210 sections in this chapter.
HAR 11-264-90 Applicability
4.4K chars
(a) Applicability. (1) Except as provided in subsection (b), the rules in this subchapter apply to owners or operators of facilities that treat, store or dispose of hazardous waste. The owner or operator must satisfy the requirements identified in paragraph (a)(2) for all wastes …
HAR 11-264-91 Required programs
2.1K chars
(a) Owners and operators subject to this subchapter must conduct a monitoring and response program as follows: (1) Whenever hazardous constituents under section 11-264-93 from a regulated unit are detected at a compliance point under section 11-264-95, the owner or operator must …
HAR 11-264-92 Ground-water protection standard
0.7K chars
The owner or operator must comply with conditions specified in the facility permit that are designed to ensure that hazardous constituents under section 11-264-93 detected in the ground water from a regulated unit do not exceed the concentration limits under section 11-264-94 in …
HAR 11-264-93 Hazardous constituents
3.2K chars
(a) The director will specify in the facility permit the hazardous constituents to which the ground-water protection standard of section 11-264-92 applies. Hazardous constituents are constituents identified in Appendix VIII of chapter 11-261 that have been detected in ground wate…
HAR 11-264-94 Concentration limits
4.1K chars
(a) The director will specify in the facility permit concentration limits in the ground water for hazardous constituents established under section 11-264-93. The concentration of a hazardous constituent: (1) Must not exceed the background level of that constituent in the ground w…
HAR 11-264-95 Point of compliance
1.0K chars
(a) The director will specify in the facility permit the point of compliance at which the ground-water protection standard of section 11-264-92 applies and at which monitoring must be conducted. The point of compliance is a vertical surface located at the hydraulically down-gradi…
HAR 11-264-96 Compliance period
1.0K chars
(a) The director will specify in the facility permit the compliance period during which the ground-water protection standard of section 11-264-92 applies. The compliance period is the number of years equal to the active life of the waste management area (including any waste manag…
HAR 11-264-97 General ground-water monitoring requirements
9.2K chars
The owner or operator must comply with the following requirements for any ground-water monitoring program developed to satisfy 11-264-98, 11-264-99, or 11-264-100: (a) The ground-water monitoring system must consist of a sufficient number of wells, installed at appropriate locati…
HAR 11-264-98 Detection monitoring program
8.6K chars
An owner or operator required to establish a detection monitoring program under this subchapter must, at a minimum, discharge the following responsibilities: (a) The owner or operator must monitor for indicator parameters (e.g., specific conductance, total organic carbon, or tota…
HAR 11-264-99 Compliance monitoring program
7.0K chars
An owner or operator required to establish a compliance monitoring program under this subchapter must, at a minimum, discharge the following responsibilities: (a) The owner or operator must monitor the ground water to determine whether regulated units are in compliance with the g…