R.255.463 § 255.463 External corrosion control: cathodic protection.
0.9K chars
(a) Each cathodic protection system required by this Part must provide a level of cathodic protection that complies with one or more of the applicable criteria contained in Appendix 14-D of this Title. If none of these criteria are applicable, the cathodic protection system must …
R.255.465 § 255.465 External corrosion control: monitoring.
2.7K chars
(a) Pipe-to-soil electrical potential tests or other acceptable electrical tests shall be conducted over each pipeline 100 feet (30.5 meters), or longer that is under cathodic protection at least once each calendar year, but with intervals not exceeding 15 months, to determine wh…
R.255.467 § 255.467 External corrosion control: electrical isolation.
2.6K chars
(a) Each buried or submerged pipeline must be electrically isolated from other underground metallic structures, unless the pipeline and the other structures are electrically interconnected and cathodically protected as a single unit. (b) One or more insulating devices must be ins…