212 sections in this chapter.
HAR 11-265-1 Containment system
0.3K chars
All earthen dikes must have a protective cover, such as grass, shale, or rock, to minimize wind and water erosion and to preserve their structural integrity. Notes Haw. Code R. § 11-265-222.1 [Eff 6/18/94; comp] (Auth: HRS §§ 342J-4, 342J-31, 342J-34, 342J-35) (Imp: 40 C.F.R. §26…
HAR 11-265-10 Applicability
0.3K chars
The rules in this subchapter apply to owners and operators of all hazardous waste facilities, except as section 11-265-1 provides otherwise. Notes Haw. Code R. § 11-265-10 [Eff 6/18/94; comp] (Auth: HRS §§ 342J-4, 342J-31, 342J-34, 342J-35) (Imp: 40 C.F.R. §265.10)
HAR 11-265-1030 Applicability
2.2K chars
(a) The rules in this subchapter apply to owners and operators of facilities that treat, store, or dispose of hazardous wastes (except as provided in section 11-265-1). (b) Except for subsections 11-265-1034(d) and 11-265-1034(e), this subchapter applies to process vents associat…
HAR 11-265-1031 Definitions
0.3K chars
As used in this subchapter, all terms shall have the meaning given them in section 11-264-1031, HRS chapter 342J, and chapters 11-260 through 11-266. Notes Haw. Code R. § 11-265-1031 [Eff 6/18/94; comp] (Auth: HRS §§ 342J-4, 342J-31, 342J-34, 342J-35) (Imp: 40 C.F.R. §265.1031)…
HAR 11-265-1032 Standards: Process vents
1.7K chars
(a) The owner or operator of a facility with process vents associated with distillation, fractionation, thin-film evaporation, solvent extraction or air or steam stripping operations managing hazardous wastes with organic concentrations at least 10 ppmw shall either: (1) Reduce t…
HAR 11-265-1033 Standards: Closed-vent systems and control devices
22.1K chars
(a) (1) Owners or operators of closed-vent systems and control devices used to comply with provisions of this chapter shall comply with the provisions of this section. (2) (i) The owner or operator of an existing facility who cannot install a closed-vent system and control device…
HAR 11-265-1034 Test methods and procedures
8.9K chars
(a) Each owner or operator subject to the provisions of this subchapter shall comply with the test methods and procedures requirements provided in this section. (b) When a closed-vent system is tested for compliance with no detectable emissions, as required in subsection 11-265-1…
HAR 11-265-1035 Recordkeeping requirements
16.7K chars
(a) (1) Each owner or operator subject to the provisions of this subchapter shall comply with the recordkeeping requirements of this section. (2) An owner or operator of more than one hazardous waste management unit subject to the provisions of this subchapter may comply with the…
HAR 11-265-1036 11-265-1049 - Reserved
0.0K chars
Notes Haw. Code R. § 11-265-1036 - 11-265-1049
HAR 11-265-1050 Applicability
2.1K chars
(a) The rules in this subchapter apply to owners and operators of facilities that treat, store, or dispose of hazardous wastes (except as provided in section 11-265-1). (b) Except as provided in subsection 11-265-1064(k), this subchapter applies to equipment that contains or cont…
HAR 11-265-1051 Definitions
0.3K chars
As used in this subchapter, all terms shall have the meaning given them in section 11-264-1031, HRS chapter 342J, and chapters 11-260 through 11-266. Notes Haw. Code R. § 11-265-1051 [Eff 6/18/94; comp] (Auth: HRS §§ 342J-4, 342J-31, 342J-34, 342J-35) (Imp: 40 C.F.R. §265.1051)…
HAR 11-265-1052 Standards: Pumps in light liquid service
4.0K chars
(a) (1) Each pump in light liquid service shall be monitored monthly to detect leaks by the methods specified in subsection 11-265-1063(b), except as provided in subsections (d), (e), and (f). (2) Each pump in light liquid service shall be checked by visual inspection each calend…
HAR 11-265-1053 Standards: Compressors
3.1K chars
(a) Each compressor shall be equipped with a seal system that includes a barrier fluid system and that prevents leakage of total organic emissions to the atmosphere, except as provided in subsections (h) and (i). (b) Each compressor seal system as required in subsection (a) shall…
HAR 11-265-1054 Standards: Pressure relief devices in gas/vapor service
1.4K chars
(a) Except during pressure releases, each pressure relief device in gas/vapor service shall be operated with no detectable emissions, as indicated by an instrument reading of less than five-hundred ppm above background, as measured by the method specified in subsection 11-265-106…
HAR 11-265-1055 Standards: Sampling connecting systems
1.1K chars
(a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed-vent system. This system shall collect the sample purge for return to the process or for routing to the appropriate treatment system. Gases displaced during filling of the sample con…
HAR 11-265-1056 Standards: Open-ended valves or lines
0.9K chars
(a) (1) Each open-ended valve or line shall be equipped with a cap, blind flange, plug, or a second valve. (2) The cap, blind flange, plug, or second valve shall seal the open end at all times except during operations requiring hazardous waste stream flow through the open-ended v…
HAR 11-265-1057 Standards: Valves in gas/vapor service or in light liquid service
3.2K chars
(a) Each valve in gas/vapor or light liquid service shall be monitored monthly to detect leaks by the methods specified in subsection 11-265-1063(b) and shall comply with subsections (b) through (e), except as provided in subsections (f), (g), and (h) and sections 11-265-1061 and…
HAR 11-265-1058 Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other connectors
1.2K chars
(a) Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and flanges and other connectors shall be monitored within five days by the method specified in subsection 11-265-1063(b) if evidence of a potential leak is found by vis…
HAR 11-265-1059 Standards: Delay of repair
1.9K chars
(a) Delay of repair of equipment for which leaks have been detected will be allowed if the repair is technically infeasible without a hazardous waste management unit shutdown. In such a case, repair of this equipment shall occur before the end of the next hazardous waste manageme…
HAR 11-265-1060 Standards: Closed-vent systems and control devices
2.8K chars
(a) Owners and operators of closed-vent systems and control devices subject to this subchapter shall comply with the provisions of section 11-265-1033. (b) (1) The owner or operator of an existing facility who can not install a closed-vent system and control device to comply with…
HAR 11-265-1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak
1.9K chars
(a) An owner or operator subject to the requirements of section 11-265-1057 may elect to have all valves within a hazardous waste management unit comply with an alternative standard which allows no greater than two percent of the valves to leak. (b) The following requirements sha…
HAR 11-265-1062 Alternative standards for valves in gas/vapor service or in light liquid service: skip period leak detection and repair
1.6K chars
(a) (1) An owner or operator subject to the requirements of section 11-265-1057 may elect for all valves within a hazardous waste management unit to comply with one of the alternative work practices specified in paragraphs (b) (2) and (b) (3). (2) An owner or operator must notify…
HAR 11-265-1063 Test methods and procedures
4.4K chars
(a) Each owner or operator subject to the provisions of this subchapter shall comply with the test methods and procedures requirements provided in this section. (b) Leak detection monitoring, as required in sections 11-265-1052 through 11-265-1062, shall comply with the following…
HAR 11-265-1064 Recordkeeping requirements
9.8K chars
(a) (1) Each owner or operator subject to the provisions of this subchapter shall comply with the recordkeeping requirements of this section. (2) An owner or operator of more than one hazardous waste management unit subject to the provisions of this subchapter may comply with the…
HAR 11-265-1065 11-265-1079 - Reserved
0.0K chars
Notes Haw. Code R. § 11-265-1065 - 11-265-1079
HAR 11-265-1080 Applicability
5.4K chars
(a) The requirements of this subchapter apply to owners and operators of all facilities that treat, store, or dispose of hazardous waste in tanks, surface impoundments, or containers subject to either subchapter I, J, or K except as section 11-265-1 and subsection (b) provide oth…
HAR 11-265-1081 Definitions
10.2K chars
As used in this subchapter, all terms not defined herein shall have the meaning given to them by chapter 342J, HRS and chapters 11-260 through 11-266 of the Hawaii Administrative Rules. "Average volatile organic concentration" or "average VO concentration" means the mass-weighted…
HAR 11-265-1082 Schedule for implementation of air emission standards
3.2K chars
(a) Owners or operators of facilities existing on December 6, 1996, and subject to subchapters I, J, and K shall meet the following requirements: (1) Install and begin operation of all control equipment or waste management units required to comply with this subchapter and complet…
HAR 11-265-1083 Standards: General
14.1K chars
(a) This section applies to the management of hazardous waste in tanks, surface impoundments, and containers subject to this subchapter. (b) The owner or operator shall control air pollutant emissions from each hazardous waste management unit in accordance with standards specifie…
HAR 11-265-1084 Waste determination procedures
37.9K chars
(a) Waste determination procedure to determine average volatile organic (VO) concentration of a hazardous waste at the point of waste origination. (1) An owner or operator shall determine the average VO concentration at the point of waste origination for each hazardous waste plac…
HAR 11-265-1085 Standards: Tanks
37.9K chars
(a) The provisions of this section apply to the control of air pollutant emissions from tanks for which section 11-265-1083(b) references the use of this section for such air emission control. (b) The owner or operator shall control air pollutant emissions from each tank subject …
HAR 11-265-1086 Standards: surface impoundments
13.7K chars
(a) The provisions of this section apply to the control of air pollutant emissions from surface impoundments for which section 11-265-1083(b) references the use of this section for such air emission control. (b) The owner or operator shall control air pollutant emissions from the…
HAR 11-265-1087 Standards: Containers
25.0K chars
(a) The provisions of this section apply to the control of air pollutant emissions from containers for which section 11-265-1083(b) references the use of this section for such air emission control. (b) General requirements. (1) The owner or operator shall control air pollutant em…
HAR 11-265-1088 Standards: Closed-vent systems and control devices
9.1K chars
(a) This section applies to each closed-vent system and control device installed and operated by the owner or operator to control air emissions in accordance with standards of this subchapter. (b) The closed-vent system shall meet the following requirements: (1) The closed-vent s…
HAR 11-265-1089 Inspection and monitoring requirements
0.6K chars
(a) The owner or operator shall inspect and monitor air emission control equipment used to comply with this subchapter in accordance with the applicable requirements specified in sections 11-265-1085 through 11-265-1088. (b) The owner or operator shall develop and implement a wri…
HAR 11-265-1090 Recordkeeping requirements
16.3K chars
(a) Each owner or operator of a facility subject to requirements in this subchapter shall record and maintain the information specified in subsections (b) through (j), as applicable to the facility. Except for air emission control equipment design documentation and information re…
HAR 11-265-1091 Reserved
0.0K chars
Notes Haw. Code R. § 11-265-1091
HAR 11-265-11 Identification number
0.3K chars
Every facility owner or operator must apply to the State for an EPA identification number in accordance with the State notification procedures. Notes Haw. Code R. § 11-265-11 [Eff 6/18/94; comp] (Auth: HRS §§ 342J-4, 342J-31, 342J-34, 342J-35) (Imp: 40 C.F.R. §265.11)
HAR 11-265-110 Applicability
0.9K chars
Except as section 11-265-1 provides otherwise: (a) Sections 11-265-111 through 11-265-115 (which concern closure) apply to the owners and operators of all hazardous waste management facilities; and (b) Sections 11-265-116 through 11-265-120 (which concern post-closure care) apply…
HAR 11-265-1100 Applicability
2.1K chars
The requirements of this subchapter apply to owners or operators who store or treat hazardous waste in units designed and operated under section 11-265-1101. The owner or operator is not subject to the definition of land disposal in chapter 11-260 provided that the unit: (a) Is a…
HAR 11-265-1101 Design and operating standards
10.9K chars
(a) All containment buildings must comply with the following design standards: (1) The containment building must be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements, (e.g., precipitation, wind, run-on), and to assure containment of managed w…
HAR 11-265-1102 Closure and post-closure care
1.5K chars
(a) At closure of a containment building, the owner or operator must remove or decontaminate all waste residues, contaminated containment system components (liners, etc.), contaminated subsoils, and structures and equipment contaminated with waste and leachate, and manage them as…
HAR 11-265-1103 11-265-1110 - Reserved
0.0K chars
Notes Haw. Code R. § 11-265-1103 - 11-265-1110
HAR 11-265-111 Closure performance standard
0.8K chars
The owner or operator must close the facility in a manner that: (a) Minimizes the need for further maintenance, and (b) Controls, minimizes or eliminates, to the extent necessary to protect human health and the environment, post-closure escape of hazardous waste, hazardous consti…
HAR 11-265-112 Closure plan; amendment of plan
12.0K chars
(a) Written plan. By six months after the effective date of the rule that first subjects a facility to provisions of this section, the owner or operator of a hazardous waste management facility must have a written closure plan. Until final closure is completed and certified in ac…
HAR 11-265-113 Closure; time allowed for closure
10.3K chars
(a) Within ninety days after receiving the final volume of hazardous wastes, or the final volume of non-hazardous wastes if the owner or operator complies with all applicable requirements in subsections (d) and (e), at a hazardous waste management unit or facility, or within nine…
HAR 11-265-114 Disposal or decontamination of equipment
0.6K chars
During the partial and final closure periods, all contaminated equipment, structures and soil must be properly disposed of, or decontaminated unless specified otherwise in sections 11-265-197, 11-265-228, 11-265-258, 11-265-280, or 11-265-310. By removing all hazardous wastes or …
HAR 11-265-115 Certification of closure
1.0K chars
Within sixty days of completion of closure of each hazardous waste surface impoundment, waste pile, land treatment, and landfill unit, and within sixty days of completion of final closure, the owner or operator must submit to the director, by registered mail, a certification that…
HAR 11-265-116 Survey plat
0.9K chars
No later than the submission of the certification of closure of each hazardous waste disposal unit, an owner or operator must submit to the local zoning authority, or the authority with jurisdiction over local land use, and to the director, a survey plat indicating the location a…
HAR 11-265-117 Post-closure care and use of property
2.8K chars
(a) (1) Post-closure care for each hazardous waste management unit subject to the requirements of sections 11-265-117 through 11-265-120 must begin after completion of closure of the unit and continue for thirty years after that date. It must consist of at least the following: (i…