19,386 sections across 2,525 Ohio regulatory chapters.
R.3745-570-200 General requirements for infectious waste treatment facilities
13.2K chars
(A) The owner or operator shall conduct all construction and operations at the infectious waste treatment facility in compliance with all applicable authorizing documents.(B) Facility management plan. Unless sodium hypochlorite is exclusively utilized for the treatment of culture…
R.3745-570-201 Approved infectious waste treatment methods
1.0K chars
The owner or operator shall treat infectious waste utilizing only the following approved infectious waste treatment methods:(A) Incineration in accordance with rule 3745-570-202 of the Administrative Code.(B) Autoclaving in accordance with rule 3745-570-203 of the Administrative …
R.3745-570-202 Incineration
5.1K chars
(A) Methodology. The owner or operator using incineration shall conduct treatment of infectious waste in accordance with the following methodologies:(1) Using a multi-chamber incinerator that provides complete combustion of all wastes, excluding metal, glass, and ceramic items.(2…