Mine Wants to Bring Electronic Testing Gear Closer to Work

Published Date: 11/17/2026

Notice

Summary

Crimson Oak Grove Resources, LLC wants to change a safety rule at their Oak Grove Mine in Alabama. They’re asking to use special electronic testing gear closer to certain mining areas than current rules allow, promising it’s just as safe. If approved, this could speed up work without costing extra, but everyone has until December 17, 2026, to share their thoughts.

Analyzed Economic Effects

5 provisions identified: 2 benefits, 1 costs, 2 mixed.

Allow specified testing gear within 150 feet

The petitioner asks permission to use certain non-permissible low-voltage or battery-powered electronic testing and diagnostic equipment within 150 feet of pillar workings or longwall faces. Allowed devices are listed (for example, AMS 2140 Machinery Health Analyzer, laptops, oscilloscopes, insulation testers, ultrasonic measuring devices, electronic tachometers) and fault detectors are explicitly not allowed. The equipment must meet IEC 60079-11 or ANSI/UL 60079-11 when commercially available, have IP66 or the highest available IP rating, meet lithium battery standards UL1642 or IEC 62133 when applicable, and be no older than 10 years from manufacture.

Methane limits and detector rules

The equipment may not be used if methane is detected at or above 1.0 percent; if 1.0 percent or more methane is detected while equipment is being used, the equipment must be de-energized immediately and withdrawn to fresh air. All hand-held methane detectors must be MSHA-approved, calibrated or bump-tested before each shift, provide visual and audible warnings at and above 1.0 percent, and methane tests must be made at least 12 inches from the roof, face, ribs and floor before energizing equipment.

Operational restriction during coal production

The petitioner states the subject equipment may not be used when coal production is occurring on the section; all mining on the section must cease before using the equipment. A positive means to prevent mobile equipment from tramming in the same entry or crosscut must be provided and addressed in the mine ventilation plan.

Lithium battery and charging restrictions

Equipment containing lithium batteries must meet UL1642 or IEC 62133 and battery packs must not be disassembled or modified except by the manufacturer. Batteries must be changed out in intake air outside the subject area, replacement batteries may not be brought into the subject area, batteries must not be charged underground, and battery packs showing greater than a 20% performance decrease must not be used.

Inspections, records, training, and EMI/RFI tests

The petition requires a qualified person to examine equipment before taking it underground and at least weekly, with exam results recorded weekly and allowed to be expunged after one year. Equipment must be serviced per manufacturer recommendations and records kept on mine property; equipment may not be used until MSHA initially inspects it and RFI/EMI testing is done with MSHA notified at least 5 working days before testing. All affected miners and qualified persons must receive training on the Petition terms and a training record must be maintained.

Personalized for You

How does this regulation affect your finances?

Personalize government policy and PRIA will tell you what this federal register document means for your household, plus every other regulation we track. PRIA reads each provision against your financial profile to show you exactly what matters to your wallet.

Key Dates

Published Date
Comments Due
11/17/2026
12/17/2026

Department and Agencies

Department
Independent Agency
Agency
Labor Department
Mine Safety and Health Administration
Source: View HTML

Related Federal Register Documents

Previous / Next Documents

Back to Federal Register