1,156 sections in this chapter.
33.1-24-05-N.D. Admin. Code § 33.1-24-05-118 Applicability of surface impoundment requirements
0.4K chars
Sections 33.1-24-05-118 through 33.1-24-05-129 apply to owners and operators of facilities that use surface impoundments to treat, store, or dispose of hazardous waste, except as section 33.1-24-05-01 provides otherwise. History: Effective January 1, 2019. General Authority: NDCC…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-119 Design and operating requirements
0.8K chars
1. Any surface impoundment that is not covered by subsection 3 must have a liner for all portions of the impoundment (except for existing portions of such impoundments). The liner 166 must be designed, constructed, and installed to prevent any migration of wastes out of the impou…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-12 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-120 Monitoring and inspection
4.1K chars
1. During construction and installation, liners (except in the case of existing portions of surface impoundments exempt from subsection 1 of section 33.1-24-05-119) and cover systems (for example, membranes, sheets, or coatings) must be inspected for uniformity, damage, and imper…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-121 Emergency repairs - Contingency plans
7.1K chars
1. A surface impoundment must be removed from service in accordance with subsection 2 when: a. The level of liquids in the impoundment suddenly drops and the drop is not known to be caused by changes in the flows into or out of the impoundment; or b. The dike leaks. 2. When a sur…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-122 For impoundments that will be closed in accordance with subdivision b of
11.4K chars
subsection 1 of section 33.1-24-05-122, the liner must be constructed of materials that can prevent wastes from migrating into the liner during the active life of the facility. The liner must be: a. Constructed of materials that have appropriate chemical properties and sufficient…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-123 Special requirements for ignitable or reactive waste
1.0K chars
Ignitable or reactive waste may not be placed in a surface impoundment, unless the waste and impoundment satisfy all applicable requirements of sections 33.1-24-05-250 through 33.1-24-05-299; and: 1. The waste is treated, rendered, or mixed before or immediately after placement i…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-124 Special requirements for incompatible wastes
0.4K chars
Incompatible wastes, or incompatible wastes and materials (see appendix III for examples of incompatible wastes and materials), may not be placed in the same surface impoundment, unless the owner or operator complies with subsection 2 of section 33.1-24-05-08. History: Effective …
33.1-24-05-N.D. Admin. Code § 33.1-24-05-126 Action leakage rate
2.0K chars
1. The department shall approve an action leakage rate for surface impoundment units subject to subsection 3 or 4 of section 33.1-24-05-119. The action leakage rate is the maximum design flow rate that the leak detection system can remove without the fluid head on the bottom line…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-128 Air emission standards
0.3K chars
The owner or operator shall manage all hazardous waste placed in a surface impoundment in accordance with the requirements of sections 33.1-24-05-420 through 33.1-24-05-474. History: Effective January 1, 2019. General Authority: NDCC 23.1-04-03; S.L. 2017, ch. 199, § 1 Law Implem…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-129 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-13 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-130 Applicability of waste pile requirements
1.4K chars
1. Sections 33.1-24-05-130 through 33.1-24-05-143 apply to owners or operators of facilities that store or treat hazardous waste in piles, except as section 33.1-24-05-01 provides otherwise. 2. Sections 33.1-24-05-130 through 33.1-24-05-143 do not apply to owners and operators of…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-132 Monitoring and inspection
1.8K chars
1. During construction or installation, liners (except in the case of existing portions of piles exempt from subsection 1 of section 33.1-24-05-131) and cover systems (for example, membranes, sheets, or coatings) must be inspected for uniformity, damage, and imperfections, for ex…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-133 Special requirements for ignitable or reactive wastes
0.9K chars
Ignitable or reactive waste may not be placed in a waste pile unless the waste or waste pile satisfies all applicable requirements of sections 33.1-24-05-250 through 33.1-24-05-299. 1. The waste is treated, rendered, or mixed before or immediately after placement in the pile so t…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-134 Special requirements for incompatible wastes
0.9K chars
1. Incompatible wastes, or incompatible wastes and materials, may not be placed in the same pile unless subsection 2 of section 33.1-24-05-08 is complied with. 2. A pile of hazardous waste that is incompatible with any waste or other material stored nearby in containers, other pi…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-135 Closure and postclosure care
2.3K chars
1. At closure, the owner or operator must remove or decontaminate all waste residue, contaminated containment system components (liners, etc.), contaminated subsoils, and structures and equipment contaminated with waste and leachate, and manage them as hazardous waste unless subs…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-136 Special requirements for hazardous wastes F020, F021, F022, F023, F026,
1.8K chars
and F027. 1. Hazardous wastes F020, F021, F022, F023, F026, and F027 must not be placed in waste piles that are not enclosed (as defined in subsection 3 of section 33.1-24-05-130) unless the owner or operator operates the waste pile in accordance with a management plan for these …
33.1-24-05-N.D. Admin. Code § 33.1-24-05-137 Action leakage rate
1.7K chars
1. The department shall approve an action leakage rate for waste pile units subject to subsection 2 or 3 of section 33.1-24-05-131. The action leakage rate is the maximum design flow rate that the leak detection system can remove without the fluid head on the bottom liner exceedi…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-138 Response actions
3.0K chars
1. The owner or operator of waste pile units subject to subsection 2 or 3 of section 33.1-24-05-131 must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-139 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-14 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-140 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-141 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-142 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-143 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-144 Applicability of incinerator requirements
5.1K chars
1. Sections 33.1-24-05-144 through 33.1-24-05-159 apply to owners or operators of hazardous waste incinerators, except as section 33.1-24-05-01 provides otherwise. 2. Integration of the maximum achievable control technology standards. a. Except as provided by subdivisions b throu…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-145 Waste analysis
1.0K chars
1. As a portion of the trial burn plan or with the permit application, the owner or operator shall have included an analysis of the waste feed sufficient to provide all information required by subdivision b of subsection 2 of section 33.1-24-06-19 or subdivision w of subsection 2…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-146 Designation of principal organic hazardous constituents
1.6K chars
1. Principal organic hazardous constituents in the waste feed must be treated to the extent required by the performance standard specified in section 33.1-24-05-147. 2. Designation of principal organic hazardous constituents. a. For each waste feed to be burned, one or more princ…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-147 Performance standards
3.9K chars
An incinerator burning hazardous waste must be designed, constructed, and maintained so that when operated in accordance with operating requirements specified under section 33.1-24-05-149 it will meet the following performance standards: 185 1. a. Except as provided in subdivisio…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-148 Hazardous waste incinerator permits
3.4K chars
1. The owner or operator of a hazardous waste incinerator may burn only waste specified in the permit and only under operating conditions specified for those wastes under section 33.1-24-05-149, except: a. In approved trial burns under subsection 2 of section 33.1-24-06-19; or b.…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-149 Operating requirements
2.8K chars
1. An incinerator must be operated in accordance with operating requirements specified in the permit. These will be specified on a case-by-case basis as those demonstrated (in a trial burn or in alternative data as specified in subsection 2 of section 33.1-24-05-148 and included …
33.1-24-05-N.D. Admin. Code § 33.1-24-05-15 Design and operation of facility
0.5K chars
Facilities must be designed, constructed, maintained, and operated to minimize the possibility of a fire, explosion, or any unplanned sudden or nonsudden release of hazardous waste or hazardous waste constituents to air, soil, or surface water which could threaten human health or…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-150 Monitoring and inspections
1.7K chars
1. The owner or operator shall conduct, at a minimum, the following monitoring while incinerating hazardous waste: a. Combustion temperature, waste feed rate, and the indicator of combustion gas velocity specified in the permit must be monitored on a continuous basis; b. Carbon m…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-151 Closure
0.3K chars
At closure the owner or operator shall remove all hazardous waste and hazardous waste residues (including ash, scrubber waters, and scrubber sludges) from the incinerator site. History: Effective January 1, 2019. General Authority: NDCC 23.1-04-03; S.L. 2017, ch. 199, § 1 Law Imp…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-152 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-153 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-154 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-155 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-156 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-157 [Reserved]
0.0K chars
189
33.1-24-05-N.D. Admin. Code § 33.1-24-05-158 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-159 [Reserved]
2835.5K chars
CHAPTER 33.1-24-05 STANDARDS FOR TREATMENT, STORAGE, AND DISPOSAL FACILITIES AND FOR THE MANAGEMENT OF SPECIFIC HAZARDOUS WASTES AND SPECIFIC TYPES OF HAZARDOUS WASTE MANAGEMENT FACILITIES Section 33.1-24-05-01 Purpose, Scope, and Applicability 33.1-24-05-02 Identification Number…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-16 Required equipment
1.3K chars
All facilities must be equipped with the following, unless it can be demonstrated to the department that none of the hazards posed by waste handled at the facility could require a particular kind of equipment specified below: 38 1. An internal communications or alarm system capab…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-160 Applicability of land treatment requirements
0.4K chars
Sections 33.1-24-05-160 through 33.1-24-05-175 apply to owners and operators of facilities that treat or dispose of hazardous waste in land treatment units, except as section 33.1-24-05-01 provides otherwise. History: Effective January 1, 2019. General Authority: NDCC 23.1-04-03;…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-162 Treatment demonstration
2.8K chars
1. For each waste that will be applied to the treatment zone, the owner or operator shall demonstrate prior to application of the waste that hazardous constituents in the waste can be completely degraded, transformed, or immobilized in the treatment zone. 2. In making this demons…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-163 Design and operating requirements
2.6K chars
The department will specify in the facility permit how the owner or operator will design, construct, operate, and maintain the land treatment unit in compliance with this section. 191 1. The owner or operator shall design, construct, and maintain the unit to maximize the degradat…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-164 Food chain crops
5.6K chars
The department may allow the growth of food chain crops in or on the treatment zone only if the owner or operator satisfies the conditions of this section. The department will specify in the facility permit the specific food chain crops which may be grown. 1. The owner or operato…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-165 Unsaturated zone monitoring
8.9K chars
An owner or operator subject to sections 33.1-24-05-160 through 33.1-24-05-175 shall establish an unsaturated zone monitoring program to discharge the following responsibilities: 1. The owner or operator shall monitor the soil and soil-pore liquid to determine whether hazardous c…
33.1-24-05-N.D. Admin. Code § 33.1-24-05-166 Recordkeeping
0.3K chars
The owner or operator shall include hazardous waste application dates and rates in the operating record required under section 33.1-24-05-40. History: Effective January 1, 2019. General Authority: NDCC 23.1-04-03; S.L. 2017, ch. 199, § 1 Law Implemented: NDCC 23.1-04-03, 23.1-04-…