5-420 Special Inspector Certificate under A.R.S. § 23-485
5.0K chars
A. The Division shall administratively review an Applicant’s application for a Special Inspector Certificate under A.R.S. § 23-485 within seven days of receipt of the application to determine if the application is complete. If the application is incomplete, the Division shall not…
R20-5-421 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-421 recodified from R4-13-421 (Supp. 95-1).
R20-5-422 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-422 recodified from R4-13-422 (Supp. 95-1).
R20-5-423 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-423 recodified from R4-13-423 (Supp. 95-1).
R20-5-424 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-424 recodified from R4-13-424 (Supp. 95-1).
R20-5-425 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-425 recodified from R4-13-425 (Supp. 95-1).
R20-5-426 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-426 recodified from R4-13-426 (Supp. 95-1).
R20-5-427 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-427 recodified from R4-13-427 (Supp. 95-1).
R20-5-428 Repealed
0.1K chars
Historical Note Repealed effective April 12, 1979 (Supp. 79-2). R20-5-428 recodified from R4-13-428 (Supp. 95-1).
R20-5-429 Variance
2.2K chars
A. Any Owner, Operator, or User may apply to the Director for a variance from the requirements of this Article, upon demonstrating the construction, installation, and operation of the Boiler, Lined Hot Water Heater, or Pressure Vessel will maintain the same level of safety as pre…
R20-5-430 Forced Circulation Lined Hot Water Heaters
1.6K chars
A. All water tube or coil-type Lined Hot Water Heaters that require forced circulation to prevent overheating and failure of the tubes or coils shall have a safety control, to prevent burner operation at a flow rate inadequate to protect the Lined Hot Water Heater unit against ov…
R20-5-431 Code Cases
0.5K chars
Code cases approved for use by ASME are allowed to be used in the design, fabrication and testing of Boilers, Lined Hot Water Heaters, and Pressure Vessels provided approval from the boiler chief is obtained prior to use. Historical Note New Section made by final rulemaking at 15…
R20-5-432 Historical Boilers
0.8K chars
Historical boilers shall require an initial Certificate Inspection by an Authorized Inspector in accordance with The National Board Inspection Code, followed by a Certificate Inspection every three years thereafter if stored inside a shelter, or annually if stored outdoors. The i…
R20-5-501 Repealed
0.2K chars
Historical Note Former Rule E-1. Amended effective November 9, 1979 (Supp. 79-6). R20-5-501 recodified from R4-13-501 (Supp. 95-1). Section repealed by final rulemaking at 9 A.A.R. 381, effective March 15, 2003 (Supp. 03-1).
R20-5-502 Definitions
2.4K chars
In addition to the definitions provided in A.R.S. § 23-491, the following definitions apply to this Article: “Alteration” or “altered” means work performed to any conveyance that is not routine maintenance or repair. “ASME” means American Society of Mechanical Engineers. “ANSI” m…
R20-5-503 Repealed
0.2K chars
Historical Note Former Rule E-3. R20-5-503 recodified from R4-13-503 (Supp. 95-1). Section repealed by final rulemaking at 9 A.A.R. 381, effective March 15, 2003 (Supp. 03-1).
R20-5-504 Safety Standard for Platform Lifts and Stairway Chairlifts
1.9K chars
A. Every owner or operator of a platform lift or stairway chairlift installed, repaired, or altered on or after January 1, 2023, shall comply with ASME A18.1-2020 (Safety Standard for Platform Lifts and Stairway Chairlifts), with amendments as of November 29, 2020, which is incor…
R20-5-505 Certificate of Inspection
0.8K chars
The owner or operator of a conveyance shall maintain the Commission’s certificate at the same location as the conveyance or related equipment and make the certificate available for inspection and copying upon request. The State Serial Number or certificate shall be posted or disp…
R20-5-506 Recordkeeping
1.1K chars
A. The Elevator Safety Section shall assign a State Serial Number to every conveyance for recordkeeping purposes. The State Serial Number shall be on a tag that is affixed to the controller or mainline disconnect of the conveyance. B. The owner or operator of a conveyance shall n…
R20-5-507 Safety Code for Elevators, Escalators, Dumbwaiters, Moving Walks, Material Lifts, Special Purpose Personnel Elevators, and Dumbwaiters with Automatic Transfer Devices
4.2K chars
A. Every owner or operator of an elevator, escalator, dumbwaiter, moving walk, material lift, special purpose personnel elevator, or dumbwaiter with automatic transfer device installed, repaired, or altered on or after January 1, 2023, shall comply with the ASME A17.1-2019 (Safet…
R20-5-508 Safety Standard for Manlifts
1.7K chars
A. Every owner or operator of a manlift installed, repaired, or altered on or after January 1, 2023, shall comply with ASME A90.1-2015 (Safety Standard for Belt Manlifts), which is incorporated by reference. For purposes of a repair or alteration, compliance with the specified st…
R20-5-509 Safety Requirements for Personnel Hoists and Employee Elevators for Construction and Demolition Operations
2.1K chars
A. Every owner or operator of a personnel hoist or employee elevator for construction and demolition operation installed, repaired, or altered on or after January 1, 2023, shall comply with ANSI A10.4-2016 (Safety Requirements for Personnel Hoists and Employee Elevators for Const…
R20-5-510 Safety Requirements for Material Hoists
1.8K chars
A. Every owner or operator of a material hoist installed, repaired, or altered on or after January 1, 2023, shall comply with ANSI A10.5-2020 (Safety Requirements for Material Hoists), which is incorporated by reference. For purposes of a repair or alteration, compliance with the…
R20-5-511 Repealed
0.4K chars
Historical Note Adopted effective March 30, 1981 (Supp. 81-2). R20-5-511 recodified from R4-13-511 (Supp. 95-1). Amended by final rulemaking at 9 A.A.R. 381, effective March 15, 2003 (Supp. 03-1). Amended by final rulemaking at 15 A.A.R. 872, effective May 5, 2009 (Supp. 09-2). R…
R20-5-512 Expired
0.2K chars
Historical Note Adopted effective March 30, 1981 (Supp. 81-2). R20-5-512 recodified from R4-13-512 (Supp. 95-1). Section expired under A.R.S. § 41-1056(E) at 11 A.A.R. 2320, effective May 19, 2005 (Supp. 05-2).
R20-5-513 Firefighters’ Emergency Operation
0.3K chars
All conveyances equipped with firefighters’ emergency operation shall utilize the AZFS key. Historical Note New Section made by final rulemaking at 15 A.A.R. 872, effective May 5, 2009 (Supp. 09-2). Amended by final rulemaking at 29 A.A.R. 512 (February 3, 2023), within an immedi…