27,689 sections across 1,921 District of Columbia regulatory chapters.
12-J7-12-J704 MEANS OF EGRESS
2.6K chars
704 MEANS OF EGRESS Insert new Sections 704.2 and 704.3 to the Existing Building Code to read as follows: 704.2 Use of Exit and Exit Access Enclosures. Exits and exit access corridors shall comply with Section 1018.5 of the Building Code, 12 DCMR A. Exception: Existing exit acces…
12-J7-12-J705 ACCESSIBILITY
2.5K chars
705 ACCESSIBILITY Strike Section 705.2 of the International Existing Building Code in its entirety and insert new Section 705.2 to the Existing Building Code in its place to read as follows: 705.2 Alterations affecting an area containing a primary function. Where an alteration af…
12-J8-12-J801 GENERAL
3.0K chars
801 GENERAL Strike Section 801.1 of the International Existing Building Code in its entirety and insert new Section 801.1 to the Existing Building Code in its place to read as follows: 801.1 Scope. Level 2 alterations as described in Section 504 shall comply with the requirements…
12-J8-12-J804 FIRE PROTECTION
2.0K chars
804 FIRE PROTECTION Strike Section 804.3 of the International Existing Building Code in its entirety and insert new Section 804.3 to the Existing Building Code in its place to read as follows: 804.3 Standpipes. Where the work area includes exits or corridors shared by more than o…
12-J8-12-J805 MEANS OF EGRESS
10.6K chars
805 MEANS OF EGRESS Strike Section 805.3.1.1 of the International Existing Building Code in its entirety and insert new Section 805.3.1.1 to the Existing Building Code in its place to read as follows: 805.3.1.1 Single-exit buildings. Only one exit is required from buildings and s…
12-J9-12-J902 SPECIAL USE AND OCCUPANCY
1.9K chars
902 SPECIAL USE AND OCCUPANCY Strike Section 902.1 of the International Existing Building Code I its entirety and insert new Section 902.1 to the Existing Building Code in its place to read as follows: 902.1 High-rise buildings. Any building having occupied floors more than 75 fe…
12-J9-12-J903 BUILDING ELEMENTS AND MATERIALS
2.3K chars
903 BUILDING ELEMENTS AND MATERIALS Insert new Section 903.4 in the Existing Building Code to read as follows: 903.4 Air-borne sound. Walls, partitions and floor/ceiling assemblies separating dwelling units from each other or from public or service areas shall have a sound transm…
12-J9-12-J904 FIRE PROTECTION
3.9K chars
904 FIRE PROTECTION Strike Section 904.1.1 of the International Existing Building Code in its entirety and insert new Section 904.1.1 to the Existing Building Code in its place to read as follows: 904.1.1 High-rise buildings. In high-rise buildings, work areas shall be provided w…
12-K-A-12-K-A01 A101 - GENERAL
2.0K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A101 GENERAL Strike Section A101.1 of Appendix A in the International Green Constructi…
12-K-A-12-K-A02 A102 - APPLICABILITY AND CONFORMANCE
2.1K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A102 APPLICABILITY AND CONFORMANCE Strike Section A102.2 of Appendix A in the Internat…
12-K-A-12-K-A04 A104 - SITE PROJECT ELECTIVES
6.4K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A104 SITE PROJECT ELECTIVES Strike Section A104.1 (including Subsections 104.1.1 throu…
12-K-A-12-K-A05 A105 - MATERIAL RESOURCE CONSERVATION AND EFFICIENCY
3.8K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A105 MATERIAL RESOURCE CONSERVATION AND EFFICIENCY Strike Section A105.1 in Appendix A…
12-K-A-12-K-A06 A106 - ENERGY CONSERVATION, EFFICIENCY AND EARTH ATMOSPHERIC QUALITY
11.6K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A106 ENERGY CONSERVATION, EFFICIENCY AND EARTH ATMOSPHERIC QUALITY Strike Table A106 i…
12-K-A-12-K-A07 A107 - WATER RESOURCE CONSERVATION AND EFFICIENCY
5.2K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A107 WATER RESOURCE CONSERVATION AND EFFICIENCY Strike Table A107 in Appendix A of the…
12-K-A-12-K-A08 A108 - INDOOR ENVIRONMENTAL QUALITY AND COMFORT
12.7K chars
APPENDIX A PROJECT ELECTIVES Appendix A to the International Green Construction Code is adopted and incorporated into the Green Construction Code as Appendix A with the following modifications. A108 INDOOR ENVIRONMENTAL QUALITY AND COMFORT Strike Table A108 in Appendix A of the I…
12-K1-12-K101 GENERAL
1.7K chars
101 GENERAL Strike Chapter 1 of the International Green Construction Code in its entirety and insert new Chapter 1 in the Green Construction Code in its place to read as follows. 101.1 Scope and intent. Scope and intent of the Green Construction Code shall be governed by Chapter …
12-K10-12-K1000 EXISTING BUILDINGS
1.4K chars
1000 EXISTING BUILDINGS Strike Chapter 10 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246 (May 23, 2014). The Dis…
12-K11-12-K1100 EXISTING BUILDING SITE DEVELOPMENT
1.4K chars
1100 EXISTING BUILDING SITE DEVELOPMENT Strike Chapter 11 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246 (May 23…
12-K12-12-K1200 ASME
1.6K chars
1200 ASME Under the heading “ASME”, in Chapter 12 of the Green Construction Code, insert a new standard reference number ASME/A17.1 2010/CSA B44-10 to read as follows: ASME American Society of Mechanical Engineers, Inc. Three Park Avenue New York, NY 10016-5990 Standard reference…
12-K12-12-K1201 ASHRAE
1.8K chars
1201 ASHRAE Under the heading “ASHRAE”, in Chapter 12 of the International Green Construction Code, strike standard reference number 189.1-2011 in its entirety and insert standard reference number 189.1-2011 in its place to read as follows: ASHRAE American Society of Heating, Ref…
12-K12-12-K1202 ENTERPRISE COMMUNITY PARTNERS
1.7K chars
1202 ENTERPRISE COMMUNITY PARTNERS Insert a new Referenced Standard to Chapter 12 of the Green Construction Code to read as follows: Enterprise Community Partners Enterprise Community Partners, Inc. 70 Corporate Center 11000 Broken Land Parkway Suite 700 Columbia, MD 21044 Standa…
12-K12-12-K1203 EPA
2.3K chars
1203 EPA Under the heading “EPA”, in Chapter 12 of the Green Construction Code, insert the following new Referenced Standards to read as follows: EPA Environmental Protection Agency Ariel Rios Building 1200 Pennsylvania Avenue, NW Washington, D.C. 20460 Standard reference number …
12-K12-12-K1204 ISO
2.4K chars
1204 ISO Under the heading “ISO”, in Chapter 12 of the International Green Construction Code, strike standard reference number 14044-2006 in its entirety and insert in Chapter 12 of the Green Construction Code under subheading “ISO” a new standard reference number 14044-2006 in i…
12-K12-12-K1205 USGBC
1.9K chars
1205 USGBC Insert a new Referenced Standard in Chapter 12 of the Green Construction Code to read as follows: USGBC U.S. Green Building Council 2101 L Street, NW, Suite 500 Washington, D.C. 20037 Standard reference number Title Referenced in code section number LEED-NC 2009 LEED-C…
12-K2-12-K202 DEFINITIONS
5.3K chars
202 DEFINITIONS Insert the following new definitions in Section 202 of the Green Building Code to read as follows: DAYLIT AREA. 1. Under skylights. The area under skylights whose horizontal dimension, in each direction, is equal to the skylight dimension in that direction plus ei…
12-K3-12-K301 GENERAL
1.6K chars
301 GENERAL Strike Chapter 3 of the International Green Construction Code in its entirety and insert new Chapter 3 in the Green Construction Code in its place to read as follows: 301.1 General. The scope of the Green Construction Code, and alternative paths for complying with the…
12-K3-12-K302 GREEN BUILDING ACT REQUIREMENTS
26.6K chars
302 GREEN BUILDING ACT REQUIREMENTS Strike Chapter 3 of the International Green Construction Code in its entirety and insert new Chapter 3 in the Green Construction Code in its place to read as follows: 302.1 Green Building Act of 2006 requirements. An applicant for permits subje…
12-K3-12-K303 ASHRAE 189.1 ADOPTION
12.0K chars
303 ASHRAE 189.1 ADOPTION Strike Chapter 3 of the International Green Construction Code in its entirety and insert new Chapter 3 in the Green Construction Code in its place to read as follows: 303.1 Adoption. ASHRAE 189.1 is adopted and incorporated into the Green Construction Co…
12-K4-12-K401 GENERAL
2.0K chars
401 GENERAL Strike Section 401.2 of the International Green Construction Code in its entirety and insert new Section 401.2 in the Green Construction Code in its place to read as follows: 401.2 Predesign site inventory and assessment. An inventory and assessment of the natural res…
12-K4-12-K402 PRESERVATION OF NATURAL RESOURCES
1.4K chars
402 PRESERVATION OF NATURAL RESOURCES Strike Section 402 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246 (May 23,…
12-K4-12-K403 STORMWATER MANAGEMENT
1.4K chars
403 STORMWATER MANAGEMENT Strike Section 403 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246 (May 23, 2014). The …
12-K4-12-K404 LANDSCAPE IRRIGATION AND OUTDOOR FOUNTAINS
1.4K chars
404 LANDSCAPE IRRIGATION AND OUTDOOR FOUNTAINS Strike Section 404 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246…
12-K4-12-K405 MANAGEMENT OF VEGETATION, SOILS AND EROSION CONTROL
7.3K chars
405 MANAGEMENT OF VEGETATION, SOILS AND EROSION CONTROL Strike Section 405.1 of the International Green Construction Code in its entirety and insert new Section 405.1 in the Green Construction Code in its place to read as follows: 405.1 Soil and water quality protection. Soil and…
12-K4-12-K406 BUILDING SITE WASTE MANAGEMENT
2.6K chars
406 BUILDING SITE WASTE MANAGEMENT Strike Section 406.1 of the International Green Construction Code in its entirety and insert new Section 406.1 in the Green Construction Code in its place to read as follows: 406.1 Building site waste management requirements. Not less than 75 pe…
12-K4-12-K407 TRANSPORTATION IMPACT
1.4K chars
407 TRANSPORTATION IMPACT Strike Section 407 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246 (May 23, 2014). The …
12-K4-12-K408 HEAT ISLAND MITIGATION
2.5K chars
408 HEAT ISLAND MITIGATION Strike Section 408.1 of the International Green Construction Code in its entirety and insert new Section 408.1 in the Green Construction Code in its place to read as follows: 408.1 General. The heat island effect of building and building site developmen…
12-K4-12-K409 SITE LIGHTING
4.4K chars
409 SITE LIGHTING Strike Section 409.1 of the International Green Construction Code in its entirety and insert new Section 409.1 in the Green Construction Code in its place to read as follows: 409.1 Light pollution control. Uplight, light trespass, and glare shall be limited for …
12-K5-12-K503 CONSTRUCTION WASTE MANAGEMENT
3.0K chars
503 CONSTRUCTION WASTE MANAGEMENT Strike Section 503.1 of the International Green Construction Code in its entirety and insert new Section 503.1 in the Green Construction Code in its place to read as follows: 503.1 Construction material and waste management requirements. Not less…
12-K5-12-K504 WASTE MANAGEMENT AND RECYCLING
1.4K chars
504 WASTE MANAGEMENT AND RECYCLING Strike Section 504 of the International Green Construction Code in its entirety without substitution. SOURCE: Final Rulemaking published at 61 DCR 3356 (March 28, 2014 – Part 2); as corrected by Errata Notice published at 61 DCR 5246 (May 23, 20…
12-K5-12-K505 MATERIAL SELECTION
8.2K chars
505 MATERIAL SELECTION Strike Section 505 of the International Green Construction Code in its entirety and insert new Section 505 in the Green Construction Code in its place to read as follows: 505.1 Material selection and properties. Building materials shall conform to Section 5…
12-K5-12-K507 BUILDING ENVELOPE MOISTURE CONTROL
1.9K chars
507 BUILDING ENVELOPE MOISTURE CONTROL Strike Section 507.1 of the International Green Construction Code in its entirety and insert new Section 507.1 in the Green Construction Code in its place to read as follows: 507.1 Moisture control preventative measures. Moisture preventativ…
12-K6-12-K601 GENERAL
1.9K chars
601 GENERAL Strike Section 601.3.1 in the International Green Construction Code in its entirety and insert new Section 601.3.1 in the Green Construction Code in its place to read as follows: 601.3.1 Performance-based compliance. Buildings designed on a performance basis shall com…
12-K6-12-K602 MODELED PERFORMANCE
4.3K chars
602 MODELED PERFORMANCE PATHWAY REQUIREMENTS Strike Section 602.1 and Subsection 602.1.1 of the International Green Construction Code in their entirety and insert new Section 602.1 and Subsection 602.1.1 in the Green Construction Code in their place to read as follows: 602.1 Perf…
12-K6-12-K603 ENERGY METERING, MONITORING AND REPORTING
6.5K chars
ENERGY METERING, MONITORING AND REPORTING Strike Section 603.1 of the International Green Construction Code in its entirety and insert new Section 603.1 in the Green Construction Code in its place to read as follows: 603.1 Scope. The provisions of Section 603 shall only apply to …
12-K6-12-K604 AUTOMATED DEMAND-RESPONSE (AUTO-DR) INFRASTRUCTURE
3.4K chars
604 AUTOMATED DEMAND-RESPONSE (AUTO-DR) INFRASTRUCTURE Strike Section 604.1 of the International Green Construction Code in its entirety and insert new Section 604.1 in the Green Construction Code in its place to read as follows: 604.1 Establishing an open and interoperable autom…
12-K6-12-K605 BUILDING ENVELOPE SYSTEMS
3.0K chars
605 BUILDING ENVELOPE SYSTEMS Strike Section 605.1 of the International Green Construction Code in its entirety and insert new Section 605.1 in the Green Construction Code in its place to read as follows: 605.1 Prescriptive compliance. Where buildings are designed using the presc…
12-K6-12-K606 BUILDING MECHANICAL SYSTEMS
5.8K chars
606 BUILDING MECHANICAL SYSTEMS Strike Section 606.2 of the International Green Construction Code in its entirety without substitution. Strike Section 606.3 of the International Green Construction Code in its entirety and insert new Section 606.3 in the Green Construction Code in…
12-K6-12-K607 BUILDING SERVICE WATER HEATING SYSTEMS
2.2K chars
607 BUILDING SERVICE WATER HEATING SYSTEMS Strike Section 607.2.2 of the International Green Construction Code in its entirety and insert new Section 607.2.2 in the Green Construction Code in its place to read as follows: 607.2.2 Water heater controls for dwelling units. Water he…
12-K6-12-K608 BUILDING ELECTRICAL POWER AND LIGHTING SYSTEMS
4.4K chars
608 BUILDING ELECTRICAL POWER AND LIGHTING SYSTEMS Strike Section 608.4 (including Sections 608.4.1 and 608.4.2) of the International Green Construction Code in its entirety and insert new Section 608.4 in the Green Construction Code in its place to read as follows: 608.4 Exterio…
12-K6-12-K609 SPECIFIC APPLIANCES AND SYSTEMS
3.4K chars
609 SPECIFIC APPLIANCES AND EQUIPMENT Strike Section 609.2 of the International Green Construction Code in its entirety and insert new Section 609.2 in the Green Construction Code in its place to read as follows: 609.2 Permanent appliances and equipment. Appliances and equipment …