6,477 sections across 106 South Carolina regulatory chapters.
R.8-1204 IRC Figure R302.1 Exterior walls
1.8K chars
8-1204. IRC Figure R302.1 Exterior walls. Exception 6: Fire Separation Distance a. The minimum fire separation distance for improvement constructed on a lot shown on: [i] a recorded bonded or final subdivision plat, or [ii] a sketch plan, site plan, plan of phased develop- ment o…
R.8-1205 IRC Section R302.4.1 Through penetrations
1.5K chars
8-1205. IRC Section R302.4.1 Through penetrations. Through penetrations of fire-resistance-rated wall or floor assemblies shall comply with Section 302.4.1.1 or R302.4.1.2. No penetrations shall pass completely through the fire rated assembly separating townhouse units. Exception…
R.8-1206 IRC Section R302.5.1 Opening protection
0.4K chars
8-1206. IRC Section R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in th…