43,809 sections across 2,191 Washington regulatory chapters.
R.296-806-296-806-42018 Follow these requirements for replacing conveyor parts.
0.3K chars
You must make sure replacement conveyor parts are equal to or exceed the manufacturer's specifications.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42018, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 296-806-42018, filed 6/29…
R.296-806-296-806-42020 Follow these requirements for spill guards.
0.5K chars
You must install protective or spill guards wherever conveyors pass next to or over working areas or passageways. These guards must be designed to catch and hold any materials that may become dislodged or fall off.Reference:For specific requirements when conveyors pass over emerg…
R.296-806-296-806-42022 Provide pedestrian overpasses for conveyors.
0.9K chars
(1) You must provide a pedestrian overpass covering the full width of a passageway if one of these conditions exists:(a) The working strand of a conveyor crosses within three feet of floor level.(b) Workers must step over the strand and trough at or below floor level.(2) You must…
R.296-806-296-806-42024 Guard openings to hoppers and chutes.
1.1K chars
(1) You must guard all openings to hoppers, chutes, and elevator-type conveyors to prevent workers from:(a) Falling or stepping into them.(b) Making any kind of bodily contact with conveyors.Note:Grating provided at floor level with no openings larger than two inches (50 mm) that…
R.296-806-296-806-42026 Install guideposts.
0.3K chars
You must install guideposts to direct employees driving trucks, loaders, or other equipment to the pit, hopper, or chute.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42026, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 296-806…
R.296-806-296-806-42027 Belt conveyors.
0.4K chars
You must meet the requirements…in this section:Guard nip points on belt conveyorsWAC 296-806-42028Install emergency stop controllers on overland belt conveyorsWAC 296-806-42030Install belt conveyor overpassesWAC 296-806-42032[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.0…
R.296-806-296-806-42028 Guard nip points on belt conveyors.
0.9K chars
EXEMPTION:This rule does not normally require guards along the conveyor at the point where the belt rides on return rollers, such as return-belt idlers, unless hazardous conditions such as long, tight heavy belts exist.Return-belt idlersThese turn freely and just idle.You must pl…
R.296-806-296-806-42030 Install emergency stop controllers on overland belt conveyors.
0.5K chars
You must install permanent emergency pull cords or similar emergency stop controllers at points where workers are normally stationed along overland belt conveyors.Note:Personnel that patrol overland belt conveyors may use portable emergency stop controllers instead of permanently…
R.296-806-296-806-42032 Install belt conveyor overpasses.
0.4K chars
You must install a pedestrian overpass or underpass along the sides of long overland belt conveyors, where there is the most foot traffic. The distance between overpasses should not exceed three hundred meters or one thousand feet.[Statutory Authority: RCW 49.17.010, 49.17.040, 4…
R.296-806-296-806-42033 Chain converyors.
0.4K chars
You must meet the requirements…in this section:Safeguard chain conveyorsWAC 296-806-42034Guard return strands on chain conveyorsWAC 296-806-42036Guard chain conveyors that are used as a transfer mechanismWAC 296-806-42038[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, …
R.296-806-296-806-42034 Safeguard chain conveyors.
0.3K chars
You must provide safeguards for drive, tail, and idler sprocket pulleys where the chain creates a nip or shear point.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42034, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 296-806-420…
R.296-806-296-806-42036 Guard return strands on chain conveyors.
0.5K chars
(1) You must provide a way to catch and support the ends of a chain that break over a passageway.(2) You must provide a strong enough trough to carry the weight from a broken chain on conveyors when return strands operate within seven feet of the floor.[Statutory Authority: RCW 4…
R.296-806-296-806-42038 Guard chain conveyors that are used as a transfer mechanism.
0.7K chars
You must guard chain conveyors whose moving chains cannot be enclosed without impairing their function by one of the following methods:(1) Distance as required in, make sure safeguarding by distance meets these requirements, WAC 296-806-20056.(2) Personnel barriers.(3) Warning si…
R.296-806-296-806-42039 Elevator conveyors.
0.3K chars
You must meet the requirements…in this section:Prevent material from falling off of elevator conveyorsWAC 296-806-42040[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42039, filed 12/1/15, effective 1/5/16.]
R.296-806-296-806-42040 Prevent material from falling off of elevator conveyors.
0.5K chars
(1) You must install strong guards, screens, or barricades to prevent material from falling in any direction into the shaft way of elevator-type conveyors, except at loading and unloading areas.(2) You must install automatic shaft way gates or suitable barriers at each floor leve…
R.296-806-296-806-42041 Inclined reciprocating conveyors (shakers).
0.3K chars
You must meet the requirements…in this section:Provide protection where employees must load shakersWAC 296-806-42042Provide grating over silo and bunker openings for shuttle conveyorsWAC 296-806-42044[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-…
R.296-806-296-806-42042 Provide protection where employees must load shakers.
0.5K chars
(1) You must provide standard guardrails or snap chains along loading sides of the shaker where personnel must load or unload material. Snap chains must be at least thirty-nine inches high at their lowest point.(2) You must make sure controls are located so the conveyor cannot be…
R.296-806-296-806-42044 Provide grating over silo and bunker openings for shuttle conveyors.
0.5K chars
You must provide grating with openings to match the size of the material being discharged into silos or bunkers. Make sure openings are:(1) Small enough so that workers cannot fall through.(2) Protected by other effective means if the material size requires openings large enough …
R.296-806-296-806-42045 Mobile conveyors.
0.4K chars
You must meet the requirements…in this section:Guard wheels and rails on mobile conveyorsWAC 296-806-42046Prevent hazardous motion on mobile conveyorsWAC 296-806-42048Provide a detector for mobile conveyorsWAC 296-806-42050Provide safe access on mobile conveyorsWAC 296-806-42052[…
R.296-806-296-806-42046 Guard wheels and rails on mobile conveyors.
0.3K chars
You must install sweeps in front of the nip points created by the wheels and rails to deflect objects that could derail the conveyor.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42046, filed 12/1/15, effective 1/5/16; WSR 04-14-02…
R.296-806-296-806-42048 Prevent hazardous motion on mobile conveyors.
0.6K chars
(1) You must make sure mobile conveyors have at least one of the following to prevent hazardous motion:(a) Brakes.(b) Rail clamps.(c) Other position-locking devices.(2) You must provide limit switches that will stop travel when exceeding the design limits of rail-mounted mobile c…
R.296-806-296-806-42050 Provide a detector for mobile conveyors.
0.3K chars
You must provide a detector to stop conveyor movement when the operation creates a danger of running into a stockpile or other obstacle.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42050, filed 12/1/15, effective 1/5/16; WSR 04-14…
R.296-806-296-806-42052 Provide safe access on mobile conveyors.
0.4K chars
You must make sure that access stairways, ladders, and platforms are designed and located to avoid the shear or nip point hazards of the conveyor and moving machinery.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42052, filed 12/1/…
R.296-806-296-806-42053 Push-bar conveyors.
0.2K chars
You must meet the requirements…in this section:Guard pusher-bar conveyorsWAC 296-806-42054[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42053, filed 12/1/15, effective 1/5/16.]
R.296-806-296-806-42054 Guard pusher-bar conveyors.
0.4K chars
You must provide a guard when hazards exist at each of these points:(1) At the discharge point where the bar passes through the bed.(2) Where there is a shear point between the return pusher bar and a frame member.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.0…
R.296-806-296-806-42055 Roller conveyors.
0.4K chars
You must meet the requirements…in this section:Prohibit walking on roller-type conveyorsWAC 296-806-42056Use speed controls for roller and wheel conveyorsWAC 296-806-42058Safeguard belt-driven live roller conveyorsWAC 296-806-42060[Statutory Authority: RCW 49.17.010, 49.17.040, 4…
R.296-806-296-806-42056 Prohibit walking on roller-type conveyors.
0.4K chars
You must prohibit employees from walking on the rolls of roller-type conveyors. Tread plates or other types of walkways can be used between the rollers as a walking surface for operators when performing their duties.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17…
R.296-806-296-806-42058 Use speed controls for roller and wheel conveyors.
0.6K chars
(1) You must avoid safety hazards created by unit or package speeds by one of the following methods:(a) Limiting the length of the sloped run.(b) Using speed retarders or brakes.(c) Other means of providing speed control.(2) You must make sure rollers and wheels are free running …
R.296-806-296-806-42060 Safeguard belt-driven live roller conveyors.
0.8K chars
You must guard belt and roller nip points by one of the following methods:(1) Space load-carrying rollers to prevent access to the belt and roller nip points.(2) Insert rods or plates between the rollers to prevent access to the belt and roller nip points.(3) Use rollers that pop…
R.296-806-296-806-42061 Screw conveyors.
0.2K chars
You must meet the requirements…in this section:Guard screw conveyorsWAC 296-806-42062[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42061, filed 12/1/15, effective 1/5/16.]
R.296-806-296-806-42062 Guard screw conveyors.
0.9K chars
(1) You must enclose the rotating screw to prevent contact with the shear points where it passes the sides of the trough or casing.(2) You must guard screw conveyors requiring an open housing by using one of the following:(a) Make sure safeguarding by distance meets these require…
R.296-806-296-806-42063 Skip hoists.
0.4K chars
You must meet the requirements…in this section:Provide slack-cable switches on hoistsWAC 296-806-42064Block the skip bucket and counterweight guidesWAC 296-806-42066Protect against wire rope coming off sheavesWAC 296-806-42068[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.…
R.296-806-296-806-42064 Provide slack-cable switches on hoists.
0.5K chars
You must provide and arrange slack cable switches to cut power to the drive and set the brake when the skip or counterweight hoisting ropes either:(1) Develop slack; or(2) Lose tension due to sticking in the guides, over travel, or for any other reason.[Statutory Authority: RCW 4…
R.296-806-296-806-42066 Block the skip bucket and counterweight guides.
0.4K chars
You must make sure the skip bucket and counterweight are blocked in their guides when the brake or any part of the drive train between the brake and the drum shaft are being repaired or replaced.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, …
R.296-806-296-806-42068 Protect against wire rope coming off sheaves.
0.3K chars
You must fit all sheaves with sheave guards to prevent the wire rope from coming off under slack cable or similar conditions.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42068, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 296…
R.296-806-296-806-42069 Slat and roller-slat conveyors.
0.2K chars
You must meet the requirements…in this section:Safeguard slat and roller-slat conveyorsWAC 296-806-42070[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42069, filed 12/1/15, effective 1/5/16.]
R.296-806-296-806-42070 Safeguard slat and roller-slat conveyors.
0.7K chars
(1) You must provide either of these safeguards at the tail end of a slat conveyor if the slats are above the centerline of the chain:(a) A guard over the hazardous tail end; or(b) Warning signs if guards are impractical because of material flowing over the tail sprocket.(2) You …
R.296-806-296-806-42071 Towed conveyors.
0.4K chars
You must meet the requirements…in this section:Provide a safe method for disengaging the tow pinWAC 296-806-42072Protect employees from moving carts on towed conveyorsWAC 296-806-42074Provide clearances and warnings for carts on towed conveyorsWAC 296-806-42076Mark projections ab…
R.296-806-296-806-42072 Provide a safe method for disengaging the tow pin.
0.3K chars
You must provide a method for the operator to disengage the tow pin from a conveyor pusher without being in front of the cart.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42072, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 29…
R.296-806-296-806-42074 Protect employees from moving carts on towed conveyors.
0.5K chars
(1) You must make sure runaway carts are unable to exit ramps and enter work areas.(2) You must have a barrier of sufficient strength and height on ramps with pedestrian or traffic aisles to prevent a runaway cart from entering the aisle.(3) You must have signs warning employees …
R.296-806-296-806-42076 Provide clearances and warnings for carts on towed conveyors.
1.2K chars
(1) You must provide clearance space for personnel in all of the following:(a) Between the sides of carts.(b) Between any load overhanging the side of a cart.(c) Any fixed or moving object.(2) You must identify the cart path with floor stripes that are:(a) Parallel to the cart pa…
R.296-806-296-806-42078 Mark projections above the floor.
0.4K chars
You must mark the area around projections above the floor with appropriate diagonal stripes, warning signs, or both.Note:This is especially important if projections above the floor are unpredictable or occur intermittently.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050…
R.296-806-296-806-425 Food processing equipment.
1.3K chars
SummaryIf your specific food processing machine or operation is not listed here, then follow any facilities requirements in this section along with the "Requirements for all machines" found in this chapter, WAC 296-806-200 and 296-806-300.This section applies to:(1) All businesse…
R.296-806-296-806-42502 Provide locks on chamber doors of large air conditioning units.
0.4K chars
You must make sure all door locks on air conditioning unit chambers, that are large enough for employees to enter, can be operated from both inside and outside the chamber.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42502, filed …
R.296-806-296-806-42504 Use proper door locks on rack-type bread coolers.
0.3K chars
You must make sure all door locks can be operated from both inside and outside the bread cooler.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42504, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 296-806-42504, filed 6/29/04, ef…
R.296-806-296-806-42506 Provide see-through panels on fermentation room doors.
0.3K chars
You must provide shatterproof, see-through panels, made of wire glass or plastic, on fermentation room doors.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42506, filed 12/1/15, effective 1/5/16; WSR 04-14-028, § 296-806-42506, file…
R.296-806-296-806-42508 Cover exposed hot pipes.
0.3K chars
You must cover exposed hot (160°F or more) water and steam pipes with insulating material wherever necessary to prevent employee contact.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42508, filed 12/1/15, effective 1/5/16; WSR 04-1…
R.296-806-296-806-42510 Provide extension piping on stationary lubrication fittings.
0.4K chars
You must provide extension piping on stationary lubrication fittings to prevent workers from reaching into the hazardous area when lubricating moving machinery.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42510, filed 12/1/15, eff…
R.296-806-296-806-42512 Provide hoods for pan-washing tanks.
0.4K chars
EXEMPTION:This requirement does not apply to dishwashers or sanitizers used in restaurants or retail establishments.You must provide power-ventilated exhaust hoods over the tank.[Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. WSR 15-24-102, § 296-806-42512, …
R.296-806-296-806-42514 Safeguard proof boxes.
0.6K chars
(1) You must make sure all door locks can be operated from both inside and outside the proof box.(2) You must provide guide rails to center the racks as they enter, pass through, and leave the proof box if pans, boards, or trays may be easily dislodged.Note:Guide rails are not re…