189 sections in this chapter.
Chapter 43. Interim Status-4559 Recordkeeping Requirements
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1713.
Chapter 43. Interim Status-4561 Applicability
2.3K chars
A. The regulations in this Subchapter apply to owners and operators of facilities that treat, store, or dispose of hazardous wastes (except as provided in LAC 33:V.4307). B. Except as provided in LAC 33:V.1743.K, as referenced in LAC 33:V.4509, this Subchapter applies to equipmen…
Chapter 43. Interim Status-4563 Definitions
0.1K chars
A. As used in this Subchapter, all terms shall have the meanings given them in LAC 33:V.1703.
Chapter 43. Interim Status-4565 Standard: Pumps in Light Liquid Service
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1719.
Chapter 43. Interim Status-4567 Standard: Compressors
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1721.
Chapter 43. Interim Status-4569 Standards: Pressure Relief Devices in Gas/Vapor Service
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1723.
Chapter 43. Interim Status-4571 Standards: Sampling Connection Systems
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1725.
Chapter 43. Interim Status-4573 Standards: Open-Ended Valves or Lines
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1727.
Chapter 43. Interim Status-4575 Standards: Valves in Gas/Vapor Service or in Light Liquid Service
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1729.
Chapter 43. Interim Status-4577 Standards: Pumps and Valves in Heavy Liquid Service, Pressure Relief Devices in Light Liquid or Heavy Liquid Service, and Flanges and Other Connectors
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1731.
Chapter 43. Interim Status-4579 Standards: Delay of Repair
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1733.
Chapter 43. Interim Status-4581 Standards: Closed-Vent Systems and Control Devices
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1735.
Chapter 43. Interim Status-4583 Alternative Standards for Valves in Gas/Vapor Service or in Light Liquid Service: Percentage of Valves Allowed to Leak
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1737.
Chapter 43. Interim Status-4585 Alternative Standards for Valves in Gas/Vapor Service or in Light Liquid Service: Skip Period Leak Detection and Repair
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1739.
Chapter 43. Interim Status-4587 Test Methods and Procedures
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1741.
Chapter 43. Interim Status-4589 Recordkeeping Requirements
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1743.
Chapter 43. Interim Status-4591 Applicability
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.2801.
Chapter 43. Interim Status-4593 Assessment of Existing Drip Pad Integrity
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.2803.
Chapter 43. Interim Status-4595 Design and Installation of New Drip Pads
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.2811.
Chapter 43. Interim Status-4597 Design and Operating Requirements
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.2805.
Chapter 43. Interim Status-4599 Inspections
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.2807.
Chapter 43. Interim Status-4601 Closure
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.2809.
Chapter 43. Interim Status-4701 Applicability
1.9K chars
A. The requirements of this Subchapter apply to owners or operators who store or treat hazardous waste in units designed and operated under LAC 33:V.4703. The owner or operator is not subject to the definition of land disposal in RCRA Section 3004(k) provided that the unit: 1. is…
Chapter 43. Interim Status-4703 Design and Operating Standards
10.4K chars
A. All containment buildings must comply with the following design standards: 1. the containment building must be completely enclosed with a floor, walls, and a roof to prevent exposure to the elements, (e.g., precipitation, wind, run-on) and to ensure containment of managed wast…
Chapter 43. Interim Status-4705 Closure and Post-Closure Care
1.7K chars
A. At closure of a containment building, the owner or operator must remove or decontaminate all waste residues, contaminated containment system components (liners, etc.), contaminated subsoils, and structures and equipment contaminated with waste and leachate and manage them as h…
Chapter 43. Interim Status-4707 Applicability
0.5K chars
A. The requirements of this Subchapter apply to owners or operators who store munitions and explosive hazardous wastes, except as LAC 33:V.4301 provides otherwise. [NOTE: Depending on explosive hazards, hazardous waste munitions and explosives may also be managed in other types o…
Chapter 43. Interim Status-4709 Design and Operating Standards
3.4K chars
A. Hazardous waste munitions and explosives storage units must be designed and operated with containment systems, controls, and monitoring that: 1. minimize the potential for detonation or other means of release of hazardous waste, hazardous constituents, hazardous decomposition …
Chapter 43. Interim Status-4711 Closure and Post-Closure Care
1.2K chars
A. At closure of a magazine or unit that stored hazardous waste under this Subchapter, the owner or operator must remove or decontaminate all waste residues, contaminated containment system components, contaminated subsoils, and structures and equipment contaminated with waste an…
Chapter 43. Interim Status-4719 Applicability
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1747.
Chapter 43. Interim Status-4721 Definitions
0.1K chars
A. As used in this Subchapter, all terms shall have the meanings given to them in LAC 33:V.1703.
Chapter 43. Interim Status-4723 Schedule for Implementation of Air Emission Standards
4.8K chars
A. Owners or operators of facilities existing on December 6, 1996, and subject to Subchapters H, I, and J of this Chapter shall meet the following requirements. 1. Install and begin operation of control equipment or waste management units required to comply with this Subchapter a…
Chapter 43. Interim Status-4725 Standards: General
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1751.
Chapter 43. Interim Status-4727 Waste Determination Procedures
34.8K chars
A. Waste Determination Procedures to Determine Average Volatile Organic (VO) Concentration of a Hazardous Waste at the Point of Waste Origination 1. An owner or operator shall determine the average VO concentration at the point of waste origination for each hazardous waste placed…
Chapter 43. Interim Status-4729 Standards: Tanks
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1755.
Chapter 43. Interim Status-4731 Standards: Surface Impoundments
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1757.
Chapter 43. Interim Status-4733 Standards: Containers
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1759.
Chapter 43. Interim Status-4735 Standards: Closed-Vent Systems and Control Devices
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1761.
Chapter 43. Interim Status-4737 Inspection and Monitoring Requirements
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1763.
Chapter 43. Interim Status-4739 Recordkeeping Requirements
0.1K chars
A. Interim status facilities are subject to the requirements of LAC 33:V.1765.