237 sections in this chapter.
R.890.750 Section 890.750: Hydromassage/Whirlpool Bathtubs
0.6K chars
Section 890.750 Hydromassage/Whirlpool Bathtubs a) Whirlpool bathtubs shall be installed so that the tub, pump, jets and pump tubing drain completely after each use. The pump shall be located above the weir of the whirlpool tub trap. b) All whirlpool bathtubs shall comply with AS…
R.890.760 Section 890.760: Pressure Type Water Treatment Units
0.8K chars
Section 890.760 Pressure Type Water Treatment Units Wash water and rinse water drain lines from water softeners and other types of water treatment units shall discharge through a vertical air gap at least twice the diameter of the pipe, but not less than two (2) inches. Any water…
R.890.770 Section 890.770: Dishwashing Machines
1.4K chars
Section 890.770 Dishwashing Machines a) Domestic Dishwasher (Private Residence). When a domestic dishwashing machine drain line is connected to the house side of a trap from a sink, the drain from the dishwasher shall be carried up to the underside of the spill rim of the sink. D…