21,144 sections across 2,050 Iowa regulatory chapters.
R.567—101.207 Hydrogeologic investigation
4.9K chars
101.207(1) Groundwater level measurements. The elevation of the water table shall be determined at or near the location of each soil boring that penetrates the water table. The water table may be determined using a completed water table monitoring well, or piezometer. The bottom …
R.567—101.208 Evaluation of hydrogeologic conditions
2.3K chars
101.208(1) Based on soil boring and other available information, a description of the landfill site geology shall be made. This description shall include preparation of geologic cross sections of sufficient number and spacing (no fewer than four at every landfill site) to adequat…
R.567—101.209 Monitoring system plan. A hydrologic monitoring system shall be designed to
0.7K chars
intercept the groundwater and surface water flow paths from the landfill site, including proposed locations and depths for monitoring wells in accordance with monitoring well siting criteria in 567—101.212(455B). The surface water monitoring plan shall include monitoring points o…