4VAC25-40-5270 Measurement of air quantities.
0.4K chars
At least once each week, a certified foreman shall measure the volume of air entering the main intakes and leaving the main returns, the volume of the intake and return of each split, and the volume through the last open crosscuts or other ventilation openings nearest the active …
4VAC25-40-5280 Ventilation of battery-charging and transformer stations.
0.2K chars
Permanently installed battery-charging and transformer stations shall be ventilated by separate splits of air conducted directly to return air courses. Statutory Authority§§ 45.1-161.3 and 45.1-161.294 of the Code of Virginia.
4VAC25-40-5290 Intake air for pumps and compressors.
0.2K chars
Electrically-operated pumps, compressors, and portable substations shall be in intake air. Statutory Authority§§ 45.1-161.3, 45.1-161.294 and 45.1-161.305 of the Code of Virginia.