RCSA 29-349-222 Minimum current
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-222. Minimum currentA circuit shall not be fired electrically with less than the minimum current specified by the manufacturer. (Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AUTHORITY: Conn. Gen. Stat. § 29…
RCSA 29-349-223 Blasting cap containers
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-223. Blasting cap containersElectric blasting caps shall be kept in their original container or in a closed metal box lined with a soft material such as wood or sponge rubber. The coils and folds in the wires of electric blasti…
RCSA 29-349-224 Extraneous electricity hazards
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-224. Extraneous electricity hazardsBlasting areas shall be surveyed for possible hazards caused by extraneous electricity. Non electric initiation shall be used if a current testing device shows more than 0.06 ampere. (Effectiv…
RCSA 29-349-225 Drill hole size
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-225. Drill hole sizeAll drill holes shall be sufficiently large to admit freely the insertion of the cartridges of explosives. (Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AUTHORITY: Conn. Gen. Stat. § 29-…
RCSA 29-349-226 Tamping
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-226. TampingTamping shall be done only with wood rods without exposed metal joints, but non-sparking metal connectors may be used for jointed poles. Plastic tamping poles may be used, provided they have been approved by the Sta…
RCSA 29-349-227 Loading of holes
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-227. Loading of holesNo holes shall be loaded except those to be fired in the next round of blasting. After loading, all remaining explosives shall be immediately returned to an authorized magazine. (Effective December 24, 1987…
RCSA 29-349-228 Examination for unexploded explosives
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-228. Examination for unexploded explosivesDrilling shall not be started until all remaining butts of old holes are examined for unexploded charges, and if any are found, they shall be handled by or under the supervision of a co…
RCSA 29-349-229 Deepening drill holes
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-229. Deepening drill holesNo person shall deepen drill holes which have contained explosives.(Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AUTHORITY: Conn. Gen. Stat. § 29-349
RCSA 29-349-230 Loading holes completed—return explosives to magazine
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-230. Loading holes completed—return explosives to magazineAfter loading for a blast is completed, all excess blasting caps or electric blasting caps and other explosives shall immediately be returned to their separate storage m…
RCSA 29-349-231 Fuses. Length
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-231. Fuses. LengthSafety fuse shall be cut sufficiently long to extend beyond the collar of the hole, and sufficient in length to assure ample time in retiring from the blast, and shall be not less than three feet in length. (E…
RCSA 29-349-232 Fuses into cap
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-232. Fuses into capSafety fuse shall be cut squarely across and not at a slant. At least one inch of safety fuse shall be cut off, and the freshly cut end immediately inserted into the blasting cap and crimped with a standard c…
RCSA 29-349-233 Cartridges
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-233. CartridgesCartridges for use in blasting shall be primed only as required for immediate use.(Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AUTHORITY: Conn. Gen. Stat. § 29-349
RCSA 29-349-234 Leading wires
0.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-234. Leading wiresRubber covered or equally insulated wires in good condition shall be used for leading wires. Permanent lines shall be properly supported and insulated and of sufficient size to provide theoretical current requ…
RCSA 29-349-235 Equipment of blaster
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-235. Equipment of blasterEach blaster shall be equipped with a galvanometer and blasting machine in good working order; and shall be further equipped with fuse cutters and cap crimpers if cap and fuse is used. (Effective Decemb…
RCSA 29-349-236 Short circuiting leading wires
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-236. Short circuiting leading wiresPrior to firing shots electrically, the leading wires shall be kept short circuited until ready to actually fire the shot. (Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AU…
RCSA 29-349-237 Testing of circuits
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-237. Testing of circuitsBlasters, when testing circuits to charge holes, shall use only blasting galvanometers designed for this purpose. (Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AUTHORITY: Conn. Gen. …
RCSA 29-349-238 Loading and drilling restricted
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-238. Loading and drilling restrictedNo loading operation shall be conducted within 25 feet of a drilling operation.(Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AUTHORITY: Conn. Gen. Stat. § 29-349
RCSA 29-349-239 Springing holes
0.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-239. Springing holesDrill holes shall not be sprung unless they are more than 100 feet from the nearest hole containing explosives. Holes that have been sprung shall not be charged with explosives until the maximum temperature …
RCSA 29-349-240 Stemming
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-240. StemmingStemming shall consist of clean fine clay, sand or crushed rock screenings. The use of leaves or trash is prohibited. Each blast hole shall be stemmed to the collar or to a point high enough to provide sufficient c…
RCSA 29-349-241 Misfire. Suspected
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-241. Misfire. SuspectedIf a misfire is suspected, all wires or commercial detonating fuse in broken rock shall be carefully traced and search made for unexploded cartridges. If recovery is not made, the Local Fire Marshal shall…
RCSA 29-349-242 Misfire. Investigation
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-242. Misfire. InvestigationNo person shall be permitted to examine a shot after a misfire until specifically authorized by the person in charge of the blasting operations. If practicable, the misfired charge shall be re-primed …
RCSA 29-349-243 Misfire. Precautions
0.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-243. Misfire. PrecautionsIf a misfire occurs or is suspected, no person shall return to the victinity of the misfire until at least one hour after the misfire if the shot was cap and fuse firing, or minimum of 30 minutes for el…
RCSA 29-349-244 Airline hose prohibited within twenty-five feet
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-244. Airline hose prohibited within twenty-five feetIn no case shall an airline hose be permitted to be located within 25 feet of a loading operation or a space where explosives are stored or handled. (Effective December 24, 19…
RCSA 29-349-245 Loaded holes to be guarded. Warning whistle
0.7K chars
Regulations of Connecticut State AgenciesSec. 29-349-245. Loaded holes to be guarded. Warning whistleWhen a charge of explosives has been loaded there shall be a constant guard over same until the blast is fired. Before a blast is fired, a loud warning signal shall be given by th…
RCSA 29-349-246 Blasting caps in congested areas
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-246. Blasting caps in congested areasOnly electric blasting caps or commercial detonating fuse shall be used for blasting operations in congested districts, or on highways, or adjacent to highways open to traffic, except where …
RCSA 29-349-247 Cap crimpers
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-247. Cap crimpersWhen fuse is used, the blasting cap shall be securely attached to the fuse with a standard ring type cap crimper. All primers shall be assembled at least 50 feet from any magazine. (Effective December 24, 1987)…
RCSA 29-349-248 Accidents, thefts, fires to be reported
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-248. Accidents, thefts, fires to be reportedAll accidents, thefts or fires occurring with the use of explosives shall be reported to the Local Fire Marshal immediately by verbal communication and, within 24 hours, shall report …
RCSA 29-349-249 Inserting. Blasting caps
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-249. Inserting. Blasting capsNo blasting cap shall be inserted in the explosives without first making a hole in the cartridge for the cap with a wooden or non-ferrous metal punch of proper size or standard cap crimper. (Effecti…
RCSA 29-349-250 Misfired explosives, not to be dug out
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-250. Misfired explosives, not to be dug outExplosives shall not be extracted from a hole that has once been charged or has misfired unless it is impossible to safely detonate the unexploded charge by insertion of a fresh additi…
RCSA 29-349-251 Lead wire connector to fire shot
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-251. Lead wire connector to fire shotOnly the man making leading wire connections in electric firing shall fire the shot. All connections should be made from bore hole back to the source of the firing current, and the leading w…
RCSA 29-349-252 Extraneous electricity. Precautions
1.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-252. Extraneous electricity. PrecautionsDue precautions shall be taken to prevent accidental discharge of electric blasting caps from current induced by radar, radio transmitters, adjacent power lines, lightning, dust storms an…
RCSA 29-349-253 Railroad cars
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-253. Railroad carsExcept in an emergency, and with the permission of the State Fire Marshal, no person shall have or keep explosives in a railway car unless said car and contents and methods of loading are in accordance with th…
RCSA 29-349-254 Packing to conform to D.O.T. regulations
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-254. Packing to conform to D.O.T. regulationsNo person shall deliver any explosives to any carrier unless such explosive conforms in all respects, including marking and packaging to the U.S. Department of Transportation regulat…
RCSA 29-349-255 Warning signs
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-255. Warning signsEvery railway car containing explosives which has reached its destination, or is stopped in transit so as no longer to be in interstate commerce shall have attached to both sides and ends of the car, cards wit…
RCSA 29-349-256 Explosives to be isolated at terminals
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-256. Explosives to be isolated at terminalsAny explosives at a railway facility, truck terminal, pier, wharf, harbor facility or airport terminal whether for delivery to a consignee or forwarded to some other destination shall …
RCSA 29-349-257 Delivery between sunset and sunrise
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-257. Delivery between sunset and sunriseExplosives shall not be delivered to or received from any railway station, truck terminal, pier, wharf, harbor facility or airport terminal between the hours of sunset and sunrise without…
RCSA 29-349-258 Unclaimed or undelivered explosives
0.7K chars
Regulations of Connecticut State AgenciesSec. 29-349-258. Unclaimed or undelivered explosivesWhenever explosives brought into this State by any means of transportation for delivery to an intermediate receiver, consignee's agent or consignee, or to be forwarded to some other desti…
RCSA 29-349-259 Consignee to remove explosives
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-259. Consignee to remove explosivesAny person having been notified, as consignee, of a shipment of explosives being in the hands of any carrier shall remove the said explosives within 48 hours, Sundays and holidays excluded, af…
RCSA 29-349-260 Authority to designate location and quantity of explosives
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-260. Authority to designate location and quantity of explosivesThe Local Fire Marshal has the authority to and may designate the location for, and limit the quantity of, explosives which may be loaded, unloaded, reloaded, or te…
RCSA 29-349-261 Permits for waterfront facilities
1.1K chars
Regulations of Connecticut State AgenciesSec. 29-349-261. Permits for waterfront facilitiesBefore the owner or operator of a waterfront facility shall handle, load, discharge, transport on or over such facility any Class A explosive in any quantity, he shall hold a permit issued …
RCSA 29-349-262 Application of regulations
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-262. Application of regulationsUnless otherwise set forth in these regulations, blasting agents shall be transported, stored and used in the same manner as explosives. (Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. §…
RCSA 29-349-263 Facilities used for mixing blasting agents
1.0K chars
Regulations of Connecticut State AgenciesSec. 29-349-263. Facilities used for mixing blasting agents(a) Buildings or other facilities used for mixing blasting agents shall be located, with respect to inhabited buildings, passenger railroads and public highways, in accordance with…
RCSA 29-349-264 Buildings used for mixing of blasting agents
1.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-264. Buildings used for mixing of blasting agents(a) Buildings used for the mixing of blasting agents shall conform to the requirements of this section, unless otherwise specifically approved by the State Fire Marshal. (b) Buil…
RCSA 29-349-265 Mixer design
0.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-265. Mixer designThe design of the mixer shall be such as to minimize the possibility of frictional heating, compaction, and especially confinement. Open mixers are preferable to enclosed mixers. Bearing and gears should be pro…
RCSA 29-349-266 Determination of blasting agent compositions
1.6K chars
Regulations of Connecticut State AgenciesSec. 29-349-266. Determination of blasting agent compositionsThe provisions of this section shall be considered when determining blasting agent compositions. The sensitivity of the blasting agent shall be determined by means of a No. 8 tes…
RCSA 29-349-267 Power sources for mixing plants
0.9K chars
Regulations of Connecticut State AgenciesSec. 29-349-267. Power sources for mixing plants(a) All electrical switches, controls, motors, and lights, if located in the mixing rooms shall conform to the requirements of Class II, Division 2 of the National Electrical Code; otherwise …
RCSA 29-349-268 Washdown facilities
0.8K chars
Regulations of Connecticut State AgenciesSec. 29-349-268. Washdown facilitiesAn automatic water-deluge system with adequate capacity shall be provided to protect mixers and the finished-explosives storage area in permanently located plants. Floors shall be constructed so as to el…
RCSA 29-349-269 Smoking prohibited
0.3K chars
Regulations of Connecticut State AgenciesSec. 29-349-269. Smoking prohibitedSmoking or open flames shall not be permitted in or within 50 feet of any building or facility used for the mixing of blasting agents. (Effective December 24, 1987) AUTHORITY: Conn. Gen. Stat. § 29-349 AU…
RCSA 29-349-270 Disposal of nitrate bags
0.4K chars
Regulations of Connecticut State AgenciesSec. 29-349-270. Disposal of nitrate bagsEmpty ammonium nitrate bags shall be disposed of daily by burning in small quantities in a safe location. No person shall remain within 100 feet once the burning has started. (Effective December 24,…
RCSA 29-349-271 Limited production
0.5K chars
Regulations of Connecticut State AgenciesSec. 29-349-271. Limited productionNot more than one day's production of blasting agents or the limit determined by the American Table of Distances, whichever is less, shall be permitted in or near the mixing and packaging plant or area. L…