19,378 sections across 2,525 Ohio regulatory chapters.
R.3701:1-52-19 Operating and emergency procedures
2.3K chars
(A) The licensee shall have and follow written operating procedures for:(1) Operation of the irradiator, including entering and leaving the radiation room;(2) Use of personnel dosimeters;(3) Surveying the shielding of panoramic irradiators;(4) Monitoring pool water for contaminat…
R.3701:1-52-20 Personnel monitoring
1.3K chars
(A) Irradiator operators shall wear a personnel dosimeter while operating a panoramic irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter processor must be capable of detecting high energy photons in the normal and accident dose ra…
R.3701:1-52-21 Radiation surveys
2.4K chars
(A) A radiation survey of the area outside the shielding of the radiation room of a panoramic irradiator must be conducted with the sources in the exposed position before the facility starts to operate. A radiation survey of the area above the pool for pool irradiators must be co…