213 sections in this chapter.
33.1-24-02-N.D. Admin. Code § 33.1-24-02-182 Standards - Pumps in light liquid service
5.2K chars
1. Timeframe. a. Each pump in light liquid service must be monitored monthly to detect leaks by the methods specified in subsection 2 of section 33.1-24-02-193, except as provided in subsections 4, 5, and 6. b. Each pump in light liquid service must be checked by visual inspectio…
33.1-24-02-N.D. Admin. Code § 33.1-24-02-183 Standards - Compressors
3.7K chars
1. Each compressor must be equipped with a seal system that includes a barrier fluid system and which prevents leakage of total organic emissions to the atmosphere, except as provided in subsections 8 and 9. 2. Each compressor seal system as required in subsection 1 must be: a. O…
33.1-24-02-N.D. Admin. Code § 33.1-24-02-184 Standards - Pressure relief devices in gas or vapor service
1.6K chars
1. Except during pressure releases, each pressure relief device in gas or vapor service must be operated with no detectable emissions, as indicated by an instrument reading of less than five hundred parts per million above background, as measured by the method specified in subsec…