RCSA 29-349-306 Width of aisles
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-306. Width of aislesAisles shall be provided to separate piles by a clear space of not less than 3 feet in width. At least one service or main aisle in the storage shall be not less than 4 feet in width. (Effective December 24,…
RCSA 29-349-307 Waiver for pile sizes
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-307. Waiver for pile sizesThe requirements for pile sizes and aisles, as set forth in Sections 29-349-305 and 29-349-306 may be waived by the State Fire Marshal where storage facilities are located in remote areas. (Effective D…
RCSA 29-349-308 Bulk storage by specific approval
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-308. Bulk storage by specific approvalBulk storage of ammonium nitrate shall be permitted only after specific approval by the Local or State Fire Marshal, who shall give due consideration to the location in regard to heavily po…
RCSA 29-349-309 Permissible bulk storage
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-309. Permissible bulk storageBulk storage may be in covered open piles, in bins, in warehouses, or in silo-type structures and shall totally exclude all other commodities of an organic, combustible or oxidizable nature. (Effect…
RCSA 29-349-310 Warehouse ventilation. Combustible construction
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-310. Warehouse ventilation. Combustible constructionWarehouses, if of combustible construction, shall have adequate ventilation or be capable of adequate ventilation in case of fire. (Effective December 24, 1987)
RCSA 29-349-311 Maximum height requirements
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-311. Maximum height requirementsUnless constructed of noncombustible material, bulk storage structures shall not exceed a height of 40 feet. (Effective December 24, 1987)
RCSA 29-349-312 Bin contamination
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-312. Bin contaminationBins shall be clear and free of materials which may contaminate ammonium nitrate.(Effective December 24, 1987)
RCSA 29-349-313 Prohibited bin construction materials
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-313. Prohibited bin construction materialsDue to corrosive and reactive properties of ammonium nitrate, and to avoid contamination, steel, galvanized iron, copper, lead and zinc shall not be used in bin construction unless suit…
RCSA 29-349-314 Warehouse subdivision
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-314. Warehouse subdivisionThe warehouse may be subdivided by tight partition walls into any desired number of ammonium nitrate storage compartments or bins. (Effective December 24, 1987)
RCSA 29-349-315 Identification signs
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-315. Identification signsThe ammonium nitrate storage bins or piles shall be clearly identified by signs reading \"AMMONIUM NITRATE\" with letters at least 2 inches high. (Effective December 24, 1987)
RCSA 29-349-316 Periodic moving of material
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-316. Periodic moving of materialPiles or bins shall be so sized and arranged that all material in the pile is moved out periodically in order to minimize possible caking of the stored ammonium nitrate. (Effective December 24, 1…
RCSA 29-349-317 Limitations of depth of piles
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-317. Limitations of depth of pilesHeight or depth of piles shall be limited by the pressure setting tendency of the product. However, in no case shall the ammonium nitrate be piled higher at any point than 36 inches below the r…
RCSA 29-349-318 Maximum temperature for storage
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-318. Maximum temperature for storageAmmonium nitrate shall not be accepted for storage when the temperature of the product exceeds 130°F. (Effective December 24, 1987)
RCSA 29-349-319 Use of explosives prohibited for loosening
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-319. Use of explosives prohibited for looseningDynamite, other explosives, and blasting agents shall not be used to break up or loosen caked ammonium nitrate. (Effective December 24, 1987)
RCSA 29-349-320 Wall construction requirements for separation
0.9K chars
Regulations of Connecticut State AgenciesSec. 29-349-320. Wall construction requirements for separationAmmonium nitrate shall be separated by approved type walls of not less than one hour fire-resistance rating from storage or organic chemicals, acids or corrosive liquids, or oth…
RCSA 29-349-321 Separation requirements with outwalls
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-321. Separation requirements with outwallsIn lieu of separation walls, ammonium nitrate may be separated from the materials referred to in the foregoing section by a space at least 30 feet or more as required by the Local or St…
RCSA 29-349-322 Flammable liquid storage prohibited
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-322. Flammable liquid storage prohibitedFlammable liquids such as gasoline, kerosene, solvents and light fuel oils shall not be stored on the premises except as approved by the State Fire Marshal. (Effective December 24, 1987)
RCSA 29-349-323 LP-Gas storage prohibited
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-323. LP-Gas storage prohibitedLP-Gas shall not be stored on the premises except as approved by the State Fire Marshal.(Effective December 24, 1987)
RCSA 29-349-324 Other materials storage restricted
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-324. Other materials storage restrictedSulphur and finely-divided metals shall not be stored in the same building with ammonium nitrate except as approved by the State Fire Marshal. (Effective December 24, 1987)
RCSA 29-349-325 Prohibited storage of explosives and blasting agents
0.9K chars
Regulations of Connecticut State AgenciesSec. 29-349-325. Prohibited storage of explosives and blasting agents(a) Explosives and blasting agents shall not be stored in the same building with ammonium nitrate except on the premises of makers, distributors and user-compounders of e…
RCSA 29-349-326 Electrical installations
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-326. Electrical installationsElectrical installations shall conform to the requirements of the National Electric Code. They shall be designed to minimize damage from corrosion. (Effective December 24, 1987)
RCSA 29-349-327 Electric light protection
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-327. Electric light protectionElectric lamps shall be located or guarded so as to preclude contact with bags or other combustible materials. (Effective December 24, 1987)
RCSA 29-349-328 Housekeeping
0.1K chars
Regulations of Connecticut State AgenciesSec. 29-349-328. HousekeepingGood housekeeping shall be maintained.(Effective December 24, 1987)
RCSA 29-349-329 Broken bag content salvage
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-329. Broken bag content salvageUncontaminated contents of broken bags may be salvaged by placing the damaged bag inside a clean, new slip-over bag and closing securely. Other spilled materials and discarded containers shall be …
RCSA 29-349-330 Open lights or flames and smoking prohibited
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-330. Open lights or flames and smoking prohibitedOpen lights or flames and smoking shall be prohibited in storage buildings, but this is not meant to exclude heating units approved by the State Fire Marshal. (Effective December…
RCSA 29-349-331 Entrances to warehouses to be properly identified
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-331. Entrances to warehouses to be properly identifiedAll points of entry to commercial warehouses in which ammonium nitrate is stored shall be properly identified with durable signs meeting the following specifications: (a) Si…
RCSA 29-349-332 Vehicle parking in buildings restricted
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-332. Vehicle parking in buildings restrictedInternal combustion motor vehicles, lift trucks and cargo conveyors shall not be permitted to remain overnight in a building where ammonium nitrate is stored unless parked in an area …
RCSA 29-349-333 Trucks inside warehouses to conform to requirements
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-333. Trucks inside warehouses to conform to requirementsFork trucks, tractors, platform lift trucks, and other specialized industrial trucks used within the warehouse shall conform to the requirements of the State Fire Marshal.…
RCSA 29-349-334 Lightning protection
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-334. Lightning protectionIn areas where lightning storms are prevalent, lightning protection shall be provided. See the Lightning Protection Code, NFPA No. 78. (Effective December 24, 1987)
RCSA 29-349-335 Unauthorized personnel
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-335. Unauthorized personnelProvisions shall be made to prevent unauthorized personnel from entering the ammonium nitrate storage area. (Effective December 24, 1987)
RCSA 29-349-336 Automatic sprinkler requirements
0.9K chars
Regulations of Connecticut State AgenciesSec. 29-349-336. Automatic sprinkler requirementsUnless the storage of a greater quantity is approved by the State Fire Marshal, not more than 2,500 tons of bagged ammonium nitrate shall be stored in a building or structure not equipped wi…
RCSA 29-349-337 Automatic sprinkler installation
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-337. Automatic sprinkler installationSprinkler systems shall be approved type and installed in accordance with the requirements of the State Fire Marshal. (Effective December 24, 1987)
RCSA 29-349-338 Portable fire extinguishers
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-338. Portable fire extinguishersSuitable fire control devices such as small hose or portable extinguishers shall be provided throughout the warehouse and in the loading and unloading areas as required by the State Fire Marshal.…
RCSA 29-349-339 Fire hydrants
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-339. Fire hydrantsWater supplies and fire hydrants shall be available in accordance with recognized good practices and as required by the State Fire Marshal. (Effective December 24, 1987)
RCSA 29-349-340 Sprinklers, hydrants may be waived
4.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-340. Sprinklers, hydrants may be waivedThe requirements for automatic sprinklers, water supplies and fire hydrants set forth in this Code may be waived by the State Fire Marshal when storage facilities are located in remote are…
RCSA 29-349-341 American Table of Distances
1.9K chars
Regulations of Connecticut State AgenciesSec. 29-349-341. American Table of DistancesThe following is the American Table of Distances for Storage of Explosives.American Table of Distances for Storage of ExplosivesExplosivesDistance in Feet When Storage is BarricadedPounds overPou…
RCSA 29-349-342 Existing Class B magazines
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-342. Existing Class B magazinesMagazines constructed and licensed prior to September 1, 1964 and used exclusively for the storage of Class B explosives may be located at one-half the distance specified in the table. (Effective …
RCSA 29-349-343 Non-barricaded magazines
0.2K chars
Regulations of Connecticut State AgenciesSec. 29-349-343. Non-barricaded magazinesWhen a building containing explosives is not barricaded, the distance shown in the table shall be doubled. (Effective December 24, 1987)
RCSA 29-349-344 Requirements for two or more magazines on same property
1.1K chars
Regulations of Connecticut State AgenciesSec. 29-349-344. Requirements for two or more magazines on same propertyWhen two or more storage magazines are located on the same property, each magazine must comply with the minimum distances specified from inhabited buildings, railways …
RCSA 29-349-345 Storage of explosives exceeding 300,000 pounds
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-345. Storage of explosives exceeding 300,000 poundsThe permanent storage of more than 300,000 pounds of commercial explosives in one magazine or in a group of magazines which is considered as one magazine is not permitted excep…
RCSA 29-349-346 Explosive rating of blasting caps
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-346. Explosive rating of blasting capsAll types of blasting caps in strength through No. 8 shall be rated at 1½ pounds of explosives per 1,000 caps. The State Fire Marshal shall designate the ratings of caps higher in strength …
RCSA 29-349-347 General provisions
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-347. General provisionsUnless otherwise set forth in this chapter, water gels shall be transported, stored and used in the same manner as explosives or blasting agents in accordance with the classification of the product. (Effe…
RCSA 29-349-348 Premixed water gels
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-348. Premixed water gelsPremixed water gels containing a substance in itself classified as an explosive shall be classified as an explosive and manufactured, transported, stored, and used as specified for explosives in this Cod…
RCSA 29-349-349 Cap-sensitive premixed water gels
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-349. Cap-sensitive premixed water gelsPremixed water gels containing no substance in itself classified as an explosive and which are cap-sensitive as defined in Section 29-349-106 of this Code under Blasting Agent shall be clas…
RCSA 29-349-350 Non cap-sensitive premixed water gels
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-350. Non cap-sensitive premixed water gelsPremixed water gels containing no substance in itself classified as an explosive and which are NOT cap-sensitive as defined in Section 29-349-106 of this Code under Blasting Agent shall…
RCSA 29-349-351 On-site mixed water gels
1.1K chars
Regulations of Connecticut State AgenciesSec. 29-349-351. On-site mixed water gelsIngredients for on-site mixed water gels shall be stored as set forth in this section.(a) Ingredients in themselves classified as Class A or Class B explosives shall be stored in conformity with Cha…
RCSA 29-349-352 Electric power sources
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-352. Electric power sourcesIf electric power is used it may be furnished by cable from an outside source or by a self-contained motor generator. In the case of a self-contained power source, it shall be located at the end of th…
RCSA 29-349-353 Electric wiring requirements
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-353. Electric wiring requirementsElectric wiring carrying voltages greater than 21 volts shall be armored or in conduit and, if dry ingredients are employed, the wiring shall conform to the requirements of Class II, Division 2 …
RCSA 29-349-354 Mixing equipment requirements
0.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-354. Mixing equipment requirementsMixing equipment for on-site mixed water gels shall comply with the requirements of this section. (a) All electric motors, electrically operated proportioning devices, etc., shall be electrical…
RCSA 29-349-355 General provisions
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-355. General provisionsIn addition to all other applicable requirements in this Code, the intrastate transportation of small arms ammunition, small arms ammunition primers and smokelss propellants shall be in accordance with cu…