18,466 sections across 645 Minnesota regulatory chapters.
R.4620.3569 4620.3569 DECONTAMINATION UNITS.
2.2K chars
4620.3569 DECONTAMINATION UNITS. Subpart 1. General. Procedures for the use of the decontamination unit must be established by the person performing abatement to prevent contamination outside the asbestos work area. A decontamination unit must be used by all persons when exiting …
R.4620.3570 4620.3570 HEPA-FILTERED NEGATIVE PRESSURE.
4.8K chars
4620.3570 HEPA-FILTERED NEGATIVE PRESSURE. Subpart 1. General. The containment must be provided with a HEPA-filter equipped ventilation system. Subp. 2. HEPA-filter equipped negative air requirements. The HEPA-filter negative air machine must be equipped with: A. a calibrated pre…
R.4620.3571 4620.3571 REMOVAL OF ASBESTOS-CONTAINING MATERIAL.
1.1K chars
4620.3571 REMOVAL OF ASBESTOS-CONTAINING MATERIAL. Subpart 1. General. Water to which a surfactant has been added must be used before and during removal of asbestos-containing material to prevent fibers from becoming airborne during asbestos-related work. All asbestos-containing …