40,722 sections across 3,069 Oregon regulatory chapters.
R.333-102-333-102-0345 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Special Procedures in Regulatory Review
2.9K chars
333-102-0345 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Special Procedures in Regulatory Review (1) The provisions of ORS Chapter 183 governing contested cases are …
R.333-102-333-102-0350 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Reporting Requirements
5.0K chars
333-102-0350 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Reporting Requirements (1) Immediate report. Each licensee must notify the Authority as soon as possible but…
R.333-102-333-102-0355 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Records
4.7K chars
333-102-0355 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Records (1) Each person who receives radioactive material pursuant to a license issued in accordance with th…
R.333-102-333-102-0360 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Right to Cause the Withholding or Recall of Byproduct Material
0.9K chars
333-102-0360 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Right to Cause the Withholding or Recall of Byproduct Material The Authority may cause the withholding or re…
R.333-102-333-102-0365 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Third Party Method
2.2K chars
333-102-0365 Special Requirement for a Specific License to Manufacture, Assemble, Repair or Distribute Commodities, Products or Devices Which Contain Radioactive Material: Third Party Method If the applicant consents, the Authority may enter into third party agreements for the ap…
R.333-102-333-102-0900 Transport: Special Requirements for Specific Licenses of Broad Scope
8.5K chars
333-102-0900 Transport: Special Requirements for Specific Licenses of Broad Scope This rule prescribes requirements for the issuance of specific licenses of broad scope for radioactive material and certain rules governing holders of such licenses. (1) The different types of broad…
R.333-102-333-102-0910 Transport: Specific Terms and Conditions for Broad Licenses
1.0K chars
333-102-0910 Transport: Specific Terms and Conditions for Broad Licenses (1) No licensee may use radioactive material in or on human beings or in field applications where radioactive material is released except as specifically authorized by license. (2) Experimental animals admin…
R.333-103-333-103-0001 Purpose and Scope
1.5K chars
333-103-0001 Purpose and Scope (1) The rules in this division establish fees for sources of radiation and provide for their payment. Sources of radiation, as defined in OAR 333-100-0005, include, but are not limited to, radiation facilities, radiation machine tubes, radiation pro…
R.333-103-333-103-0003 Definitions
2.4K chars
333-103-0003 Definitions As used in this division, the following definitions apply: (1) "Dental, academic or veterinary X-ray machine tube" means any X-ray machine tube designed and manufactured for dental diagnostics, research, and development, or used for the healing arts of an…
R.333-103-333-103-0005 Biennial Fee for Radiation Machine Tubes
2.0K chars
333-103-0005 Biennial Fee for Radiation Machine Tubes (1) For the purpose of this division, a radiation machine is defined under OAR 333-100-0005. (2) Each radiation machine tube shall be validated biennially by a radiation machine tube fee in the following amounts: (a) Hospital,…
R.333-103-333-103-0010 Annual Fee for Specific Licenses
4.8K chars
333-103-0010 Annual Fee for Specific Licenses (1)(a) Each specific license listed in section (2) of this rule, as defined in OAR 333-102-0203, shall be licensed pursuant to sections (2), (3), (4), (5) and (6) of this rule by a specific license fee. (b) Upon written request and ap…
R.333-103-333-103-0015 Annual Registration Fee for General Licenses and Devices
3.7K chars
333-103-0015 Annual Registration Fee for General Licenses and Devices (1) Any general license granted by the Authority must be validated annually by the general license registration fee listed in section (2) of this rule, unless otherwise exempted by subsection (2)(e) of this rul…
R.333-103-333-103-0020 Biennial Fee for Microwave Oven Service Licensees
1.3K chars
333-103-0020 Biennial Fee for Microwave Oven Service Licensees (1) Each license issued by the Authority for microwave oven service shall be subject to a biennial $140 specific license fee. (2) The license fee shall be due and payable on or before October 1 of each biennium. (3) A…
R.333-103-333-103-0025 Annual Fee for Tanning Devices
1.2K chars
333-103-0025 Annual Fee for Tanning Devices (1) Each tanning device must be validated annually by a tanning device fee of $175. (2) The tanning device fee shall be due and payable for each tanning device on or before March 1 of each year. (3) A certificate of validation or acknow…
R.333-103-333-103-0030 Reciprocal Recognition Fee
1.4K chars
333-103-0030 Reciprocal Recognition Fee (1) Any radiation machine or radioactive material source brought into the state for use under reciprocity must pay a fee equal to 100 percent of the appropriate license or registration validation fee, listed in OAR 333-103-0005 or 333-103-0…
R.333-103-333-103-0035 Fees For Radiological Analyses
1.7K chars
333-103-0035 Fees For Radiological Analyses (1) An individual, agency, or company that requests that the Authority’s Radiation Laboratory perform radiological analyses on samples must pay a fee to the Authority in accordance with the schedule in section (2) of this rule. The resp…
R.333-103-333-103-0050 Fees for Accredited Hospital Radiology Inspectors
0.6K chars
333-103-0050 Fees for Accredited Hospital Radiology Inspectors (1) Each accreditation for a radiology inspector shall be subject to an accreditation fee of $264. (2) Each accreditation issued by the Authority for a radiology inspector shall be subject to a biennial renewal fee of…
R.333-103-333-103-0055 X-ray and Tanning Machine Vendor License Fee
1.0K chars
333-103-0055 X-ray and Tanning Machine Vendor License Fee (1) Persons shall obtain a vendor license for radiation machine and tanning services pursuant to OAR 333-101-0020 and 333-119-0200 and shall pay an annual validation fee of $500 to obtain or maintain the license. (2) Upon …
R.333-105-333-105-0001 Purpose
0.5K chars
333-105-0001 Purpose This division prescribes requirements for the industrial use of sources of radiation and radiation safety requirements for persons using these sources of radiation in industrial radiography. Statutory/Other Authority: ORS 453.635 Statutes/Other Implemented: O…
R.333-105-333-105-0003 Scope
0.8K chars
333-105-0003 Scope The provisions and requirements of this division are in addition to, and not in substitution for, other requirements of these rules. In particular, the general requirements of divisions 100, 102, 111, 118, and 120 of this chapter apply to applicants and license…
R.333-105-333-105-0005 Definitions
10.1K chars
333-105-0005 Definitions As used in this division, the following definitions apply: (1) "Annual refresher safety training" means a review conducted or provided by the licensee for its employees on radiation safety aspects of industrial radiography. The review must include, as a m…
R.333-105-333-105-0050 Exemptions
0.7K chars
333-105-0050 Exemptions Industrial uses of lixiscopes are exempt from the requirements of this division if the dose rate 18 inches from the source of radiation to any individual does not exceed two millirem per hour. Devices that exceed this limit must meet the applicable require…
R.333-105-333-105-0075 Licensing and Registration Requirements for Industrial Radiography Operations
4.1K chars
333-105-0075 Licensing and Registration Requirements for Industrial Radiography Operations The Authority will approve an application for a specific license for the use of licensed material if the applicant meets the following requirements: (1) The applicant satisfies the general …
R.333-105-333-105-0420 Equipment Control: Performance Requirements for Industrial Radiography Equipment
4.9K chars
333-105-0420 Equipment Control: Performance Requirements for Industrial Radiography Equipment Equipment used in industrial radiographic operations must meet the following minimum criteria: (1) Each radiographic exposure device, source assembly or sealed source, and all associated…
R.333-105-333-105-0430 Equipment Control: Limits on External Radiation Levels From Storage Containers and Source Changers
0.6K chars
333-105-0430 Equipment Control: Limits on External Radiation Levels From Storage Containers and Source Changers The maximum exposure rate limits for storage containers and source changers are two millisieverts (200 mrem) per hour at any exterior surface, and 0.1 millisieverts (10…
R.333-105-333-105-0440 Equipment Control: Locking of Sources of Radiation, Storage Containers and Source Changers
1.8K chars
333-105-0440 Equipment Control: Locking of Sources of Radiation, Storage Containers and Source Changers (1) Each radiographic exposure device must have a lock or outer locked container designed to prevent unauthorized or accidental removal of the sealed source from its shielded p…
R.333-105-333-105-0450 Equipment Control: Radiation Survey Instruments
1.6K chars
333-105-0450 Equipment Control: Radiation Survey Instruments (1) The licensee must keep sufficient calibrated and operable radiation survey instruments at each location where sources of radiation are present to make the radiation surveys required by this division and by division …
R.333-105-333-105-0460 Equipment Control: Leak Testing and Replacement of Sealed Sources
3.9K chars
333-105-0460 Equipment Control: Leak Testing and Replacement of Sealed Sources (1) The replacement of any sealed source fastened to or contained in a radiographic exposure device and leak testing of any sealed source must be performed by persons authorized to do so by the Authori…
R.333-105-333-105-0470 Equipment Control: Quarterly Inventory
0.6K chars
333-105-0470 Equipment Control: Quarterly Inventory (1) Each licensee must conduct a quarterly physical inventory to account for all sources of radiation, and for devices containing depleted uranium received and possessed under the license. (2) The licensee must maintain records …
R.333-105-333-105-0480 Equipment Control: Inspection and Maintenance of Radiation Machines, Radiographic Exposure Devices, Transport and Storage Containers, Associated Equipment, Source Changers, and Survey Instruments
1.9K chars
333-105-0480 Equipment Control: Inspection and Maintenance of Radiation Machines, Radiographic Exposure Devices, Transport and Storage Containers, Associated Equipment, Source Changers, and Survey Instruments (1) The licensee must perform visual and operability checks on survey m…
R.333-105-333-105-0490 Equipment Control: Permanent Radiographic Installations
1.8K chars
333-105-0490 Equipment Control: Permanent Radiographic Installations (1) Each entrance that is used for personnel access to the high radiation area in a permanent radiographic installation must have either: (a) An entrance control of the type described in OAR 333-120-0220 that ca…
R.333-105-333-105-0500 Equipment Control: Labeling, Storage, and Transportation
1.8K chars
333-105-0500 Equipment Control: Labeling, Storage, and Transportation (1) The licensee may not use a source changer or a container to store radioactive material unless the source changer or the storage container has securely attached to it a durable, legible, and clearly visible …
R.333-105-333-105-0510 Radiation Safety Requirements: Conducting Industrial Radiographic Operations
1.4K chars
333-105-0510 Radiation Safety Requirements: Conducting Industrial Radiographic Operations (1) Whenever radiography is performed at a location other than a permanent radiographic installation, the radiographer must be accompanied by at least one other qualified radiographer or an …
R.333-105-333-105-0520 Radiation Safety Requirements: Radiation Safety Officer
2.5K chars
333-105-0520 Radiation Safety Requirements: Radiation Safety Officer The radiation safety officer must ensure that radiation safety activities are being performed in accordance with approved procedures and regulatory requirements in the daily operation of the licensee's program. …
R.333-105-333-105-0530 Radiation Safety Requirements: Training
7.4K chars
333-105-0530 Radiation Safety Requirements: Training (1) The licensee may not permit any individual to act as a radiographer until the individual: (a) Has received training in the subjects outlined in section (7) of this rule, in addition to on the job training consisting of hand…
R.333-105-333-105-0540 Radiation Safety Requirements: Operating and Emergency Procedures
2.2K chars
333-105-0540 Radiation Safety Requirements: Operating and Emergency Procedures (1) Operating and emergency procedures must include, as a minimum, instructions in the following: (a) Appropriate handling and use of sources of radiation so that no person is likely to be exposed to r…
R.333-105-333-105-0550 Radiation Safety Requirements: Supervision of Radiographer's Assistants
1.1K chars
333-105-0550 Radiation Safety Requirements: Supervision of Radiographer's Assistants The radiographer's assistant must be under the direct visual supervision of a radiographer when using radiographic exposure devices, associated equipment or sources of radiation, or when conducti…
R.333-105-333-105-0560 Radiation Safety Requirements: Personnel Monitoring
4.0K chars
333-105-0560 Radiation Safety Requirements: Personnel Monitoring (1) The licensee may not permit any individual to act as a radiographer or a radiographer's assistant unless, at all times during radiographic operations, each individual wears, on the trunk of the body, a combinati…
R.333-105-333-105-0570 Radiation Safety Requirements: Radiation Surveys
1.2K chars
333-105-0570 Radiation Safety Requirements: Radiation Surveys The licensee must: (1) Conduct all surveys with a calibrated and operable radiation survey instrument that meets the requirements of 333-105-0450; (2) Conduct a survey of the radiographic exposure device and the guide …
R.333-105-333-105-0580 Radiation Safety Requirements: Surveillance
0.7K chars
333-105-0580 Radiation Safety Requirements: Surveillance During each radiographic operation, the radiographer must ensure continuous direct visual surveillance of the operation to protect against unauthorized entry into a radiation area or a high radiation area, as defined in div…
R.333-105-333-105-0590 Radiation Safety Requirements: Posting
0.5K chars
333-105-0590 Radiation Safety Requirements: Posting All areas in which industrial radiography is being performed must be conspicuously posted as required by OAR 333-120-0410. The exceptions listed in 333-120-0420 do not apply to industrial radiographic operations. Statutory/Other…
R.333-105-333-105-0600 Recordkeeping Requirements: Records for Industrial Radiography
0.6K chars
333-105-0600 Recordkeeping Requirements: Records for Industrial Radiography Each licensee must maintain a copy of its license, documents incorporated by reference, and amendments to each of these items until superseded by new documents approved by the Authority, or until the Auth…
R.333-105-333-105-0610 Recordkeeping Requirements: Records of Receipt and Transfer of Sources of Radiation
0.9K chars
333-105-0610 Recordkeeping Requirements: Records of Receipt and Transfer of Sources of Radiation (1) Each licensee must maintain records showing the receipts and transfers of sealed sources, devices using Depleted Uranium (DU) for shielding, and radiation machines, and retain eac…
R.333-105-333-105-0620 Records of Radiation Survey Instruments
0.5K chars
333-105-0620 Records of Radiation Survey Instruments Each licensee must maintain records of the calibrations of its radiation survey instruments that are required under 333-105-0450 and retain each record for three years after it is made. Statutory/Other Authority: ORS 453.635 St…
R.333-105-333-105-0630 Recordkeeping Requirements: Records of Leak Testing of Sealed Sources and Devices Containing DU
0.7K chars
333-105-0630 Recordkeeping Requirements: Records of Leak Testing of Sealed Sources and Devices Containing DU Each licensee must maintain records of leak test results for sealed sources and for devices containing DU. The results must be stated in units of Becquerels (microcuries).…
R.333-105-333-105-0640 Recordkeeping Requirements: Records of Quarterly Inventory
0.9K chars
333-105-0640 Recordkeeping Requirements: Records of Quarterly Inventory (1) Each licensee must maintain records of the quarterly inventory of sources of radiation, including devices containing DU as required by 333-105-0470, and retain each record for three years. (2) The record …
R.333-105-333-105-0650 Recordkeeping Requirements: Utilization Logs
1.0K chars
333-105-0650 Recordkeeping Requirements: Utilization Logs (1) Each licensee must maintain utilization logs showing for each source of radiation the following information: (a) A description, including the make, model, and serial number of the radiation machine or the radiographic …
R.333-105-333-105-0660 Recordkeeping Requirements: Records of Inspection and Maintenance of Radiation Machines, Radiographic Exposure Devices, Transport and Storage Containers, Associated Equipment, Source Changers, and Survey Instruments
1.0K chars
333-105-0660 Recordkeeping Requirements: Records of Inspection and Maintenance of Radiation Machines, Radiographic Exposure Devices, Transport and Storage Containers, Associated Equipment, Source Changers, and Survey Instruments (1) Each licensee must maintain records specified i…
R.333-105-333-105-0670 Recordkeeping Requirements: Records of Alarm System and Entrance Control Checks at Permanent Radiographic Installations
0.6K chars
333-105-0670 Recordkeeping Requirements: Records of Alarm System and Entrance Control Checks at Permanent Radiographic Installations Each licensee must maintain records of alarm system and entrance control device tests required by 333-105-0490 and retain each record for three yea…
R.333-105-333-105-0680 Recordkeeping Requirements: Records Of Training and Certification
1.4K chars
333-105-0680 Recordkeeping Requirements: Records Of Training and Certification Each licensee must maintain the following records for three years after the individual terminates employment: (1) Records of training of each radiographer and each radiographer's assistant. The record …