19,378 sections across 2,525 Ohio regulatory chapters.
R.3701:1-46-37 Calibration or reference sources containing americium-241 or radium-226: requirements for license to manufacture or initially transfer
3.5K chars
An application for a specific license to manufacture or initially transfer calibration or reference sources containing americium-241 or radium-226, for distribution to persons generally licensed under rule 3701:1-46-08 of the Administrative Code, will be approved if:(A) The appli…
R.3701:1-46-38 Calibration or reference sources containing americium-241 or radium-226: labeling of devices
1.7K chars
(A) Each person licensed under rule 3701:1-46-37 of the Administrative Code shall affix to each source, or storage container for the source, a label which shall contain sufficient information relative to safe use and storage of the source and shall include one of the following st…
Calibration or reference sources containing americium-241 or radium-226: leak testing of each source
1.3K chars
Each person licensed under rule 3701:1-46-37 of the Administrative Code shall perform a dry wipe test upon each source containing more than 3.7 kilobecquerels (0.1 microcurie) of americium-241 or radium-226 prior to transferring the source to a general licensee under rule 3701:1-…