R.255.181 § 255.181 Distribution line valves.
1.7K chars
(a) Each high pressure distribution system must have valves spaced so as to reduce the time to shut down a section of main in an emergency. The valve spacing is determined by the operating pressure, the size of the mains, and the local physical conditions as well as the number an…
R.255.183 § 255.183 Vaults: structural design requirements.
1.6K chars
(a) Each underground vault or pit for valves, pressure relieving, pressure limiting, or pressure regulating equipment, must be able to meet the loads which may be imposed upon it, and to protect installed equipment. (b) There must be enough working space so that all of the equipm…
R.255.185 § 255.185 Vaults: accessibility.
0.3K chars
Each vault must be located in an accessible location and, so far as practical, away from: (a) street intersections or points where traffic is heavy or dense; (b) points of minimum elevation, catch basins, or places where the access cover will be in the course of surface waters; a…