R.246-215-246-215-04258 Functionality—Warewashing machines, automatic dispensing of detergents and sanitizers (FDA Food Code 4-204.117).
0.6K chars
A warewashing machine that is installed after adoption of this chapter by the regulatory authority must be equipped to:(1) Automatically dispense detergents and sanitizers; and (2) Incorporate a visual means to verify that detergents and sanitizers are delivered or a visual or au…
R.246-215-246-215-04260 Functionality—Warewashing machines, flow pressure device (FDA Food Code 4-204.118).
0.8K chars
(1) warewashing machines that provide a fresh hot water sanitizing rinse must be equipped with a pressure gauge or similar device such as a transducer that measures and displays the water pressure in the supply line immediately before entering the warewashing machine; and(2) If t…
R.246-215-246-215-04262 Functionality—Warewashing sinks and drainboards, self-draining (FDA Food Code 4-204.119).
0.3K chars
Sinks and drainboards of warewashing sinks and machines must be self-draining.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04262, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04262, filed 1/17/13, effective 5/1/13.]
R.246-215-246-215-04264 Functionality—Equipment compartments, drainage (FDA Food Code 4-204.120).
0.4K chars
equipment compartments that are subject to accumulation of moisture due to conditions such as condensation, food or beverage drip, or water from melting ice must be sloped to an outlet that allows complete draining.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122,…
R.246-215-246-215-04266 Functionality—Vending machines, liquid waste products (FDA Food Code 4-204.121).
1.0K chars
(1) vending machines designed to store beverages that are packaged in containers made from paper products must be equipped with diversion devices and retention pans or drains for container leakage.(2) vending machines that dispense liquid food in bulk must be:(a) Provided with an…
R.246-215-246-215-04268 Functionality—Case lot handling equipment, moveability (FDA Food Code 4-204.122).
0.5K chars
Apparatuses, such as dollies, pallets, racks, and skids used to store and transport large quantities of packaged foods received from a supplier in a cased or overwrapped lot, must be designed to be moved by hand or by conveniently available apparatuses such as hand trucks and for…
R.246-215-246-215-04270 Functionality—Vending machine doors and openings (FDA Food Code 4-204.123).
1.1K chars
(1) vending machine doors and access opening covers to food and container storage spaces must be tight-fitting so that the space along the entire interface between the doors or covers and the cabinet of the machine, if the doors or covers are in a closed position, is no greater t…
R.246-215-246-215-04272 Acceptability—Food equipment, certification and classification (FDA Food Code 4-205.10).
0.4K chars
food equipment that is certified or classified for sanitation in conformance with a recognized American National Standards Institute (ANSI) - Accredited certification program is deemed to comply with Subparts A and B of this part.[Statutory Authority: RCW 43.20.050 and 43.20.145.…
R.246-215-246-215-04300 Equipment—Cooling, heating, and holding capacities (FDA Food Code 4-301.11).
0.3K chars
equipment for cooling and heating food, and holding cold and hot food, must be sufficient in number and capacity to provide food temperatures as specified under Part 3.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04300, filed 12/15/20, effective 3/1…
R.246-215-246-215-04305 Equipment—Manual warewashing, sink compartment requirements (FDA Food Code 4-301.12).
2.0K chars
(1) Except as specified in subsection (3) of this section, a sink with at least three compartments must be provided for manually washing, rinsing, and sanitizing equipment and utensils. (2) Sink compartments must be large enough to accommodate immersion of the largest equipment a…
R.246-215-246-215-04310 Equipment—Drainboards (FDA Food Code 4-301.13).
0.4K chars
Drainboards, utensil racks, or tables large enough to accommodate all soiled and cleaned items that might accumulate during hours of operation must be provided for necessary utensils holding before cleaning and after sanitizing.[Statutory Authority: RCW 43.20.050 and 43.20.145. W…
R.246-215-246-215-04315 Equipment—Ventilation hood systems, adequacy (FDA Food Code 4-301.14).
0.3K chars
Ventilation hood systems and devices must be sufficient in number and capacity to prevent grease or condensation from collecting on walls and ceilings.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04315, filed 12/15/20, effective 3/1/22; WSR 13-03-10…
R.246-215-246-215-04320 Equipment—Clothes washers and dryers (FDA Food Code 4-301.15).
0.6K chars
(1) Except as specified in subsection (2) of this section, if work clothes or linens are laundered on the premises, a mechanical clothes washer and dryer must be provided and used.(2) If on-premises laundering is limited to wiping cloths intended to be used moist, or wiping cloth…
R.246-215-246-215-04325 Equipment—Designated food preparation sinks.
0.5K chars
food establishments must have designated food preparation sinks that are:(1) Sufficient in number and size to wash, soak, rinse, drain, cool, thaw, or otherwise process any food that requires placement in a sink;(2) Appropriate for the menu, method of food preparation, and volume…
R.246-215-246-215-04330 Utensils, temperature measuring devices, and testing devices—Utensils, consumer self-service (FDA Food Code 4-302.11).
0.3K chars
A food dispensing utensil must be available for each container displayed at a consumer self-service unit such as a buffet or salad bar.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04330, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-043…
R.246-215-246-215-04335 Utensils, temperature measuring devices, and testing devices—Food temperature measuring devices (FDA Food Code 4-302.12).
0.6K chars
(1) food temperature measuring devices must be provided and readily accessible for use in ensuring attainment and maintenance of food temperatures as specified under Part 3.(2) A temperature measuring device with a suitable small-diameter probe that is designed to measure the tem…
R.246-215-246-215-04340 Utensils, temperature measuring devices, and testing devices—Temperature measuring devices, manual warewashing (FDA Food Code 4-302.13).
0.5K chars
(1) In manual warewashing operations, a temperature measuring device must be provided and readily accessible for frequently measuring the washing and sanitizing temperatures.(2) In hot water mechanical warewashing operations, an irreversible registering temperature indicator must…
R.246-215-246-215-04345 Utensils, temperature measuring devices, and testing devices—Sanitizing solutions, testing devices (FDA Food Code 4-302.14).
0.3K chars
A test kit or other device that accurately measures the concentration in mg/L of sanitizing solutions must be provided.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04345, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04345, filed 1/17/1…
R.246-215-246-215-04350 Cleaning agents and sanitizers—Cleaning agents and sanitizers availability (FDA Food Code 4-303.11).
0.6K chars
(1) Cleaning agents that are used to clean equipment and utensils as specified under Part 4, Subpart F of this chapter, must be provided and available for use during all hours of operation.(2) Except for those that are generated on-site at the time of use, chemical sanitizers tha…
R.246-215-246-215-04400 Location—Equipment, clothes washers and dryers, and storage cabinets, contamination prevention (FDA Food Code 4-401.11).
1.2K chars
(1) Except as specified in subsection (2) of this section, equipment, a cabinet used for the storage of food, or a cabinet that is used to store cleaned and sanitized equipment, utensils, laundered linens, and single-service and single-use articles may not be located:(a) In locke…
R.246-215-246-215-04405 Installation—Fixed equipment, spacing or sealing (FDA Food Code 4-402.11).
0.8K chars
(1) equipment that is fixed because it is not easily movable must be installed so that it is:(a) Spaced to allow access for cleaning along the sides, behind, and above the equipment;(b) Spaced from adjoining equipment, walls, and ceilings a distance of not more than one thirty-se…
R.246-215-246-215-04410 Installation—Fixed equipment, elevation or sealing (FDA Food Code 4-402.12).
1.5K chars
(1) Except as specified in subsections (2) and (3) of this section, floor-mounted equipment that is not easily movable must be sealed to the floor or elevated on legs that provide at least a six inch (15 cm) clearance between the floor and the equipment.(2) If no part of the floo…
R.246-215-246-215-04500 Equipment—Good repair and proper adjustment (FDA Food Code 4-501.11).
0.7K chars
(1) equipment must be maintained in a state of repair and condition that meets the requirements specified under Part 4, Subpart A and Part 4, Subpart B of this chapter.(2) equipment components such as doors, seals, hinges, fasteners, and kick plates must be kept intact, tight, an…
R.246-215-246-215-04505 Equipment—Cutting surfaces (FDA Food Code 4-501.12).
0.4K chars
Surfaces such as cutting blocks and boards that are subject to scratching and scoring must be resurfaced if they can no longer be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-…
R.246-215-246-215-04510 Equipment—Microwave ovens (FDA Food Code 4-501.13).
0.3K chars
Microwave ovens must meet the safety standards specified in 21 C.F.R. 1030.10 Microwave Ovens.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04510, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04510, filed 1/17/13, effective 5/1/13.]
R.246-215-246-215-04515 Equipment—Warewashing equipment, cleaning frequency (FDA Food Code 4-501.14).
0.7K chars
A warewashing machine; the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths; and drainboards or other equipment used to substitute for drainboards as specified under WAC 246-215-04310 m…
R.246-215-246-215-04520 Equipment—Warewashing machines, manufacturer's operating instructions (FDA Food Code 4-501.15).
0.5K chars
(1) A warewashing machine and its auxiliary components must be operated in accordance with the machine's data plate and other manufacturer's instructions.(2) A warewashing machine's conveyor speed or automatic cycle times must be maintained accurately timed in accordance with man…
R.246-215-246-215-04525 Equipment—Warewashing sinks, use limitation (FDA Food Code 4-501.16).
0.7K chars
(1) A warewashing sink may not be used for handwashing as specified under WAC 246-215-02315.(2) If a warewashing sink is used to wash wiping cloths, wash produce, or thaw food, the sink must be cleaned as specified under WAC 246-215-04515 before and after each time it is used to …
R.246-215-246-215-04530 Equipment—Warewashing equipment, cleaning agents (FDA Food Code 4-501.17).
0.6K chars
When used for warewashing, the wash compartment of a sink, mechanical warewasher, or wash receptacle of alternative manual warewashing equipment as specified under WAC 246-215-04305(3), must contain a wash solution of soap, detergent, acid cleaner, alkaline cleaner, degreaser, ab…
R.246-215-246-215-04535 Equipment—Warewashing equipment, clean solutions (FDA Food Code 4-501.18).
0.2K chars
The wash, rinse and sanitize solutions must be maintained clean.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04535, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04535, filed 1/17/13, effective 5/1/13.]
R.246-215-246-215-04540 Equipment—Manual warewashing equipment, wash solution temperature (FDA Food Code 4-501.19).
0.4K chars
The temperature of the wash solution in manual warewashing equipment must be maintained at not less than 110°F (43°C) or the temperature specified on the cleaning agent manufacturer's label instructions.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-0…
R.246-215-246-215-04545 Equipment—Mechanical warewashing equipment, wash solution temperature (FDA Food Code 4-501.110).
0.7K chars
(1) The temperature of the wash solution in spray-type warewashers that use hot water to sanitize may not be less than:(a) For a stationary rack, single temperature machine, 165°F (74°C);(b) For a stationary rack, dual temperature machine, 150°F (66°C);(c) For a single tank, conv…
R.246-215-246-215-04550 Equipment—Manual warewashing equipment, hot water sanitization temperature (FDA Food Code 4-501.111).
0.3K chars
If immersion in hot water is used for sanitizing in a manual operation, the temperature of the water must be maintained at 171°F (77°C) or above.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04550, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 2…
R.246-215-246-215-04555 Equipment—Mechanical warewashing equipment, hot water sanitization temperatures (FDA Food Code 4-501.112).
0.8K chars
(1) Except as specified in subsection (2) of this section, in a mechanical operation, the temperature of the fresh hot water sanitizing rinse as it enters the manifold may not be more than 194°F (90°C) or less than:(a) For a stationary rack, single temperature machine, 165°F (74°…
R.246-215-246-215-04560 Equipment—Mechanical warewashing equipment, sanitization pressure (FDA Food Code 4-501.113).
0.6K chars
The flow pressure of the fresh hot water sanitizing rinse in a warewashing machine, as measured in the water line immediately downstream or upstream from the fresh hot water sanitizing rinse control valve, must be within the range specified on the machine manufacturer's data plat…
R.246-215-246-215-04565 Equipment—Manual and mechanical warewashing equipment, chemical sanitization—Temperature, pH, concentration, and hardness (FDA Food Code 4-501.114).
2.5K chars
A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under WAC 246-215-04710(3) must meet the requirements specified under WAC 246-215-07220, must be used in accordance with the EPA-registered label use instructions, a…
R.246-215-246-215-04570 Equipment—Manual warewashing equipment, chemical sanitization using detergent-sanitizers (FDA Food Code 4-501.115).
0.5K chars
If a detergent-sanitizer is used to sanitize in a cleaning and sanitizing procedure where there is no distinct water rinse between the washing and sanitizing steps, the agent applied in the sanitizing step must be the same detergent-sanitizer that is used in the washing step.[Sta…
R.246-215-246-215-04575 Equipment—Warewashing equipment, determining chemical sanitizer concentration (FDA Food Code 4-501.116).
0.3K chars
Concentration of the sanitizing solution must be accurately determined by using a test kit or other device.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04575, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04575, filed 1/17/13, effective…
R.246-215-246-215-04580 Utensils and temperature and pressure measuring devices—Good repair and calibration (FDA Food Code 4-502.11).
0.7K chars
(1) utensils must be maintained in a state of repair or condition that complies with the requirements specified under Part 4, Subparts A and B, or must be discarded.(2) food temperature measuring devices must be calibrated in accordance with manufacturer's specifications as neces…
R.246-215-246-215-04585 Utensils and temperature and pressure measuring devices—Single-service and single-use articles, required use (FDA Food Code 4-502.12).
0.5K chars
A food establishment without facilities specified under Part 4, Subparts F and G of this chapter for cleaning and sanitizing kitchenware and tableware must provide only single-use kitchenware, single-service articles, and single-use articles for use by food employees and single-s…
R.246-215-246-215-04590 Utensils and temperature and pressure measuring devices—Single-service and single-use articles, use limitation (FDA Food Code 4-502.13).
0.4K chars
(1) single-service and single-use articles may not be reused.(2) The bulk milk container dispensing tube must be cut on the diagonal leaving no more than one inch protruding from the chilled dispensing head.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-2…
R.246-215-246-215-04595 Utensils and temperature and pressure measuring devices—Shells, use limitation (FDA Food Code 4-502.14).
0.3K chars
Mollusk and crustacea shells may not be used more than once as serving containers.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04595, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04595, filed 1/17/13, effective 5/1/13.]
R.246-215-246-215-04600 Objective—Equipment, food-contact surfaces, nonfood-contact surfaces, and utensils (FDA Food Code 4-601.11).
0.5K chars
(1) equipment, food-contact surfaces, and utensils must be clean to sight and touch.(2) The food-contact surfaces of cooking equipment and pans must be kept free of encrusted grease deposits and other soil accumulations.(3) Nonfood-contact surfaces of equipment must be kept free …
R.246-215-246-215-04605 Objective—Equipment food-contact surfaces and utensils (FDA Food Code 4-602.11).
4.6K chars
(1) equipment, food-contact surfaces, and utensils must be cleaned:(a) Except as specified in subsection (2) of this section, before each use with a different type of raw animal food such as beef, fish, lamb, pork, or poultry;(b) Each time there is a change from working with raw …
R.246-215-246-215-04610 Objective—Cooking and baking equipment (FDA Food Code 4-602.12).
0.6K chars
(1) The food-contact surfaces of cooking and baking equipment must be cleaned at least every twenty-four hours. This section does not apply to hot oil cooking and filtering equipment if it is cleaned as specified under WAC 246-215-04605 (4)(f).(2) The cavities and door seals of m…
R.246-215-246-215-04615 Objective—Nonfood-contact surfaces (FDA Food Code 4-602.13).
0.3K chars
Nonfood-contact surfaces of equipment must be cleaned at a frequency necessary to preclude accumulation of soil residues.[Statutory Authority: RCW 43.20.050 and 43.20.145. WSR 21-01-122, § 246-215-04615, filed 12/15/20, effective 3/1/22; WSR 13-03-109, § 246-215-04615, filed 1/17…
R.246-215-246-215-04620 Methods—Dry cleaning (FDA Food Code 4-603.11).
0.5K chars
(1) If used, dry cleaning methods such as brushing, scraping, and vacuuming may only contact surfaces that are soiled with dry food residues that are not time/temperature control for safety food.(2) Cleaning equipment used in dry cleaning food-contact surfaces may not be used for…
R.246-215-246-215-04625 Methods—Precleaning (FDA Food Code 4-603.12).
0.5K chars
(1) food debris on equipment and utensils must be scraped over a waste disposal unit or garbage receptacle or must be removed in a warewashing machine with a prewash cycle.(2) If necessary for effective cleaning, utensils and equipment must be preflushed, presoaked, or scrubbed w…
R.246-215-246-215-04630 Methods—Loading of soiled items, warewashing machines (FDA Food Code 4-603.13).
0.4K chars
Soiled items to be cleaned in a warewashing machine must be loaded into racks, trays, or baskets or onto conveyors in a position that:(1) Exposes the items to the unobstructed spray from all cycles; and(2) Allows the item to drain.[Statutory Authority: RCW 43.20.050 and 43.20.145…
R.246-215-246-215-04635 Methods—Wet cleaning (FDA Food Code 4-603.14).
0.7K chars
(1) equipment, food-contact surfaces, and utensils must be effectively washed to remove or completely loosen soils by using the manual or mechanical means necessary such as the application of detergents containing wetting agents and emulsifiers; acid, alkaline, or abrasive cleane…